English
Related papers

Related papers: First ClearMind gamma detector prototype for TOF-P…

200 papers

Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can be exploited to achieve an outstanding…

The selection of a suitable plasmonic material is extremely crucial for achieving high-performance photonic crystal fiber-based surface plasmon resonance (PCF-SPR) sensors. However, most numerical investigations to date are limited to…

Optics · Physics 2023-07-18 Tasmiah Tunazzina , Fairuz Areefin Khan , Anuva Chowdhury

We investigate the performance of large area radiation detectors, with high energy- and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development…

Instrumentation and Detectors · Physics 2018-04-18 P. Olleros , L. Caballero , C. Domingo-Pardo , V. Babiano , I. Ladarescu , D. Calvo , P. Gramage , E. Nacher , J. L. Tain , A. Tolosa

The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based…

Two measurements of the energy resolution were performed at MAX-Lab in Lund, Sweden, with an array of 3$\times$3 PbWO4 crystals using a tagged photon beam with energies between 19 and 56 MeV. The crystals were cooled down to -15 and -25…

Nuclear Experiment · Physics 2008-05-08 Sophie Grape

The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on…

A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…

Instrumentation and Detectors · Physics 2016-06-01 M. Bonesini , R. Bertoni , A. deBari , M. Rossella

Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging…

Instrumentation and Detectors · Physics 2024-12-25 Yuya Onishi , Ryosuke Ota

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude,…

Aim: Investigate whether a time walk assessment derived from crystal light sharing and multi-photon time stamps can improved the TOF resolution. Method: Monte Carlo simulations were performed for SiPM (FBK-NUV-HD) coupled to conventional…

Instrumentation and Detectors · Physics 2020-10-12 Stephan Walrand , Michel Hesse , François Jamar

PET is a functional imaging technique based on detection of annihilation photons following beta decay producing positrons. In this paper, we present the concept of a new PET system for preclinical applications consisting of a ring of twelve…

Instrumentation and Detectors · Physics 2015-03-19 A. Miceli , P. Amaudruz , F. Benard , D. A. Bryman , L. Kurchaninov , J. P. Martin , A. Muennich , F. Retiere , T. J. Ruth , V. Sossi , A. J. Stoessl

We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at…

High-resolution 3D tracking with sub-nanosecond timing is required for the detection of elementary particles, such as neutrinos. Conventional detectors, which utilize analog silicon photomultipliers, face challenges in balancing spatial…

Instrumentation and Detectors · Physics 2025-11-24 Kodai Kaneyasu , Till Dieminger , Matthew Franks , Davide Sgalaberna , Claudio Bruschini , Edoardo Charbon

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a…

The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping an optimal detector…

To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the…

Instrumentation and Detectors · Physics 2024-07-30 Yiding Zhao , D. Hu , M. Shao , Y. Zhou , S. Lv , Xiangqi Tian , Anqi Wang , Xueshen Lin , Hao Pang , Y. Suna

The TRIDENT (Tropical Deep-sea Neutrino Telescope) experiment is a next-generation underwater neutrino observatory planned for deployment in the West Pacific Ocean, designed to detect astrophysical neutrinos through Cherenkov radiation. The…

Instrumentation and Detectors · Physics 2025-11-20 Guangping Zhang , Yong Yang , Donglian Xu

We present a detailed study of an 8-channel $1\times1$ mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline.…

The TT-PET collaboration is developing an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of…