English
Related papers

Related papers: First ClearMind gamma detector prototype for TOF-P…

200 papers

In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of…

A PET scanner based on silicon photomultipliers (SiPMs) has been widely used as an advanced nuclear medicine imaging technique that yields quantitative images of regional in vivo biology and biochemistry. The compact size of the SiPM allows…

Instrumentation and Detectors · Physics 2022-02-02 Cong Ma , Xiaokun Zhao , Size Gao , Fengping Zhang , Guocheng Wu , Xing Li , Lei Lu , Hongwei Ye , Hua Qian

As a prototype detector for the SHiP Surrounding Background Tagger (SBT), we constructed a cell (120 cm x 80 cm x 25 cm) made from corten steel that is filled with liquid scintillator (LS) composed of linear alkylbenzene (LAB) and…

Since its inception, velocity map imaging (VMI) has been a powerful tool for measuring the 2D momentum distribution of photoelectrons generated by strong laser fields. There has been continued interest in expanding it into 3D measurements…

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for…

This work summarizes the design, construction, initial performance evaluation and pilot clinical results of the IMAS system, a long axial field of view (FOV), also known as total-body (TB-), positron emission tomography (PET) prototype…

In this paper, we provide a precise mathematical model of crystal-to-crystal response which is used to generate the white image - a necessary compensation model needed to overcome the physical limitations of the PET scanner. We present a…

Signal Processing · Electrical Eng. & Systems 2026-02-18 Tomislav Matulić , Damir Seršić

Presice measurements of the photons conversion points in the scintillators are required to achieve a high spatial resolution of the PET system. I have developed a new method of reconstruction of the depth-of-interaction information for PET…

Instrumentation and Detectors · Physics 2018-05-18 Andrei Yu. Semenov

We present first results from a Positron Emission Tomography (PET) scanner demonstrator based on Resistive Plate Chambers and specialized for brain imaging. The device features a 30 cm wide cubic field-of-view and each detector comprises 40…

The pyramid wavefront sensor (P-WFS) has replaced the Shack-Hartmann (SH-) WFS as sensor of choice for high performance adaptive optics (AO) systems in astronomy because of its flexibility in pupil sampling, its dynamic range, and its…

Recently we have proposed a new concept of a thermal neutron detector based on resistive plate chambers and 10B4C solid neutron converters, enabling to readout with high resolution in both the 3D position of neutron capture and the neutron…

Total Body PET (TBPET) scanners have recently demonstrated the ability to significantly reduce both acquisition time and the administered radioactive dose, thanks to their increased sensitivity. However, their widespread adoption is limited…

Instrumentation and Detectors · Physics 2025-06-25 S. R. Soleti , A. Castillo , J. I. Collar , M. del Barrio-Torregrosa , C. Echeverria , M. Seemann , D. Zerzion , J. J. Gómez Cadenas

The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process $e^+e^-\rightarrow \gamma A'$, where the $A'$ escapes detection. The dark photon…

The low cost and high resolution gas-based Multi-gap Resistive Plate Chamber (MRPC) opens a new possibility to find an efficient alternative detector for Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2011-06-30 A. Banerjee , S. Chattopadhyay

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…

Instrumentation and Detectors · Physics 2017-09-20 B. B. Wiggins , Varinderjit Singh , J. Vadas , J. Huston , T. K. Steinbach , S. Hudan , R. T. deSouza

Transparent objects are widely used in industrial automation and daily life. However, robust visual recognition and perception of transparent objects have always been a major challenge. Currently, most commercial-grade depth cameras are…

Computer Vision and Pattern Recognition · Computer Science 2022-09-20 Kang Chen , Shaochen Wang , Beihao Xia , Dongxu Li , Zhen Kan , Bin Li

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

This study demonstrates the feasibility of a novel fabrication technique for high spatial resolution CsI: Tl scintillation detectors tailored for single photon emission computed tomography (SPECT) systems. Building upon our previously…

Medical Physics · Physics 2026-02-16 Xi Zhang , Arkadiusz Sitek , Lisa Blackberg , Matthew Kupinski , Lars Furenlid , Hamid Sabet

We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…

Instrumentation and Detectors · Physics 2018-05-30 Sylvain Lupone , Pierre Soulisse , Philippe Roncin
‹ Prev 1 4 5 6 7 8 10 Next ›