Related papers: Direct Observation of Broadband Coating Thermal No…
We present design equations for a two-element closely-spaced interferometer for measuring the noise temperature of a uniform sky. Such an interferometer is useful for observing highly diffuse radio sources such as the Milky Way and…
We calculate the thermal noise in half-infinite mirrors containing a layer of arbitrary thickness and depth made of excessively lossy material but with the same elastic material properties as the substrate. For the special case of a thin…
Flat-band (FB) materials have emerged as promising platforms for exploring exotic quantum phases. While numerous candidates have recently been identified through spectroscopic techniques such as angle-resolved photoemission spectroscopy,…
We study the sensitivity limits of a broadband gravitational-waves detector based on dual resonators such as nested spheres. We determine both the thermal and back-action noises when the resonators displacements are read-out with an…
One of the limiting noise sources of ground-based gravitational wave detectors at frequencies below 30 Hz is control-induced displacement noise. Compact laser interferometric sensors are a prime candidate for improved local displacement…
In this letter, we characterize the internal dissipation of coated micro-cantilevers through their mechanical thermal noise. Using a home-made interferometric setup, we achieve a resolution down to 1E-14m/rtHz in the measurement of their…
A new method of probing mechanical losses and comparing the corresponding deposition processes of metallic and dielectric coatings in 1-100 MHz frequency range and cryogenic temperatures is presented. The method is based on the use of…
Accurate thermal modeling of Terminal Test Masses (TTMs) is crucial for optimizing the sensitivity of gravitational wave interferometers like Virgo. In fact, in such gravitational wave detectors even minimal laser power absorption can…
Wavelength calibration is a key factor for high-resolution spectroscopic measurements for precision radial velocities. Hollow-cathode lamps (e.g., ThAr), absorption cells (e.g., iodine cell), dielectric coated Fabry-P\'erot etalons and…
The interrogation of a sensor based on a highly birefringent film irradiated by an incident beam whose polarization is oriented 45o with respect to the normal film axes is shown to display exceptional features and resolve some outstanding…
Coating Brownian noise is the dominant noise term, in a frequency band from a few tens to a few hundreds Hz, for all Earth-bound detectors of gravitational waves. Minimizing such noise is mandatory to increase the visibility distance of…
Our research efforts in displacement measurement interferometry focused on long-term drifts initiated an extended experimental investigation in the interferometric assemblies of our design. We aimed to analyze, characterize and tackle the…
A derivation of the optical axis lenght fluctations due by tilts of the mirrors of the Fabry-Perot cavity of long-baseline interferometers for the detection of gravitational waves in presence of the gravitational field of the earth is…
High finesse optical cavities of current interferometric gravitational-wave detectors are significantly limited in sensitivity by laser quantum noise and coating thermal noise. The thermal noise is associated with internal energy…
Features of thermal transport in multilayered porous silicon nanostructures are considered. Such nanostructures were fabricated by electrochemical etching of monocrystalline Si substrates by applying periodically changed current density.…
We demonstrate a thermal infrared (IR) detector based on an ultra-high-quality-factor (Q) whispering-gallery-mode (WGM) microtoroidal silica resonator, and investigate its performance to detect IR radiation at 10 micron wavelength. The…
An analysis is given of thermoelastic noise (thermal noise due to thermoelastic dissipation) in finite sized test masses of laser interferometer gravitational-wave detectors. Finite-size effects increase the thermoelastic noise by a modest…
The Sagnac Interferometer has historically been used for detecting non-reciprocal phenomena, such as rotation. We demonstrate an apparatus in which this technique is employed for high resolution measurements of the Magneto-Optical Polar…
Stimulated Brillouin scattering was recently observed in nanoscale silicon waveguides. Surprisingly, thermally-driven photon-phonon conversion in these structures had not yet been reported. Here, we inject an optical probe in a suspended…
We apply noise thermometry to characterize charge and thermoelectric transport in single InAs nanowires (NWs) at a bath temperature of 4.2 K. Shot noise measurements identify elastic diffusive transport in our NWs with negligible…