The key parameters of Cherenkov Correlated Timing (CCT) detectors are discussed. Measurements of radiator geometry, optical properties of radiator and coupling materials, and photon detector timing performance are presented.
@article{arxiv.hep-ex/9508008,
title = {The Cherenkov Correlated Timing Detector: Materials, Geometry and Timing Constraints},
author = {D. Aronstein and T. Bergfeld and D. Horton and M. Palmer and M. Selen and G. Thayer and V. Boyer and K. Honscheid and H. Kichimi and Y. Sugaya and H. Yamaguchi and Y. Yoshimura and S. Kanda and S. Olsen and K. Ueno and N. Tamura and K. Yoshimura and C. Lu and D. Marlow and C. Mindas and E. Prebys and P. Pomianowski},
journal= {arXiv preprint arXiv:hep-ex/9508008},
year = {2009}
}
Comments
Presented at the RICH95 workshop, Uppsala, Sweden, June/95. M. Selen corresponding author ([email protected]). 4 pages with 3 figures. LaTex source files and postscript figures compressed and uuencoded below. ***** Replaced to add acknowledgements only, other content unchanged *****