Related papers: Low noise cryogenic electronics: preamplifier conf…
TES-based bolometer and microcalorimeter arrays with thousands of pixels are under development for several space-based and ground-based applications. A linear detector response and low levels of cross talk facilitate the calibration of the…
Cold electron bolometers have shown their suitability for use in modern fundamental physical experiments. Fabrication and measurements of the samples with cold-electron bolometers integrated into coplanar antennas are performed in this…
Sensitive microwave detectors are critical instruments in radioastronomy, dark matter axion searches, and superconducting quantum information science. The conventional strategy towards higher-sensitivity bolometry is to nanofabricate an…
The aim of the SELENDIS project within the EDELWEISS collaboration is to observe single $e^- h^+$ pairs in lightweight (3.3 g) cryogenic germanium bolometers with charge and phonon readout at biases up to $\sim 100$ V. These devices are…
In high-sensitivity bolometers and calorimeters, the photon absorption often occurs at a finite distance from the temperature sensor to accommodate antennas or avoid the degradation of superconducting circuitry exposed to radiation. As a…
Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…
We present the design and characterisation of a low-noise, resonant input transimpedance amplified photodetector. The device operates at a resonance frequency of $90 \,\textrm{MHz}$ and exhibits an input referred current noise of…
Sensitive n-type and p-type germanium thermistors were fabricated by the melt doping technique and by the neutron transmutation doping (NTD) technique, respectively, aiming at a use for the cryogenic thermal detector, or bolometer of Tokyo…
Optomechanical transduction harnesses the interaction between optical fields and mechanical motion to achieve sensitive measurement of weak mechanical quantities with inherently low noise. Lithium niobate combines low optical loss, strong…
Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments…
Low-frequency qubit control wires require non-trivial thermal anchoring and low-pass filtering. The resulting electron temperature serves as a quality benchmark for these signal lines. In this technical note, we make use of a primary…
We present a study of thin-film molybdenum resistors for NbN electronics operating at cryogenic temperatures. The key step is the 0.5-1.5 keV ion cleaning-activation of NbN before Mo deposition which allows to obtain a high-quality Mo/NbN…
We developed an impedance bridge that operates at cryogenic temperatures (down to 60 mK) and in perpendicular magnetic fields up to at least 12 T. This is achieved by mounting a GaAs HEMT amplifier perpendicular to a printed circuit board…
Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise…
A digital frequency multiplexing (DfMUX) system has been developed and used to tune large arrays of transition edge sensor (TES) bolometers read out with SQUID arrays for mm-wavelength cosmology telescopes. The DfMUX system multiplexes the…
We demonstrate a radio-frequency parametric amplifier that exploits the gate-tunable quantum capacitance of an ultra high mobility two dimensional electron gas (2DEG) in a GaAs heterostructure at cryogenic temperatures. The prototype…
A high accuracy and high sensitivity system architecture is proposed for the read-out circuit of electrical impedance tomography system-on-chip. The switched ratiometric technique is applied in the proposed architecture. The proposed system…
The cryogenic performance of GaN-based HEMTs (high-electron-mobility transistors) is systematically investigated by the direct current (DC) and low-frequency noise (LFN) characteristics within the temperature (T) range from 300 K to 4.2 K.…
An electron-on-helium qubit is a promising physical platform for quantum information technologies. Among all the "blueprints" for the qubit realization, a hybrid Rydberg-spin qubit seems to be a promising one towards quantum computing using…
The paper describes a radio frequency (RF) spectrometer for 14N nuclear quadrupole resonance (NQR) spectroscopy that uses a detector coil cooled to 77 K to maximize measurement sensitivity. The design uses a minimally-intrusive network of…