English
Related papers

Related papers: Low noise cryogenic electronics: preamplifier conf…

200 papers

This paper presents an analytical model to quantify the measured noise in a cryogenic bolometer readout circuit. The model includes the contributions from the bias resistors and sensor resistors, voltage and current noise of amplifier, and…

Instrumentation and Detectors · Physics 2022-12-07 V. Vatsa , A. Reza , A. Mazumdar , M. S. Pose , S. Mallikarjunachary , V. Nanal , R. G. Pillay , S. Ramakrishnan , A. Shrivastava

We implemented a low noise current preamplifier for the readout of resistive bolometers. We tested the apparatus on thermometer resistances ranging from 10 Ohm to 500 Mohm. The use of current preamplifier overcomes constraints introduced by…

Instrumentation and Detectors · Physics 2009-10-31 D. Yvon , V. Sushkov , R. Bernard , J. L. Bret , B. Cahan , O. Cloue , O. Maillard , B. Mazeau , J. P. Passerieux , B. Paul , C. Veyssiere

The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We describe here the development of Ge…

The SPLENDOR Collaboration studies novel narrow-gap semiconductors and engineered a substrate agnostic detector platform to achieve $\mathcal{O}$(meV) energy sensitivity designed for low mass dark matter searches. This was achieved using…

Instrumentation and Detectors · Physics 2025-10-03 Jadyn Anczarski , Owen Andrews , Taylor Aralis , Caleb Fink , Noah Kurinsky , Arran Phipps , Aditi Pradeep , Betty A. Young

We demonstrate strong negative electrothermal feedback accelerating and linearizing the response of a thermal kinetic inductance detector (TKID). TKIDs are a proposed highly multiplexable replacement to transition-edge sensors and measure…

An amplifier has been designed for optimal use of position sensitive thermal neutron detectors using the principle of resistive charge division. The important points in this optimization are: high counting rates and good spatial resolution.…

Instrumentation and Detectors · Physics 2009-11-13 Patrick Van Esch , Thomas Gahl , Bruno Guerard

Since the invention of the bolometer, its main design principles relied on efficient light absorption into a low-heat-capacity material and its exceptional thermal isolation from the environment. While the reduced thermal coupling to its…

Mesoscale and Nanoscale Physics · Physics 2018-09-26 D. K. Efetov , R. -J. Shiue , Y. Gao , B. Skinner , E. Walsh , H. Choi , J. Zheng , C. Tan , G. Grosso , C. Peng , J. Hone , K. C. Fong , D. Englund

We present the noise performance of High Electron Mobility Transistors (HEMT) developed by CNRS-C2N laboratory. Various HEMT's gate geometries with 2 pF to 230 pF input capacitance have been studied at 4 K. A model for both voltage and…

Instrumentation and Detectors · Physics 2019-12-05 A. Juillard , J. Billard , D. Chaize , J-B Filippini , D. Misiak , L. Vagneron , A. Cavanna , Q. Dong , Y. Jin , C. Ulysse , A. Bounab , X. de la Broise , C. Nones , A. Phipps

Radiation sensors based on the heating effect of the absorbed radiation are typically relatively simple to operate and flexible in terms of the input frequency. Consequently, they are widely applied, for example, in gas detection, security,…

Mesoscale and Nanoscale Physics · Physics 2020-10-02 R. Kokkoniemi , J. -P. Girard , D. Hazra , A. Laitinen , J. Govenius , R. E. Lake , I. Sallinen , V. Vesterinen , P. Hakonen , M. Möttönen

We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a…

Low capacitance, large volume, high purity germanium (HPGe) radiation detectors have been successfully employed in low-background physics experiments. However, some physical processes may not be detectable with existing detectors whose…

Instrumentation and Detectors · Physics 2015-12-18 Paul Barton , Mark Amman , Ryan Martin , Kai Vetter

We have developed two analytical models to describe the performance of cryogenic microcalorimeters and bolometers. One of the models is suitable to describe Transition Edge Sensor (TES) detectors with an integrated absorber, the other is…

Instrumentation and Detectors · Physics 2009-11-11 J. W. Appel , M. Galeazzi

Indium-Arsenide (InAs) nanowire field-effect transistors (NWFETs) are promising platforms for high-speed, low-power nanoelectronics operating at cryogenic conditions, relevant for quantum information processing. We use selective area growth…

The readout of transition-edge sensor (TES) bolometers with a large multiplexing factor is key for the next generation Cosmic Microwave Background (CMB) experiment, Polarbear-2, having 7,588 TES bolometers. To enable the large arrays, we…

Cryogenic low noise amplifiers based on high electron mobility transistors (HEMTs) are widely used in applications such as radio astronomy, deep space communications, and quantum computing, and the physical mechanisms governing the…

Mesoscale and Nanoscale Physics · Physics 2021-11-03 Alexander Y. Choi , Iretomiwa Esho , Bekari Gabritchidze , Jacob Kooi , Austin J. Minnich

We report on the solution optimized for characterizing SNSPDs by rejecting electromagnetic interference from various sources. The proposed readout method enhances measurement stability and enables reliable device characterization at low…

Instrumentation and Detectors · Physics 2026-01-07 Sangbaek Lee , Whitney Armstrong , Maximo DiPreta , Jacob Dulya , Valentine Novosad , Tomas Polakovic

We present ultra-thin silicon membrane thermocouple bolometers suitable for fast and sensitive detection of low levels of thermal power and infrared radiation at room temperature. The devices are based on 40 nm-thick strain tuned single…

Parametric amplifiers have become a workhorse in superconducting quantum computing, however research and development of these devices has been hampered by inconsistent, and sometimes misleading noise performance characterization…

Quantum Physics · Physics 2023-12-25 M. Malnou , T. F. Q. Larson , J. D. Teufel , F. Lecocq , J. Aumentado

Electro-thermal coupling in semiconductor bolometers is known to create nonlinearities in transient detector response, particularly when such detectors are biased outside of their ideal regions (i.e. past the turnover point in their IV…

Instrumentation and Detectors · Physics 2022-09-07 Samantha Lynn Stever , François Couchot

We have designed and characterized a cryogenic amplifier for use in $^3$He NMR spectrometry. The amplifier, with a power consumption of $\sim 2.5$ mW, works at temperatures down to 4~K. It has a hi-impedance input for measuring a signal…

Instrumentation and Detectors · Physics 2019-04-24 V. V. Zavjalov , A. M. Savin , P. J. Hakonen