English

Test of High Time Resolution MRPC with Different Readout Modes

Instrumentation and Detectors 2014-12-16 v1 High Energy Physics - Experiment

Abstract

In order to further enhance the particle identification capability of the Beijing Spectrometer (BESIII), it is proposed to upgrade the current end-cap time-of-flight (eTOF) detector with multi-gap resistive plate chamber (MRPC). The prototypes, together with the front end electronics (FEE) and time digitizer (TDIG) module have been tested at the E3 line of Beijing Electron Positron Collider (BEPCII) to study the difference between the single and double-end readout MRPC designs. The time resolutions (sigma) of the single-end readout MRPC are 47/53 ps obtained by 600 MeV/c proton/pion beam, while that of the double-end readout MRPC is 40 ps (proton beam). The efficiencies of three MRPC modules tested by both proton and pion beam are better than 98%. For the double-end readout MRPC, no incident position dependence is observed.

Keywords

Cite

@article{arxiv.1405.2115,
  title  = {Test of High Time Resolution MRPC with Different Readout Modes},
  author = {S. Yang and Y. J. Sun and C. Li and Y. K. Heng and S. Qian and H. F. Chen and T. X. Chen and H. L. Dai and H. H. Fan and S. B. Liu and S. D. Liu and X. S. Jiang and M. Shao and Z. B. Tang and H. Zhang and Z. G. Zhao},
  journal= {arXiv preprint arXiv:1405.2115},
  year   = {2014}
}

Comments

16 pages, 16 figures, Submitted to Nucl. Instr. and Meth. A

R2 v1 2026-06-22T04:09:45.763Z