English
Related papers

Related papers: Photocathode characterisation for robust PICOSEC M…

200 papers

A high spatial resolution tracking system was setup with the Micro-mesh gaseous structure (Micromegas) detectors in order to study the muon tomographic imaging technique for nuclear threat detection. 6 layers of 90 mm $\times$ 90 mm…

Instrumentation and Detectors · Physics 2022-09-12 Liu Cheng-Ming , Wen Qun-Gang , Zhang Zhi-Yong , Huang Guang-Shun

The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO)…

Instrumentation and Detectors · Physics 2024-06-28 A. Galindo-Tellez , V. Sharyy , C. -H. Sung , M. Follin , L. Cappellugola , S. Curtoni , M. Dupont , C. Morel , D. Breton , J. Maalmi , D. Yvon

Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout…

Within the ATTRACT FASTPIX project, a monolithic pixel sensor demonstrator chip has been developed in a modified 180 nm CMOS imaging process technology, targeting sub-nanosecond timing precision for single ionising particles. It features a…

We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates…

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

The next generation of gaseous photon detectors is requested to overcome the limitations of the available technology, in terms of resolution and robustness. The quest for a novel photocathode, sensitive in the far vacuum ultra violet…

As part of the Phase II upgrade program, the Compact Muon Solenoid (CMS) detector will incorporate a new timing layer designed to measure minimum ionizing particles (MIPs) with a time resolution of $\sim$30 ps. Precision timing will…

Instrumentation and Detectors · Physics 2018-11-27 Olmo Cerri

We describe a novel gaseous detector concept for heavy-ion tracking and imaging: the Optical Parallel-Plate Avalanche Counter (O-PPAC). The detector consists of two thin parallel-plate electrodes separated by a small (typically 3 mm) gap…

Instrumentation and Detectors · Physics 2018-10-17 Marco Cortesi , Yassid Ayyada , John Yurkon

Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon…

Instrumentation and Detectors · Physics 2020-04-22 Spencer R. Klein

The Large High Altitude Air Shower Observatory is in the R&D phase, in which the Water Cherenkov Detector Array is an important part. The signals of Photo-Multiplier Tubes would vary from single photo electron to 4000 photo electrons, and…

Instrumentation and Detectors · Physics 2019-07-09 Lei Zhao , Weihao Wu , Jianfeng Liu , Yu Liang , Jiajun Qin , Li Yu , Shubin Liu , Qi An

The TORCH time-of-flight detector is designed to provide particle identification in the momentum range 2-10 GeV/c over large areas. The detector exploits prompt Cherenkov light produced by charged particles traversing a 10 mm thick quartz…

IceCube is a cubic-kilometer scale neutrino telescope located at the geographic South Pole. The detector utilizes the extremely transparent Antarctic ice as a medium for detecting Cherenkov radiation from neutrino interactions. As a result…

Instrumentation and Methods for Astrophysics · Physics 2019-08-22 Hrvoje Dujmović , Minjin Jeong , Christoph Tönnis

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…

Instrumentation and Detectors · Physics 2017-06-02 M. Dragicevic , M. Friedl , J. Hrubec , H. Steininger , A. Gädda , J. Härkönen , T. Lampén , P. Luukka , T. Peltola , E. Tuominen , E. Tuovinen , A. Winkler , P. Eerola , T. Tuuva , G. Baulieu , G. Boudoul , L. Caponetto , C. Combaret , D. Contardo , T. Dupasquier , G. Gallbit , N. Lumb , L. Mirabito , S. Perries , M. Vander Donckt , S. Viret , C. Bonnin , L. Charles , L. Gross , J. Hosselet , D. Tromson , L. Feld , W. Karpinski , K. Klein , M. Lipinski , G. Pierschel , M. Preuten , M. Rauch , M. Wlochal , M. Aldaya , C. Asawatangtrakuldee , K. Beernaert , D. Bertsche , C. Contreras-Campana , G. Eckerlin , D. Eckstein , T. Eichhorn , E. Gallo , J. Garay Garcia , K. Hansen , M. Haranko , A. Harb , J. Hauk , J. Keaveney , A. Kalogeropoulos , C. Kleinwort , W. Lohmann , R. Mankel , H. Maser , G. Mittag , C. Muhl , A. Mussgiller , D. Pitzl , O. Reichelt , M. Savitskyi , P. Schütze , V. Sola , S. Spannagel , R. Walsh , A. Zuber , H. Biskop , P. Buhmann , M. Centis-Vignali , E. Garutti , J. Haller , M. Hoffmann , R. Klanner , T. Lapsien , M. Matysek , A. Perieanu , Ch. Scharf , P. Schleper , A. Schmidt , J. Schwandt , J. Sonneveld , G. Steinbrück , B. Vormwald , J. Wellhausen , M. Abbas , C. Amstutz , T. Barvich , Ch. Barth , F. Boegelspacher , W. De Boer , E. Butz , M. Casele , F. Colombo , A. Dierlamm , B. Freund , F. Hartmann , S. Heindl , U. Husemann , A. Kornmeyer , S. Kudella , Th. Muller , H. J. Simonis , P. Steck , M. Weber , Th. Weiler , T. Kiss , F. Siklér , T. Tölyhi , V. Veszprémi , P. Cariola , D. Creanza , M. De Palma , G. De Robertis , L. Fiore , M. Franco , F. Loddo , G. Sala , L. Silvestris , G. Maggi , S. My , G. Selvaggi , S. Albergo , G. Cappello , S. Costa , A. Di Mattia , F. Giordano , R. Potenza , M. A. Saizu , A. Tricomi , C. Tuve , E. Focardi , M. E. Dinardo , S. Fiorendi , S. Gennai , S. Malvezzi , R. A. Manzoni , D. Menasce , L. Moroni , D. Pedrini , P. Azzi , N. Bacchetta , D. Bisello , M. Dall'Osso , N. Pozzobon , M. Tosi , L. Alunni Solestizi , M. Biasini , G. M. Bilei , C. Cecchi , B. Checcucci , D. Ciangottini , L. Fanò , C. Gentsos , M. Ionica , R. Leonardi , E. Manoni , G. Mantovani , S. Marconi , V. Mariani , M. Menichelli , A. Modak , A. Morozzi , F. Moscatelli , D. Passeri , P. Placidi , V. Postolache , A. Rossi , A. Saha , A. Santocchia , L. Storchi , D. Spiga , K. Androsov , P. Azzurri , G. Bagliesi , A. Basti , T. Boccali , L. Borrello , F. Bosi , R. Castaldi , M. Ceccanti , M. A. Ciocci , R. Dell'Orso , S. Donato , G. Fedi , A. Giassi , M. T. Grippo , F. Ligabue , G. Magazzu , P. Mammini , F. Mariani , E. Mazzoni , A. Messineo , A. Moggi , F. Morsani , F. Palla , F. Palmonari , A. Profeti , F. Raffaelli , A. Ragonesi , A. Rizzi , A. Soldani , P. Spagnolo , R. Tenchini , G. Tonelli , A. Venturi , P. G. Verdini , D. Abbaneo , I. Ahmed , E. Albert , G. Auzinger , G. Berruti , J. Bonnaud , J. Daguin , A. D'Auria , S. Detraz , O. Dondelewski , B. Engegaard , F. Faccio , N. Frank , K. Gill , A. Honma , A. Kornmayer , A. Labaza , F. Manolescu , I. McGill , S. Mersi , S. Michelis , A. Onnela , M. Ostrega , S. Pavis , A. Peisert , J. -F. Pernot , P. Petagna , H. Postema , K. Rapacz , C. Sigaud , P. Tropea , J. Troska , A. Tsirou , F. Vasey , B. Verlaat , P. Vichoudis , L. Zwalinski , F. Bachmair , R. Becker , D. di Calafiori , B. Casal , P. Berger , L. Djambazov , M. Donega , C. Grab , D. Hits , J. Hoss , G. Kasieczka , W. Lustermann , B. Mangano , M. Marionneau , P. Martinez Ruiz del Arbol , M. Masciovecchio , M. Meinhard , L. Perozzi , U. Roeser , A. Starodumov , V. Tavolaro , R. Wallny , D. Zhu , K. Bösiger , L. Caminada , F. Canelli , V. Chiochia , A. de Cosa , C. Galloni , T. Hreus , B. Kilminster , C. Lange , R. Maier , J. Ngadiuba , D. Pinna , P. Robmann , S. Taroni , Y. Yang , W. Bertl , K. Deiters , W. Erdmann , R. Horisberger , H. -C. Kaestli , D. Kotlinski , U. Langenegger , B. Meier , T. Rohe , S. Streuli , P. -H. Chen , C. Dietz , F. Fiori , U. Grundler , W. -S. Hou , R. -S. Lu , M. Moya , J. -F. Tsai , Y. M. Tzeng , D. Cussans , J. Goldstein , M. Grimes , D. Newbold , P. Hobson , I. D. Reid , G. Auzinger , R. Bainbridge , P. Dauncey , G. Hall , T. James , A. -M. Magnan , M. Pesaresi , D. M. Raymond , K. Uchida , T. Durkin , K. Harder , C. Shepherd-Themistocleous , M. Chertok , J. Conway , R. Conway , C. Flores , R. Lander , D. Pellett , F. Ricci-Tam , M. Squires , J. Thomson , R. Yohay , K. Burt , J. Ellison , G. Hanson , M. Olmedo , W. Si , B. R. Yates , A. Dominguez , R. Bartek , B. Bentele , J. P. Cumalat , W. T. Ford , F. Jensen , A. Johnson , M. Krohn , S. Leontsinis , T. Mulholland , K. Stenson , S. R. Wagner , A. Apresyan , G. Bolla , K. Burkett , J. N. Butler , A. Canepa , H. W. K. Cheung , D. Christian , W. E. Cooper , G. Deptuch , G. Derylo , C. Gingu , S. Grünendahl , S. Hasegawa , J. Hoff , J. Howell , M. Hrycyk , S. Jindariani , M. Johnson , F. Kahlid , S. Kwan , C. M. Lei , R. Lipton , R. Lopes De Sá , T. Liu , S. Los , M. Matulik , P. Merkel , S. Nahn , A. Prosser , R. Rivera , B. Schneider , G. Sellberg , A. Shenai , K. Siehl , L. Spiegel , N. Tran , L. Uplegger , E. Voirin , D. R. Berry , X. Chen , L. Ennesser , A. Evdokimov , C. E. Gerber , S. Makauda , C. Mills , I. D. Sandoval Gonzalez , J. Alimena , L. J. Antonelli , B. Francis , A. Hart , C. S. Hill , N. Parashar , J. Stupak , D. Bortoletto , M. Bubna , N. Hinton , M. Jones , D. H. Miller , X. Shi , P. Baringer , A. Bean , S. Khalil , A. Kropivnitskaya , D. Majumder , E. Schmitz , G. Wilson , A. Ivanov , R. Mendis , T. Mitchell , N. Skhirtladze , R. Taylor , I. Anderson , D. Fehling , A. Gritsan , P. Maksimovic , C. Martin , K. Nash , M. Osherson , M. Swartz , M. Xiao , J. G. Acosta , L. M. Cremaldi , S. Oliveros , L. Perera , D. Summers , K. Bloom , D. R. Claes , C. Fangmeier , R. Gonzalez Suarez , J. Monroy , J. Siado , E. Bartz , Y. Gershtein , E. Halkiadakis , S. Kyriacou , A. Lath , K. Nash , M. Osherson , S. Schnetzer , R. Stone , M. Walker , S. Malik , S. Norberg , J. E. Ramirez Vargas , M. Alyari , J. Dolen , A. Godshalk , C. Harrington , I. Iashvili , A. Kharchilava , D. Nguyen , A. Parker , S. Rappoccio , B. Roozbahani , J. Alexander , J. Chaves , J. Chu , S. Dittmer , K. McDermott , N. Mirman , A. Rinkevicius , A. Ryd , E. Salvati , L. Skinnari , L. Soffi , Z. Tao , J. Thom , J. Tucker , M. Zientek , B. Akgün , K. M. Ecklund , M. Kilpatrick , T. Nussbaum , J. Zabel , P. D'Angelo , W. Johns , K. Rose

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors…

Instrumentation and Detectors · Physics 2019-09-04 Wolfgang Hennig , Vincent Thomas , Shawn Hoover , Olivier Delaune

This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…

Time and charge measurements over a large dynamic range from 1 Photo Electron (P.E.) to 4000 P.E. are required for the Water Cherenkov Detector Array (WCDA), which is one of the key components in the Large High Altitude Air Shower…

Instrumentation and Detectors · Physics 2019-09-26 Yu Liang , Lei Zhao , Yuxiang Guo , Jiajun Qin , Yunfang Yang , Boyu Cheng , Shubin Liu , Qi An

The development of high-performance photocathodes is a key challenge for future accelerator and particle physics applications. In this paper photocathode growth through molecular beam epitaxy is introduced as a promising technique to obtain…

Instrumentation and Detectors · Physics 2013-10-11 Junqi Xie , Marcel Demarteau , Robert Wagner

In the new era of HL-LHC experiments, fast-timing detectors are emerging as critical tools for background rejection. Typical requirements include a temporal hit resolution of about 50 ps, a spatial resolution of around 12 $\mu$m, and…

Motivated by the stringent requirements of the Upstream Pixel (UP) tracker in the LHCb Upgrade II and the Inner Tracking detector (ITK) of the Circular Electron Positron Collider, the COFFEE series of pixel sensor chips have been developed…

‹ Prev 1 8 9 10 Next ›