English
Related papers

Related papers: High resolution MCP-PMT Readout Using Transmission…

200 papers

This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterra\'aneo de Canfranc (LSC) in Huesca, Spain.…

Instrumentation and Detectors · Physics 2018-12-26 V. Álvarez , V. Herrero , R. Esteve , A. Laing , J. Rodríguez , M. Querol , F. Monrabal , J. F. Toledo , J. J. Gómez-Cadenas

Microchannel plates (MCPs) were recently proposed as novel type of cathodes for electron guns, suitable for applications in design of electron lenses. We report results of the first systematic study of microchannel plate based…

Accelerator Physics · Physics 2018-07-12 M. Haughey , V. Shiltsev , G. Stancari

The central institute of electronics (ZEA-2) in the Forschungszentrum Juelich (FZJ) has developed a system to scan the response of the photocathode of photomultiplier tubes (PMT). The PMT sits tight on a supporting structure, while a blue…

Instrumentation and Detectors · Physics 2013-07-05 R. Fabbri

Recent studies of positron emission tomography (PET) devices have shown that the detection of polarization-correlated annihilation quanta can potentially reduce the background and creation of false lines of response (LORs) leading to…

The demand for a large number of readout channels has been a limiting factor for the application of Micro-pattern Gaseous Detectors (MPGDs) in achieving higher spatial resolution and larger detection areas. This challenge is further…

Instrumentation and Detectors · Physics 2025-05-22 Yu Wang , Shubin Liu , Hao Zhuang , Zhengwu Ding , Zhihang Yao , Changqing Feng , Zhiyong Zhang

The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$)…

Since the early days of experimental particle physics photomultipliers (PMTs) have played an important role in the detector design. Thanks to their capability of fast photon counting, PMTs are extensively used in the new-generation of…

Instrumentation and Detectors · Physics 2016-08-24 C. Bozza , T. Chiarusi , M. Costa , F. Di Capua , V. Kulikovskiy , R. Mele , P. Migliozzi , C. M. Mollo , C. Pellegrino , G. Riccobene , D. Vivolo

The atomic layer deposition(ALD) coating lengthens the lifetime of microchannel plates(MCP), which are used as the electron amplifier of the photomultiplier tubes(PMT). In the Jinping Neutrino Experiment, the newly developed 8-inch MCP-PMT…

Instrumentation and Detectors · Physics 2024-07-31 Jun Weng , Aiqiang Zhang , Qi Wu , Lishuang Ma , Benda Xu , Sen Qian , Zhe Wang , Shaomin Chen

Scanning transmission electron microscopy is a common tool used to study the atomic structure of materials. It is an inherently multimodal tool allowing for the simultaneous acquisition of multiple information channels. Despite its…

Results obtained with 3D columnar pixel sensors bump-bonded to the RD53A prototype readout chip are reported. The interconnected modules have been tested in a hadron beam before and after irradiation to a fluence of about…

Development of readout electronics for Time Projection Chamber for a Linear Collider is ongoing under stringent requirements on high channel density, lowest possible power consumption and small material budget. In the studied TPC readout…

Instrumentation and Detectors · Physics 2009-02-02 Alexander Kaukher

The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD)…

Instrumentation and Detectors · Physics 2022-04-26 M. Dixit , D. Attie , A. Bellerive , K. Boudjemline , P. Colas , P. Giganon , I. Giomataris , V. Lepeltier , S. Liu , J. -P. Martin , K. Sachs , Y. Shin , S. Turnbull

A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…

Silicon photomultipliers (SiPMs) are being considered as potential replacements for conventional photomultiplier tubes (PMTs). However, a significant disadvantage of SiPMs is crosstalk (CT), wherein photons propagate through other pixels,…

Instrumentation and Detectors · Physics 2024-06-05 Guanda Li , Lei Wang , Xilei Sun , Fang Liu , Cong Guo , Kangkang Zhao , Lei Tian , Zeyuan Yu , Zhilong Hou , Chi Li , Yu Lei , Bin Wang , Rongbin Zhou

The Institute for Astronomy and Astrophysics in T\"ubingen (IAAT) has a long-term experience in developing and building space-qualified imaging and photon counting microchannel-plate (MCP) detectors, which are sensitive in the ultraviolet…

The EndoTOFPET-US project aims to jointly exploit Time-Of-Flight Positron Emission Tomography (TOFPET) and ultrasound endoscopy with a multi-modal instrument for the development of new biomarkers for pancreas and prostate oncology. The…

Instrumentation and Detectors · Physics 2013-03-20 Erika Garutti

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a…

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted…

The integrated optical circuit is a promising architecture for the realization of complex quantum optical states and information networks. One element that is required for many of these applications is a high-efficiency photon detector…

A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…

Instrumentation and Detectors · Physics 2024-07-16 João Pedro de Carvalho Saraiva , Alberto Blanco Castro
‹ Prev 1 8 9 10 Next ›