The MIDNA application specific integrated circuits (ASICs) are a series of skipper-CCD readout chips fabricated in a 65 nm low-power CMOS process that implement a correlated double sampling signal processing chain based on dual-slope…

We describe a Cs atomic magnetometer operating in the spin-exchange relaxation-free (SERF) regime. With a vapor cell temperature of $103^\circ\rm{C}$ we achieve intrinsic magnetic resonance widths $\Delta B=17 {\rm \mu G}$ corresponding to…

Atomic Physics · Physics 2010-03-30 M. P. Ledbetter , I. M. Savukov , V. M. Acosta , D. Budker , M. V. Romalis

We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'',…

Full size single-sided GaAs microstrip detectors with integrated coupling capacitors and bias resistors have been fabricated on 3'' substrate wafers. PECVD deposited SiO_2 and SiO_2/Si_3N_4 layers were used to provide coupling capacitaces…

Instrumentation and Detectors · Physics 2009-10-30 R. Irsigler , R. Geppert , R. Goeppert , M. Hornung , J. Ludwig , M. Rogalla , K. Runge , Th. Schmid , A. Soldner-Rembold , M. Webel , C. Weber

We present a micro-mechanical terahertz (THz) detector fabricated on a silicon on insulator (SOI) substrate and operating at room-temperature. The device is based on a U-shaped cantilever of micrometric size, on top of which two aluminum…

We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to…

Astrophysics · Physics 2009-11-07 P. F. Bloser , F. Schopper , R. Andritschke , G. Kanbach , A. Zoglauer , P. Lechner

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector concept, one of the two detector concepts for the future International Linear Collider.…

Instrumentation and Detectors · Physics 2021-09-03 Fabricio Jimenez Morales

In this paper we present a simple and efficient built-in temperature sensor for thermal monitoring of standard-cell based VLSI circuits. The proposed smart temperature sensor uses a ring-oscillator composed of complex gates instead of…

Hardware Architecture · Computer Science 2011-11-09 S. A. Bota , M. Rosales , J. L. Rossello , J. Segura

Transition-edge sensor (TES) is a highly sensitive device that is capable of detecting extremely low levels of energy. It is characterised by low noise performance and high energy resolution. A mature method for reading out TES signal is…

Instrumentation and Detectors · Physics 2025-02-11 N. Li , X. Ren , H. Gao , Z. Zhang , Y. Zhang , C. Liu , H. Li , Z. Li

We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector…

The detection efficiency and response function of a Si(Li) detector element for the SIXA spectrometer have been determined in the 500 eV to 5 keV energy range using synchrotron radiation emitted at a bending magnet of the electron storage…

Instrumentation and Detectors · Physics 2009-10-30 T. Tikkanen , S. Kraft , F. Scholze , R. Thornagel , G. Ulm

The Simons Observatory (SO) is a cosmic microwave background experiment with over 67,000 polarization-sensitive transition-edge sensor (TES) detectors currently installed for use in observations and plans to increase the total detector…

This paper presents a Gm-C dynamic amplifier with high linearity and high temperature and power supply voltage stability. The main part of the amplifier employs two asymmetric differential pairs to enhance transconductance linearity. The…

Signal Processing · Electrical Eng. & Systems 2025-08-21 Jinkun Yang , Pengbin Xu

This paper presents the design, simulation, and analytical modeling of the single proposed axis MEMSbased capacitive accelerometer. Analytical modeling has been done for frequency and displacement sensitivity. The performance of the…

Systems and Control · Electrical Eng. & Systems 2021-11-09 Veena. S , Newton Rai , H. L. Suresh , Veda Sandeep Nagaraja

Subthreshold circuit designs are very much popular for some of the ultra low power applications, where the minimum energy consumption is the primary concern. But, due to the weak driving current, these circuits generally suffer from huge…

Hardware Architecture · Computer Science 2014-10-07 Dipankar Saha , Aanan Chatterjee , Sayan Chatterjee , C. K. Sarkar

Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement,…

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of…

A prototype of a Si-W EM calorimeter was built with Monolithic Active Pixel Sensors as the active elements. With a pixelsize of 30 $\mu$m it allows digital calorimetry, i.e. the particles' energy is determined by counting pixels, not by…

Instrumentation and Detectors · Physics 2018-02-14 A. P. de Haas , G. Nooren , T. Peitzmann , M. Reicher , E. Rocco , D. Roehrich , K. Ullaland , A. van den Brink , M. van Leeuwen , H. Wang , S. Yang , C. Zhang

We are developing an imaging polarimeter by combining a fine-pixel CMOS image sensor with a coded aperture mask as part of the cipher project, aiming to achieve X-ray polarimetry in the energy range of…