English
Related papers

Related papers: Photocathode characterisation for robust PICOSEC M…

200 papers

For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good…

A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an…

Instrumentation and Detectors · Physics 2018-07-16 M. M. Aggarwal , Z. Ahammed , S. Aiola , J. Alme , T. Alt , W. Amend , A. Andronic , V. Anguelov , H. Appelshäuser , M. Arslandok , R. Averbeck , M. Ball , G. G. Barnaföldi , E. Bartsch , R. Bellwied , G. Bencedi , M. Berger , N. Bialas , P. Bialas , L. Bianchi , S. Biswas , L. Boldizsár , L. Bratrud , P. Braun-Munzinger , M. Bregant , C. L. Britton , E. J. Brucken , H. Caines , A. J. Castro , S. Chattopadhyay , P. Christiansen , L. G. Clonts , T. M. Cormier , S. Das , S. Dash , A. Deisting , S. Dittrich , A. K. Dubey , R. Ehlers , M. Engel , F. Erhardt , N. B. Ezell , L. Fabbietti , U. Frankenfeld , J. J. Gaardhøje , C. Garabatos , P. Gasik , Á. Gera , P. Ghosh , S. K. Ghosh , P. Glässel , O. Grachov , A. Grein , T. Gunji , H. Hamagaki , G. Hamar , J. W. Harris , P. Hauer , J. Hehner , E. Hellbär , H. Helstrup , T. E. Hilden , B. Hohlweger , M. Ivanov , M. Jung , D. Just , E. Kangasaho , R. Keidel , B. Ketzer , S. A. Khan , S. Kirsch , T. Klemenz , S. Klewin , A. G. Knospe , M. Kowalski , L. Kumar , R. Lang , R. Langoy , L. Lautner , F. Liebske , J. Lien , C. Lippmann , H. M. Ljunggren , W. J. Llope , S. Mahmood , T. Mahmoud , R. Majka , P. Malzacher , A. Marín , C. Markert , S. Masciocchi , A. Mathis , A. Matyja , M. Meres , D. L. Mihaylov , D. Miskowiec , J. Mitra , T. Mittelstaedt , T. Morhardt , J. Mulligan , R. H. Munzer , K. Münning , M. G. Munhoz , S. Muhuri , H. Murakami , B. K. Nandi , H. Natal da Luz , C. Nattrass , T. K. Nayak , R. A. Negrao De Oliveira , M. Nicassio , B. S. Nielsen , L. Oláh , A. Oskarsson , J. Otwinowski , K. Oyama , G. Paić , R. N. Patra , V. Peskov , M. Pikna , L. Pinsky , M. Planinic , M. G. Poghosyan , N. Poljak , F. Pompei , S. K. Prasad , C. A. Pruneau , J. Putschke , S. Raha , J. Rak , J. Rasson , V. Ratza , K. F. Read , A. Rehman , R. Renfordt , T. Richert , K. Røed , D. Röhrich , T. Rudzki , R. Sahoo , S. Sahoo , P. K. Sahu , J. Saini , B. Schaefer , J. Schambach , S. Scheid , C. Schmidt , H. R. Schmidt , N. V Schmidt , H. Schulte , K. Schweda , I. Selyuzhenkov , N. Sharma , D. Silvermyr , R. N. Singaraju , B. Sitar , N. Smirnov , S. P. Sorensen , F. Sozzi , J. Stachel , E. Stenlund , P. Strmen , I. Szarka , G. Tambave , K. Terasaki , A. Timmins , K. Ullaland , A. Utrobicic , D. Varga , R. Varma , A. Velure , V. Vislavicius , S. Voloshin , B. Voss , D. Vranic , J. Wiechula , S. Winkler , J. Wikne , B. Windelband , C. Zhao

A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast…

Instrumentation and Detectors · Physics 2018-06-08 Qiang Cao , Xin Li , Liwei Wang , Jie Kuang , Yonggang Wang , Cheng Li

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven 'EIC HRPPDs' was manufactured in early…

The concept and subsequent experimental verification of the proportionality between pulse amplitude and detector transit time for microchannel plate detectors is presented. This discovery has led to considerable improvement in the overall…

Quantum Physics · Physics 2009-11-13 Victor D. Irby

We present a comprehensive characterization of the LAPPD Gen-II, a large-area microchannel-plate photomultiplier tube (MCP-PMT) equipped with a capacitively coupled sensing (readout) electrode. Two detector variants with different…

Instrumentation and Detectors · Physics 2025-12-03 S. Korpar , R. Dolenec , F. Grijalva , A. Lozar , A. Kodrič , P. Križan , S. Parashari , R. Pestotnik , A. Seljak , D. Žontar

This article presents a detector system consisting of three components, a CMOS imaging array, a gaseous-detector structure with a Micromegas layout and a UV-photon sensitive CsI reflective photocathode. All three elements have been…

A graphene-optimized silicon carbide PIN detector was fabricated and its radiation tolerance under X-ray irradiation of 160 keV was evaluated. Its electrical properties, charge collection performance and time resolution of beta-particles…

Instrumentation and Detectors · Physics 2026-04-23 Zhenyu Jiang , Congcong Wang , Jingxuan He , Yi Zhan , Yingjie Huang , Xiyuan Zhang , Xin Shi

The key parameters of Cherenkov Correlated Timing (CCT) detectors are discussed. Measurements of radiator geometry, optical properties of radiator and coupling materials, and photon detector timing performance are presented.

The Electron-ion collider in China (EicC) is a proposed future electron-ion collider designed to achieve a high luminosity, with a center-of-mass energy ranging from 15 to 20 GeV. Excellent particle identification (PID) with extensive…

Instrumentation and Detectors · Physics 2026-05-25 Xin Li , Yuxiang Zhao , Yutie Liang , Xu Sun

The design of a Ring Imaging CHerenkov (RICH) detector for the identification of high momentum particles at the future Electron Ion Collider (EIC) is extremely challenging by using current technology. Compact collider setups impose to…

We report on a novel calibration method of gaseous detectors using an internal \ce{^{37}Ar} source. The \ce{^{37}Ar} is a fast-decaying and low-energy calibration source that provides a mono-energetic peak of 2.82 keV. A gaseous…

Instrumentation and Detectors · Physics 2025-05-20 Wenming Zhang , Yuanchun Liu , Ke Han , Shaobo Wang , Xiaopeng Zhou , Xunan Guo

The water Cherenkov detector array (WCDA) is one of the key detectors in the large high altitude air shower observatory (LHAASO), which is proposed for very high gamma ray source survey. In WCDA, there are more than 3000 photomultiplier…

Instrumentation and Detectors · Physics 2018-06-26 Shengzhi Zhou , Lei Zhao , Yuxiang Guo , Ruoshi Dong , Boyu Cheng , Jiajun Qin , Sifan Qian , Shubin Liu , Qi An

The testing and quality assurance of cryogenic superconducting detectors is a time- and labor-intensive process. As experiments deploy increasingly larger arrays of detectors, new methods are needed for performing this testing quickly.…

Instrumentation and Methods for Astrophysics · Physics 2025-05-27 K. R. Ferguson , A. N. Bender , N. Whitehorn , P. S. Barry , T. W. Cecil , K. R. Dibert , E. S. Martsen

A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector…

Instrumentation and Detectors · Physics 2023-07-19 Kensuke Yamamoto , Sei Ban , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi

TORCH is a time-of-flight detector designed to perform particle identification over the momentum range 2$-$10 GeV/c for a 10 m flight path. The detector exploits prompt Cherenkov light produced by charged particles traversing a quartz plate…

Detecting the topology and direction of low-energy nuclear and electronic recoils is broadly desirable in nuclear and particle physics, with applications in coherent elastic neutrino-nucleus scattering, astrophysical neutrino measurements,…

Instrumentation and Detectors · Physics 2024-12-31 Majd Ghrear , Alasdair G. McLean , Hima B. Korandla , Ferdos Dastgiri , Neil J. C. Spooner , Sven E. Vahsen

The aim of the presented work is the development of single-stage amplification resistive Micro Pattern Gas Detectors (MPGD) based on Micromegas technology with the following characteristics: ability to efficiently operate up to 10…

This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of…

Instrumentation and Detectors · Physics 2021-07-07 M. Jadhav , W. Armstrong , I. Cloet , S. Joosten , S. M. Mazza , J. Metcalfe , Z. -E. Meziani , H. F. -W. Sadrozinski , B. Schumm , A. Seiden