Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator…
Theoretical background and data on the ways of practical realization are presented, related to the problem of detection of dangerous organic objects (explosives, drugs, etc.) in the presence of other organic substances with atomic number…
The performance of a silicon photomultiplier has been assessed at low temperature in order to evaluate its suitability as a scintillation readout device in liquid argon particle physics detectors. The gain, measured as 2.1E6 for a constant…
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…
The uncertainty of the energy measurement of the electron beam on circular electron positron collider (CEPC) must be smaller than 10$\mathrm{MeV}$ to make sure the accurate measurement of the mass of the Higgs boson. In order to simplify…
A new particle with mass ~ 125 GeV that resembles the Higgs boson has recently been discovered by ATLAS and CMS. We propose a low-energy gamma-gamma collider as a cost- and time-efficient option for a Higgs factory capable of studying this…
The interest in using the radiation detectors based on high resistive chromium-compensated GaAs (GaAs:Cr) in high energy physics and others applied fields has been growing steadily due to its numerous advantages over others classical…
A cryogenic detector system based on two 3.3 kg high-purity CsI crystals was developed and characterized at approximately 95 K. Each wedge-shaped crystal was coupled to dual-ended 3-inch photomultiplier tubes (PMTs) for scintillation…
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent…
Visibility scintillation resulting from wave propagation through the turbulent ionosphere can be an important sources of noise at low radio frequencies ($\nu\lesssim 200$ MHz). Many low frequency experiments are underway to detect the power…
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up…
The full instrument response of a superminiaturised CsI(Tl)-PiN photodiode radioactivity detector, intended for deployment on a meteorological radiosonde, has been modelled by combining a physics-based model of the sensor with the detector…
We discuss the results of a proton irradiation campaign of a GAGG:Ce (Cerium-doped Gadolinium Aluminium Gallium Garnet) scintillation crystal, carried out in the framework of the HERMES-TP/SP (High Energy Rapid Modular Ensemble of…
The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…
Measurements have been performed of scintillation light intensities emitted from various inorganic scintillators irradiated with low-energy beams of highly-charged ions from an electron beam ion source (EBIS) and an electron cyclotron…
We present a detailed characterization of the thermal neutron sensitive transparent glass scintillator SG101, benchmarked against the conventional LiF ZnS(Ag)based scintillator EJ426. The detection efficiency, energy resolution, and pulse…
Scintillator-based calorimeters for experiments at Higgs factories (e.g. ILC) demand scintillator designs that can detect sufficient number of photons and have good light yield uniformity, and that they can be easily mass-produced. In order…
A large area plastic scintillator detector array(~ 1 m x1m) has been set up for fast neutron spectroscopy at the BARC-TIFR Pelletron laboratory, Mumbai. The energy, time and position response has been measured for electrons using…
Plastic scintillator detectors have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. On the other hand, several articles have reported undesired response dependencies on beam…
The ALICE experiment is equipped with electromagnetic calorimeters of two different types: PHOS, the lead-tungstate photon spectrometer, and EMCAL, the sampling lead-scintillator calorimeter. These two detectors measure photon spectra in a…