Related papers: Precision measurements on Si-
For high-bias operation devices such as silicon carbide (SiC) power devices, early detection of failure mechanisms is essential to ensure reliability. This requires a method to map high electric fields with high spatial resolution, which…
The Extreme ultraviolet Imaging Spectrometer (EIS) on board the Hinode spacecraft has been operating since 2006, returning high resolution data in the 170-212 and 246-292 A wavelength regions. EIS has four slit options, with the narrow 1"…
In this work the inhomogeneous (zero-phonon line) and homogeneous line widths, and one projection of the permanent electric dipole moment change for the Ce 4f-5d transition in Y_2SiO_5 were measured in order to investigate the possibility…
We have measured electron impact ionization (EII) for Fe 7+ from the ionization threshold up to 1200 eV. The measurements were performed using the TSR heavy ion storage ring. The ions were stored long enough prior to measurement to remove…
Dopants in silicon have been studied for many decades using optical and electron spin resonance (ESR) spectroscopy. Recently, new features have been observed in the spectra of dopants in isotopically enriched 28Si since the reduced…
Electron density diagnostics based on a line intensity ratio of Si X are applied to the X-ray spectra of Procyon, $\alpha$ Cen A$&$B, Capella and $\epsilon$ Eri measured with the Low Energy Transmission Grating Spectrometer (LETGS) combined…
The Saturated Absorption Spectroscopy (SAS) was performed to measure the hyperfine energy splittings of rubidium 5P$_{1/2}$ excited state using a homemade external-cavity diode laser (ECDL) operating at 795 nm. Any nonlinearities associated…
Longstanding problems in the comparison of very accurate hyperfine-shift measurements to theory were partly overcome by precise measurements on few-electron highly-charged ions. Still the agreement between theory and experiment is…
Unique spectroscopic possibilities open up if a laser beam interacts with relativistic lithium-like ions stored in the heavy ion ring accelerator SIS300 at the future Facility for Antiproton and Ion Research FAIR in Darmstadt, Germany. At a…
Because of a luminosity of up to five orders of magnitude larger than at LEP, electroweak precision measurements at the FCC-ee -- the Future Circular Collider with electron-positron beams -- would provide improvements by orders of magnitude…
We report a precise measurement of hyperfine constants in the $\rm{D_1} $ line ($ \rm {5\,P_{1/2}} $ state) of the two stable isotopes of Rb. The motivation for the work is to try and resolve discrepant values that exists in the literature.…
We demonstrate an efficient control of $^{29}$Si nuclear spin orientation for specific lattice sites near $^{31}$P donors in silicon crystals at temperatures below 1 K and in high magnetic field of 4.6 T. Excitation of the forbidden…
We describe the first precision measurement of the electron's electric dipole moment (eEDM, $d_e$) using trapped molecular ions, demonstrating the application of spin interrogation times over 700 ms to achieve high sensitivity and stringent…
Quasi-elastic (QEL) scattering measurements have been performed using $^{28}$Si projectile off a $^{90}$Zr target at energies around the Coulomb barrier. A Bayesian analysis within the framework of coupled channels (CC) calculations is…
Using data samples with an integrated luminosity of 22.42 fb$^{-1}$ collected by the BESIII detector operating at the BEPCII storage ring, we measure the cross sections of the $e^{+}e^{-}\rightarrow\etaJ/\psi$ process at center-of-mass…
Spontaneous decays of small, hot silver cluster anions Ag$_{n}$, $n=4-7$ have been studied using one of the rings of the Double ElectroStatic Ion Ring ExpEriment (DESIREE). Observation of these decays over very long time scales is possible…
We present an all-electron calculation of the hyperfine parameters for conduction electrons in Si, showing that: (i) all parameters scale linearly with the spin density at a $^{29}$Si site; (ii) the isotropic term is over 30 times larger…
We improve by a factor of 4-20 the energy accuracy of the strongest soft X-ray transitions of Fe XVII ions by resonantly exciting them in an electron beam ion trap with a monochromatic beam at the P04 beamline of the PETRA III synchrotron…
The hyperfine structure splittings are determined for the lowest bound state in the positron-helium ion $e^{+}[^3$He$(2^3S)]$ and $e^{+}[^4$He$(2^3S)]$. In particular, we have fond that for the $e^{+}[{}^3$He$(2^3S)]$ ion one can observe…
Hyperfine spectra of $^\text{27-32}$Al ($Z=13$) have been measured at the ISOLDE-CERN facility via collinear laser spectroscopy using the $3s^23p\ ^2\text{P}^\text{o} _{3/2}\rightarrow 3s^24s\ ^2\text{S}_{1/2}$ atomic transition. For the…