English
Related papers

Related papers: SDE-based Monte Carlo dose calculation for proton …

200 papers

Monte Carlo (MC) is generally considered as the most accurate dose calculation tool for particle therapy. However, a proper description of the beam particles kinematics is a necessary input for a realistic simulation. Such a description can…

We have determined the depth-dose curve, the penetration range, and the water equivalent ratio (WER), for proton beams of clinical energies in cortical bone, by means of a detailed and accurate simulation that combines molecular dynamics…

Medical Physics · Physics 2024-09-18 Ana María Zamora-Vinaroz , Pablo de Vera , Isabel Abril , Rafael Garcia-Molina

Single minibeams of protons, $^{4}$He, $^{12}$C and $^{16}$O in water were modeled with Geant4, and their dose distributions were parameterized with double-Gauss-Rutherford (DGR) functions. Dose distributions from arrays of 16 parallel…

Medical Physics · Physics 2024-12-30 Savva Savenkov , Alexandr Svetlichnyi , Igor Pshenichnov

Improving effective treatment plans in carbon ion therapy, especially for targeting radioresistant tumors located in deep seated regions while sparing normal tissues, depends on a precise and computationally efficient dose calculation…

Medical Physics · Physics 2025-06-25 Fulya Halıcılar , Metin Arık

Proton therapy's full potential is limited by uncertainties that prevent optimal dose distribution. Monitoring techniques can reduce these uncertainties and enable adaptive treatment planning. Spatiotemporal Emission Reconstruction from…

The interplay between the beam delivery time structure and the patient motion makes 4D dose calculation (4DDC) important when treating moving tumors with intensity modulated proton therapy. 4DDC based on phase sorting of a 4DCT suffers from…

Medical Physics · Physics 2023-10-13 Ivar Bengtsson , Erik Engwall , Albin Fredriksson , Lars Glimelius

To improve the quality of cancer treatment with protons, a translation of X-ray Computed Tomography (CT) images into a map of the proton stopping powers needs to be more accurate. Proton stopping powers determined from CT images have…

Particle physics simulations are the cornerstone of nuclear engineering applications. Among them radiotherapy (RT) is crucial for society, with 50% of cancer patients receiving radiation treatments. For the most precise targeting of tumors,…

Machine Learning · Computer Science 2021-09-10 Oscar Pastor-Serrano , Zoltán Perkó

This article examines the critical role of fast Monte Carlo dose calculations in advancing proton therapy techniques, particularly in the context of increasing treatment customization and precision. As adaptive radiotherapy and other…

Medical Physics · Physics 2024-04-24 Jason Holmes , Hongying Feng , Lian Zhang , Michael Fix , Steve B. Jiang , Wei Liu

In this paper we investigate, with a detailed Monte-Carlo simulation based on Geant4, the novel approach [Nucl. Instrum. Methods A588 (2008) 457] to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used…

Medical Physics · Physics 2011-09-23 M. Lenti , M. Veltri

Accurate dose calculation is vitally important for proton therapy. Pencil beam (PB) model-based dose calculation is fast but inaccurate due to the approximation when dealing with inhomogeneities. Monte Carlo (MC) dose calculation is the…

The major advantage of proton therapy over conventional radiotherapy is the dose deposition pattern, enabling precise coverage of the tumour volume while sparing nearby healthy tissues. However, accurate control of the proton beam range…

Medical Physics · Physics 2025-04-01 Magdalena Kołodziej

Accurate 3D dose calculation for Pencil Beam Scanning Proton Therapy (PBSPT) is typically performed with Monte Carlo (MC) engines, but their runtimes limit adaptive workflows and repeated evaluations. Current deep-learning proton dose…

Medical Physics · Physics 2026-02-19 Mikołaj Stryja , Danny Lathouwers , Zoltán Perkó

Arrays of minibeams of protons and $^{12}$C in tissue-like media were modeled with Geant4 toolkit. A set of beam energies was used in simulations to provide a Spead-out Bragg peak (SOBP) extended by 6 cm in depth for protons as well as for…

Medical Physics · Physics 2024-09-23 I. A. Pshenichnov , U. A. Dmitrieva , S. D. Savenkov , A. O. Svetlichnyi

In this work, the standard CsI(Tl) scintillator was used to determine the characteristics of a proton beam. By irradiating the scintillator with a proton beam, it was able to subsequently measure the emitted light using a spectrometer. This…

Purpose: To develop a Monte Carlo (MC) therapeutic dose calculation toolkit of a recently released ring gantry linac in Geant4 (Version 10.7) for secondary dose validation of radiotherapy plan. Methods: For the Halcyon (Varian Medical…

Medical Physics · Physics 2022-10-04 Ruirui Liu , Zhen Ji , Xiandong Zhao , Tianyu Zhao , Abhishek Sethi , Daren Sawkey , Bin Cai

An essential component in proton radiotherapy is the algorithm to calculate the radiation dose to be delivered to the patient. The most common dose algorithms are fast but they are approximate analytical approaches. However their level of…

Medical Physics · Physics 2015-05-20 Pablo P Yepes , Dragan Mirkovic , Phillip J Taddei

Purpose: In this study, we present the creation of an anthropomorphic, head and neck, nuclear medicine phantom and its characterization for the validation of a Monte Carlo, SPECT image based, Iodine-131 RPT dosimetry workflow. Methods: 3D…

Purpose: To enhance an in-house graphic-processing-unit (GPU) accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning…

Purpose: To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen…