English
Related papers

Related papers: Fermilab PIP-II CDS and CM Cryogenic Controls Syst…

200 papers

The large scientific projects present new technological challenges, such as the distributed control over a communication network. In particular, the middleware EPICS is the most extended communication standard in particle accelerators. The…

Systems and Control · Computer Science 2014-06-17 J. Jugo , M. Eguiraun , I. Badillo , I. Arredondo , D. Piso

The injection control system of Hefei Light Source (HLS) storage ring is a subsystem of the upgraded HLS control system, which is based upon EPICS. Three programmable logic controllers (PLCs) are used as device controllers, which control…

Accelerator Physics · Physics 2007-05-23 Gongfa Liu , Jingyi Li , Weimin Li , Chuan Li , Kaihong Li , Lei Shang

Fermilab's Superconducting RF Beam Test Facility currently under construction will produce electron beams capable of damaging the acceleration structures and the beam line vacuum chambers in the event of an aberrant accelerator pulse. The…

Accelerator Physics · Physics 2012-10-01 A. Warner , L. Carmichael , M. Church , R. Neswold

The Accelerator Control System at Fermilab has evolved to enable this relatively large control system to be encapsulated into a "box" such as a laptop. The goal was to provide a platform isolated from the "online" control system. This…

This paper presents verification and implementation methods that have been developed for the design of the BrainScaleS-2 65nm ASICs. The 2nd generation BrainScaleS chips are mixed-signal devices with tight coupling between full-custom…

Hardware Architecture · Computer Science 2020-03-26 Andreas Grübl , Sebastian Billaudelle , Benjamin Cramer , Vitali Karasenko , Johannes Schemmel

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely…

The warm front end of the PIP2IT accelerator, assem-bled and commissioned at Fermilab, consists of a 15 mA DC, 30 keV H- ion source, a 2 m long Low Energy Beam Transport (LEBT) line, and a 2.1 MeV, 162.5 MHz CW RFQ, followed by a 10 m long…

From simple physical systems to full production lines, numerical models could be used to minimize downtime and to optimize performances. In this article, the system of interest is the SPIRAL2 (Syst\`eme de Production d'Ions RAdioactifs en…

Fine pixel CCD (FPCCD) is one of the candidate sensor technologies for the vertex detector used for experiments at the International Linear Collider (ILC). FPCCD vertex detector is supposed to be cooled down to -40 degree for improvement of…

Instrumentation and Detectors · Physics 2017-03-10 Yasuhiro Sugimoto , Keisuke Fujii , Takahiro Fusayasu , Katsuyu Kasami , Tohru Tsuboyama

The Warm Front End (WFE) of the Proton Improvement Plan II Injector Test at Fermilab has been constructed to its full length. It includes a 15-mA DC, 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT) with a switching dipole…

The innermost part of the ATLAS experiment will be a pixel detector containing around 1750 individual detector modules. A detector control system (DCS) is required to handle thousands of I/O channels with varying characteristics. The main…

Instrumentation and Detectors · Physics 2014-11-18 S. Kersten , M. Imhaeuser , P. Kind , H. Burckhart , B. Hallgren , G. Hallewell , V. Vacek

We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The…

Radio frequency cryogenic switches are a critical enabling technology for quantum information science for both calibration and high throughput testing of samples. Traditionally, solenoid-based switches have been used [1,2], but a transition…

Quantum Physics · Physics 2025-01-08 Lafe Spietz , Adam Sirois , Nathan Flowers-Jacobs , Steve Waltman , Samuel Benz , Peter Hopkins

We have developed a cryogenic platform for the control and readout of spin qubits that comprises a high density of dc and radio frequency sample interconnects based on a set of coupled printed circuit boards. The modular setup incorporates…

Mesoscale and Nanoscale Physics · Physics 2015-09-24 J. I. Colless , D. J. Reilly

The cryogenic system for the Spallation Neutron Source (SNS) is designed by Jefferson Laboratory (JLab) personnel and is based on the existing JLab facility. Our task is to use the JLab control system design [2] as much as practical while…

Accelerator Physics · Physics 2014-11-18 W. H. Strong , P. A. Gurd , J. D. Creel , B. S. Bevins

An optical link system is being developed for the ATLAS Liquid Argon Calorimeter Phase-II upgrade. The optical link system is responsible for transmit the data of over 182 thousand detector channels from 1524 Front-End Boards (FEBs) through…

Instrumentation and Detectors · Physics 2020-08-03 B. Deng , C. Liu , D. Gong , X. Huang , S. Hou , T. Liu , H. Sun , L. Zhang , W. Zhang , J. Ye

The Advanced Photon Source is now in its fifth year of routine beam production. The EPICS-based [1] control system has entered the phase in its life cycle where new control algorithms must be implemented under increasingly stringent…

Accelerator Physics · Physics 2007-05-23 D. A. Dohan

A robust cryogenic infrastructure in form of a wired, thermally optimized dilution refrigerator is essential for present and future solid-state based quantum processors. Here, we engineer an extensible cryogenic setup, which minimizes…

Integrable optics is an innovation in particle accelerator design that provides strong nonlinear focusing while avoiding parametric resonances. One promising application of integrable optics is to overcome the traditional limits on…

Accelerator Physics · Physics 2017-03-20 Jeffrey Eldred , Alexander Valishev

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While…

‹ Prev 1 4 5 6 7 8 10 Next ›