English

Temperature induced optical scatter changes in titania-germania coatings

Instrumentation and Methods for Astrophysics 2025-10-08 v2 Optics

Abstract

Titania doped with tantala is the high index material (high n) for the optical coatings used in LIGO and Virgo and its thermal noise limits LIGO/Virgo observations of astrophysical sources. In this paper, we study temperature induced changes to optical scatter of a multilayer highly reflective coating comprised of silica (low n) and titania doped with germania (high n) as a potential candidate to reduce coating thermal noise in ground-based observatories operating at room temperature. We observe that the scatter measured at 8 degree in a small region is low, with a median starting BRDF of 1.1×107str11.1 \times 10^{-7}\,\mathrm{str}^{-1} increasing to 1.2×106str11.2 \times 10^{-6}\,\mathrm{str}^{-1} through annealing. The results presented here show the potential of adopting titania doped with germania coatings for future upgrades to LIGO and Virgo and as a pathfinder coating for Cosmic Explorer, a next-generation detector.

Keywords

Cite

@article{arxiv.2508.20043,
  title  = {Temperature induced optical scatter changes in titania-germania coatings},
  author = {D. P. Kapasi and T. Counihan and J. R. Smith and S. Tait and G. Billingsley},
  journal= {arXiv preprint arXiv:2508.20043},
  year   = {2025}
}

Comments

4 pages, 2 figures, conference proceedings for GR24/Amaldi16 meeting