English
Related papers

Related papers: Capacitive coupling study of the HERD SCD prototyp…

200 papers

Hybrid silicon pixel detectors are currently used in the innermost tracking system of the Compact Muon Solenoid (CMS) experiment. Radiation tolerance up to fluences expected for a few years of running of the Large Hadron Collider (LHC) has…

Instrumentation and Detectors · Physics 2011-10-07 Gemma Tinti

3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…

In this study, we developed a new proton detector system called CATCH, which was designed for a scattering experiment involving a $\Sigma$ hyperon and a proton (J-PARC E40). CATCH is a cylindrical detector system covering an inner target…

Instrumentation and Detectors · Physics 2022-03-14 Y. Akazawa , N. Chiga , N. Fujioka , S. H. Hayakawa , R. Honda , M. Ikeda , K. Matsuda , K. Miwa , Y. Nakada , T. Nanamura , S. Ozawa , T. Shiozaki , H. Tamura , H. Umetsu

The CMS experiment at the LHC includes a hybrid silicon pixel detector for the reconstruction of charged tracks and of the interaction vertices. The barrel region consists of n-in-n sensors with 100X150 um^2 cell size processed on diffusion…

The InSb/CdTe heterojunction structure, characterized by low effective mass and high electron mobility, exhibits interfacial energy band bending, leading to the Rashba spin-orbit coupling effect and nonreciprocal transport, which makes its…

Applied Physics · Physics 2025-01-10 Xiaoxiao Ma , Zhenghang Zhi , Weijie Deng , Tianxin Li , Qianchun Weng , Xufeng Kou , Wei Lu

We applied a recently developed fiber coupling technique to superconducting single photon detectors (SSPDs). As the detector area of SSPDs has to be kept as small as possible, coupling to an optical fiber has been either inefficient or…

Optics · Physics 2011-09-28 S. N. Dorenbos , R. W. Heeres , E. F. C Driessen , V. Zwiller

Generally, a superconducting nanowire single-photon detector (SNSPD) is composed of wires with a typical width of ~100 nm. Recent studies have found that superconducting strips with a micrometer-scale width can also detect single photons.…

Instrumentation and Detectors · Physics 2021-04-28 Guang-Zhao Xu , Wei-Jun Zhang , Li-Xing You , Jia-Min Xiong , Xing-Qu Sun , Hao Huang , Xin Ou , Yi-Ming Pan , Chao-Lin Lv , Hao Li , Zhen Wang , Xiao-Ming Xie

When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT)…

Silicon single-photon detectors (SPDs) are the key devices for detecting single photons in the visible wavelength range. Here we present high detection efficiency silicon SPDs dedicated to the generation of multiphoton entanglement based on…

We characterize the response of a novel 250 $\mu$m thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable,…

Charge multiplication (CM) in p$^+$n epitaxial silicon pad diodes of 75, 100 and 150 $\upmu$m thickness at high voltages after proton irradiation with 1 MeV neutron equivalent fluences in the order of $10^{16}$ cm$^{-2}$ was studied as an…

Instrumentation and Detectors · Physics 2014-11-21 Jörn Lange , Julian Becker , Eckhart Fretwurst , Robert Klanner , Gunnar Lindström

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future…

Instrumentation and Methods for Astrophysics · Physics 2025-04-30 Kenneth W. Lin , Abby Bault , Armin Karcher , Julien Guy , Stephen E. Holland , William F. Kolbe , Peter E. Nugent

With a total area of 210 squaremeters and about 15000 single silicon modules the silicon strip tracker of the CMS experiment at the LHC will be the largest silicon strip detector ever built. While the performance of the individual…

Instrumentation and Detectors · Physics 2019-08-14 Katja Klein

A Scintillator Deposited CCD (SDCCD) is a wide-band X-ray detector consisting of a CCD and a scintillator directly attached to each other. We assembled the newly developed SDCCD that the scintillator CsI(Tl) is below the fully depleted CCD.…

Instrumentation and Methods for Astrophysics · Physics 2010-10-01 Hiroshi Tsunemi , Shutaro Ueda , Kazuo Shigeyama , Koji Mori , Shoichi Aoyama , Shin'ichiro Takagi

MIDAS (MIcrostrip Detector Array System) is a compact silicon tracking telescope for charged particles emitted at small angles in intermediate energy photonuclear reactions. It was realized to increase the angular acceptance of the DAPHNE…

The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV,…

Instrumentation and Detectors · Physics 2019-05-08 A. C. Abusleme Hoffman , G. Parès , T. Fritzsch , M. Rothermund , H. Jansen , K. Krüger , F. Sefkow , A. Velyka , J. Schwandt , I. Perić , L. Emberger , C. Graf , A. Macchiolo , F. Simon , M. Szalay , N. van der Kolk , H. Abramowicz , Y. Benhammou , O. Borysov , M. Borysova , A. Joffe , S. Kananov , A. Levy , I. Levy , G. Eigen , R. Bugiel , S. Bugiel , M. Firlej , T. A. Fiutowski , M. Idzik , J. Moroń , K. P. Świentek , P. Terlecki , P. Brückman de Renstrom , B. Turbiarz , T. Wojtoń , L. K. Zawiejski , E. Firu , V. Ghenescu , A. T. Neagu , T. Preda , I. Boyko , Yu. Nefedov , A. Rymbekova , A. Sapronov , G. Shelkov , A. Zhemchugov , A. Ruiz-Jimeno , I. Vila , E. Fullana , J. Fuster , P. Gomis Lopez , M. Perelló , M. A. Villarejo , M. Vos , J. Alozy , N. Alipour Tehrani , D. Arominski , R. Ballabriga Sune , F. Boyer , E. Brondolin , M. Buckland , M. Campbell , D. Dannheim , K. Dette , F. Duarte Ramos , N. Egidos Plaja , K. Elsener , A. Fiergolski , C. Fuentes Rojas , C. Grefe , D. Hynds , W. Klempt , I. Kremastiotis , J. Kröger , S. Kulis , E. Leogrande , L. Linssen , X. Llopart Cudie , A. Lucaci-Timoce , M. Munker , L. Musa , A. Nürnberg , F. -X. Nuiry , E. Perez Codina , H. Pernegger , M. Petrič , F. Pitters , T. Quast , S. Redford , P. Riedler , P. Roloff , A. Sailer , E. Santin , U. Schnoor , E. Sicking , K. Sielewicz , R. Simoniello , W. Snoeys , S. Spannagel , S. Sroka , R. Ström , P. Valerio , S. van Dam , E. van der Kraaij , T. Vǎnát , O. Viazlo , M. Vicente Barreto Pinto , M. A. Weber , M. Williams , K. Wolters , M. Benoit , G. Iacobucci , D M S Sultan , R. R. Bosley , T. Price , M. F. Watson , N. K. Watson , A. G. Winter , J. Goldstein , S. Green , J. S. Marshall , M. A. Thomson , B. Xu , G. Casse , J. Vossebeld , T. Coates , F. Salvatore , J. Repond , L. Xia , C. Kenney , A. Tomada

In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities…

Instrumentation and Detectors · Physics 2022-02-02 Manuel Christanell , Maximilian Tomaschek , Thomas Bergauer

We have investigated the depletion voltage changes, the leakage current increase and the charge collection efficiency of a silicon microstrip detector identical to those used in the inner layers of the BaBar Silicon Vertex Tracker (SVT)…

Instrumentation and Detectors · Physics 2009-11-10 S. Bettarini , M. Bondioli , L. Bosisio , G. Calderini , C. Campagnari , S. Dittongo , F. Forti , M. A. Giorgi , G. Marchiori , G. Rizzo

Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measurement of the tritium beta decay is the core of the TRISTAN…

Silicon strip sensors have long been a reliable technology for particle detection. Here, we push the limits of silicon tracking detectors by targeting an unprecedentedly low material budget of 2%-7% $X_0$ in an 8-layer 4 m$^2$ detector…