English
Related papers

Related papers: Capacitive coupling study of the HERD SCD prototyp…

200 papers

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays…

A 0.93 gram $1{\times}1{\times}0.4$ cm$^3$ SuperCDMS silicon HVeV detector operated at 30 mK was illuminated by 1.91 eV photons using a room temperature pulsed laser coupled to the cryostat via fiber optic. The detector's response under a…

The Compact Linear Collider (CLIC) is a concept for a future $e^{+}e^{-}$ linear collider with a center-of-mass energy of up to 3 TeV. The design of a CLIC experiment is driven by the requirements related to the physics goals, as well as by…

Instrumentation and Detectors · Physics 2014-02-13 Christian Grefe

Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…

A pixel detector with a CVD diamond sensor has been studied in a 180 GeV/c pion beam. The charge collection properties of the diamond sensor were studied as a function of the track position, which was measured with a silicon microstrip…

Instrumentation and Detectors · Physics 2009-11-10 T. Lari , A. Oh , N. Wermes , H. Kagan , M. Keil , W. Trischuk

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from…

Numerous applications at the photon-starved regime require a free-space coupling singlephoton detector with a large active area, low dark count rate (DCR), and superior time resolutions. Here,we developed a superconducting microstrip…

A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle…

Swept Charge Devices (SCD) are novel X-ray detectors optimized for improved spectral performance without any demand for active cooling. The Chandrayaan-1 X-ray Spectrometer (C1XS) experiment onboard the Chandrayaan-1 spacecraft used an…

Instrumentation and Methods for Astrophysics · Physics 2015-10-01 P. S. Athiray , P. Sreekumar , S. Narendranath , J. P. D. Gow

Silicon radiation detectors are an integral component of current and planned collider experiments in high energy physics. Simulations of these detectors are essential for deciding operational configurations, for performing precise data…

Instrumentation and Detectors · Physics 2023-01-02 B. Nachman , T. Peltola , P. Asenov , M. Bomben , R. Lipton , F. Moscatelli , E. A. Narayanan , F. R. Palomo , D. Passeri , S. Seidel , X. Shi , J. Sonneveld

The ion beam-induced charge (IBIC) analysis of a commercial silicon photodiode configured as a Position Sensitive Detector (PSD) for energetic charged particles is the subject of this report. Although the photodiode is designed for…

Instrumentation and Detectors · Physics 2024-12-17 Ettore Vittone , Georgios Provatas , Karla Ivanković Nizić , Milko Jaksic

We report recent results on the use of charge division to obtain a longitudinal coordinate from silicon strip detectors, and on sources of electronic readout noise for long, thin strips. These results hold promise for the design of Linear…

Instrumentation and Detectors · Physics 2010-05-18 Jerome Carman , Kelsey Collier , Sean Crosby , Vitaliy Fadeyev , Bruce A. Schumm , Ned Spencer

Superconducting Quantum Interference Devices (SQUIDs) can have excellent spin sensitivity depending on their magnetic flux noise, pick-up loop diameter, and distance from the sample. We report a family of scanning SQUID susceptometers with…

Existing Charge-Coupled Devices (CCDs) operate by detecting either the electrons or holes created in an ionization event. We propose a new type of imager, the Dual-Sided CCD, which collects and measures both charge carriers on opposite…

Sensing electric fields with high sensitivity, high spatial resolution and at radio frequencies can be challenging to realize. Recently, point defects in silicon carbide have shown their ability to measure local electric fields by optical…

Applied Physics · Physics 2019-09-04 Gary Wolfowicz , Christopher P. Anderson , Samuel J. Whiteley , David D. Awschalom

Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide band gap makes it an…

We are developing position sensitive silicon detectors (PSDs) which have an electrode at each of four corners so that incident position of a charged particle can be obtained with signal from the electrodes. It is expected that the position…

Instrumentation and Detectors · Physics 2020-05-28 Y. Uesugi , R. Mori , H. Yamashiro , T. Suehara , T. Yoshioka , K. Kawagoe

In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS…

Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation shifts, the samples were exposed to increasing fluences…

For the HERA upgrade, the ZEUS experiment has designed and installed a high precision Micro Vertex Detector (MVD) using single sided micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 microns, with…