Related papers: High resolution MCP-PMT Readout Using Transmission…
PET is a functional imaging technique based on detection of annihilation photons following beta decay producing positrons. In this paper, we present the concept of a new PET system for preclinical applications consisting of a ring of twelve…
Multichip modules (MCM) with 4 single photon counting MPEC 2.3 chips bump bonded to 1.3 cm x 1.3 cm large CdTe and Si semiconductor sensors as well as to single chip pixel detectors have been successfully built and operated. The MPEC 2.3…
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…
A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs…
PETALO (a Positron Emission Tof Apparatus based on Liquid xenOn) is a new approach for Positron Emission Tomography scanners, based on liquid xenon. The PETALO detector aims at capturing the light produced by the scintillation in LXe taking…
We present the first detailed study of an 8-channel $2\times2$ mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV proton beam and 8 GeV electron and pion beam at the Fermilab Test Beam Facility.…
Silicon photomultipliers are increasingly replacing photomultiplier tubes in Cherenkov telescope cameras, but achieving single-photoelectron resolution with nanosecond timing in a low-noise, scalable detector system remains challenging. We…
Experimental measurements of the radial spreading of photoelectrons emitted from a multi-alkali photocathode in a MCP-based photomultiplier tube have shown that, for photon wavelengths of 455 nm, 515 nm and 625 nm, the maximum initial…
In order to further enhance the particle identification capability of the Beijing Spectrometer (BESIII), it is proposed to upgrade the current end-cap time-of-flight (eTOF) detector with multi-gap resistive plate chamber (MRPC). The…
A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…
Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible-light and other…
Photomultiplier tubes (PMTs) with large-area cathodes are increasingly being used in cosmic-ray experiments to enhance detection efficiency. The optical modules (OMs) of the High-Energy Underwater Neutrino Telescope (HUNT) have employed a…
We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each…
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…
We report on the detection of single photons with {\lambda} = 8 {\mu}m using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 {\mu}m^3 fabricated on a silicon…
Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to…
The superconducting nanowire single photon detector (SNSPD) is a leading technology for quantum information science applications using photons, and they are finding increasing uses in photon-starved classical imaging applications. Critical…
We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing…
This work presents a comprehensive characterization of the FERS 5202 front-end readout unit when processing signals from Silicon Photo-multipliers (SiPMs). The readout system's performance is characterized in terms of its charge resolution,…
We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete…