Related papers: Performance evaluation of GAGG(Ce)/LFS scintillato…
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…
Monte Carlo simulation plays an important role in the study of time of flight (TOF) positron emission tomography (PET) prototype. As it can incorporate accurate physical modeling of scintillation detection process, from scintillation light…
The first domestic inorganic scintillator CLYC was grown in Beijing Glass Research Instituteusing the vertical Bridgman method. In this work, we evaluated the performance of this new CLYC crystal in terms of gamma-ray energy resolution and…
This paper presents a world-leading scintillation light yield among inorganic crystals measured from a 0.5~kg pure-CsI detector operated at 77 Kelvin. Scintillation photons were detected by two 2-inch Hamamatsu SiPM arrays equipped with…
At present, a two-phase argon detector is being developed in our laboratory for dark matter search and low-energy neutrino experiments. To calibrate its energy scale a $^{109}$Cd gamma-ray source was used. In this work a detailed emission…
A gaseous time-projection chamber (TPC) with a reconstructable $z$ coordinate for nuclear recoil tracks has been developed for dark-matter searches and $\alpha$ particle imagings in a low radioactivity background. A TPC with a…
The Large High Altitude Air Shower Observatory (LHAASO) is designed for high energy gamma ray and cosmic ray detection. A Water Cherenkov Detector Array which is sensitive to gamma ray showers above a few hundred GeV is proposed to survey…
We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time…
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $\mu$m. Three analog pixels were…
We report demonstration of light detection in liquid argon using an acrylic lightguide detector system. This opens the opportunity for development of an inexpensive, large-area light collection system for large liquid argon time projection…
In this manuscript we report on the scintillation properties and pulse shape discrimination (PSD) performance of new organic glass scintillator. Two cylindrical samples with dimensions of 2x2 inches were tested. Additionally, this two…
Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in…
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these…
Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft \gamma-ray (10-600 keV) and medium-energy \gamma-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium…
In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…
The CALICE Analogue Hadron CALorimeter (AHCAL) at the International Linear Collider (ILC) is a high-granularity hadron calorimeter based on scintillator tiles readout by MPPCs. Toward the construction of ILC, the optimization of the AHCAL…
The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode…