English
Related papers

Related papers: CHESS Compact Wiggler construction report

200 papers

Following the successful completion and testing of the sCCU-type undulator with 28mm period, we have designed, prototyped, constructed and bench tested another sCCU-type undulator with a much shorter 19mm-period magnetic structure.…

Instrumentation and Detectors · Physics 2025-01-07 Alexander Temnykh , Ivan Temnykh

Magnetic design proposed for a damping ring (DR) is based on second generation HTS cabling technology applied to the DC windings with a yoke and mu-metal-shimmed pole to achieve ~2T high-quality field within a 86 mm gap and 32-40 cm period.…

Accelerator Physics · Physics 2012-10-16 A. Mikhailichenko , A. V. Smirnov

Following successful proof-of-concept experiments, we constructed compact varying-gap undulator with Hydraulic-Assist Driver. The 1.5m long undulator features a pure permanent magnet structure, period of 28.4 mm and a minimum gap of 6.75mm.…

Instrumentation and Detectors · Physics 2020-05-20 Alexander Temnykh , Ivan Temnykh

Although the so-called magnetic geometrical factor, $Bl$, of a Kibble balance does not appear in the Kibble equations, it offers the precision link between electrical and mechanical quantities and furthers a quasi-quantum traceability path…

Instrumentation and Detectors · Physics 2024-09-06 Yongchao Ma , Nanjia Li , Weibo Liu , Kang Ma , Wei Zhao , Songling Huang , Shisong Li

The design of the permanent magnet system for the new Quantum Electro-Mechanical Metrology Suite (QEMMS) is described. The QEMMS, developed at the National Institute of Standards and Technology (NIST), consists of a Kibble balance, a…

Instrumentation and Detectors · Physics 2019-12-30 Rafael R. Marangoni , Darine Haddad , Frank Seifert , Leon S. Chao , David B. Newell , Stephan Schlamminger

The magnet system is one of the key elements of a watt balance. For the new watt balance currently under construction at the National Institute of Standards and Technology, a permanent magnet system was chosen. We describe the detailed…

Instrumentation and Detectors · Physics 2014-12-25 Frank Seifert , Alireza Panna , Shisong Li , Bing Han , Leon Chao , Austin Cao , Darine Haddad , Heeju Choi , Lori Haley , Stephan Schlamminger

The Compact Muon Solenoid (CMS) is a general-purpose detector designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive featuresinclude a 4 T superconducting solenoid with 6 m diameter by 12.5 m long…

An experiment with short prototypes of helical undulators, comprised of longitudinally magnetized helices made from a single piece of a rare-earth magnet, is described. Wire electrical discharge machining (WEDM) in combination with a flat…

Accelerator Physics · Physics 2025-08-04 Nezah Balal , Eberhard Bamberg , Vladimir L. Bratman , Eyal Magory

Design, fabrication and assembly of a novel fast-cycling accelerator magnet is presented. A short-sample magnet is powered with a single-turn HTS cable capable to carry 80 kA current at 20 K and generate 1.75 T field in a 40 mm magnet gap.…

Accelerator Physics · Physics 2018-07-04 H. Piekarz , Jamie Blowers , Steven Hays , Vladimir Shiltsev

Metglas 2705M is a low-cost commercially-available, high-permeability Cobalt-based magnetic alloy, provided as a 5.08-cm wide and 20.3-$\mu$m thick ribbon foil. We present an optimized construction technique for single-shell, large-scale…

Atomic Physics · Physics 2011-07-14 S. Malkowski , R. Adhikari , B. Hona , C. Mattie , D. Woods , H. Yan , B. Plaster

Eugene Wigner predicted long ago that when the Coulomb interactions between electrons become much stronger than their kinetic energy, electrons crystallize into a closely packed lattice. A variety of two-dimensional systems have shown…

Mesoscale and Nanoscale Physics · Physics 2025-12-05 Yen-Chen Tsui , Minhao He , Yuwen Hu , Ethan Lake , Taige Wang , Kenji Watanabe , Takashi Taniguchi , Michael P. Zaletel , Ali Yazdani

Magnetic fields are a standard tool in the toolbox of every physicist, and are required for the characterization of materials, as well as the polarization of spins in nuclear magnetic resonance or electron paramagnetic resonance…

Instrumentation and Detectors · Physics 2021-09-01 C. Adambukulam , V. K. Sewani , H. G. Stemp , S. Asaad , M. T. Mądzik , A. Morello , A. Laucht

We design and demonstrate a compact, robust and simple to assemble and tune permanent magnet suitable for NMR relaxometry measurements of microfluidic flows. Soft-magnetic stainless steel plates, incorporated inside the magnet airgap, are…

Applied Physics · Physics 2023-01-25 Dmytro Polishchuk , Han Gardeniers

We have developed and constructed the field cage of a prototype Time Projection Chamber for research and development studies for a detector at the International Linear Collider. This prototype has an inner diameter of 72 cm and a length of…

Instrumentation and Detectors · Physics 2011-03-28 Ties Behnke , Klaus Dehmelt , Ralf Diener , Lea Hallermann , Takeshi Matsuda , Volker Prahl , Peter Schade

Stiffness variation and real-time position feedback are critical for any robotic system but most importantly for active and wearable devices to interact with the user and environment. Currently, for compact sizes, there is a lack of…

Robotics · Computer Science 2021-03-08 Yongkang Jiang , Junlin Ma , Diansheng Chen , Jamie Paik

We investigate the chiral properties of QCD in presence of a magnetic background field and in the low temperature regime, by lattice numerical simulations of N_f = 2 QCD. We adopt a standard staggered discretization, with a pion mass around…

High Energy Physics - Lattice · Physics 2011-07-04 Massimo D'Elia , Francesco Negro

Permanent magnets with yokes are widely used in the watt and joule balances to measure the Planck constant for the forthcoming redefinition of the unit of mass, the kilogram. Recently, a permanent magnet system has been in consideration for…

Instrumentation and Detectors · Physics 2016-10-12 Qiang You , Jinxin Xu , Zhengkun Li , Shisong Li

The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by…

Instrumentation and Detectors · Physics 2016-06-02 V. I. Klyukhin , N. Amapane , A. Ball , B. Curé , A. Gaddi , H. Gerwig , M. Mulders , V. Calvelli , A. Hervé , R. Loveless

Three-dimensional MEMS magnetometers with use of residual stresses in thin multilayers cantilevers are presented. Half-loop cantilevers based on Lorentz-force deflection convert magnetic flux in changes, thanks to piezoresistive transducers…

Other Computer Science · Computer Science 2008-02-22 M. El Ghorba , N. André , S. Sobieski , J. -P. Raskin

We optimised the magnetic field homogeneity of two canonical designs for mobile microfluidic NMR applications: two parallel magnets with an air gap and a modified Halbach array. Along with the influence of the sample length, general design…

Applied Physics · Physics 2021-03-26 Yannick Klein , Leon Abelmann , Han Gardeniers
‹ Prev 1 2 3 10 Next ›