English
Related papers

Related papers: Dosimetric Comparison of Passive Scattering and Ac…

200 papers

Objective: To develop and validate an independent Monet Carlo dose calculation engine to support for software verification of treatment planning systems and quality assurance workflow. Method: GATE Monte Carlo toolkit was employed to…

Medical Physics · Physics 2021-07-27 A. Asadi , A. Akhavanallaf , S. A. Hosseini , N. vosoughi , H. Zaidi

The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power…

Background and purpose: In-beam Positron Emission Tomography (PET) is one of the modalities that can be used for in-vivo non-invasive treatment monitoring in proton therapy. PET distributions obtained during various treatment sessions can…

Objective: To assess the accuracy and computational performance of a stochastic differential equation (SDE)--based model for proton beam dose calculation by benchmarking against Geant4 in simplified phantom geometries. Approach: Building on…

Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stopping power (RSP) within the patient is vital. Conversion errors…

A novel dose calculation approach was designed based on the application of LSTM network that processes the 3D patient/phantom geometry as a sequence of 2D computed tomography input slices yielding a corresponding sequence of 2D slices that…

Medical Physics · Physics 2021-06-09 Ahmad Neishabouri , Niklas Wahl , Ulrich Köthe , Mark Bangert

When treating moving tumors, the precise delivery of proton therapy by pencil beam scanning (PBS) is challenged by the interplay effect. Although several 4D-optimization methods have been proposed, what is the most beneficial motion…

Medical Physics · Physics 2025-01-29 Ivar Bengtsson , Anders Forsgren , Albin Fredriksson

PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements…

For the in vivo range verification in proton therapy, it has been tried to measure the spatial distribution of the prompt gammas generated by the proton-induced interactions with the close relationship with the proton dose distribution.…

Medical Physics · Physics 2015-03-13 Wook-Geun Shin , Chul Hee Min , Jae-Ik Shin , Jong Hwi Jeong , Se Byeong Lee

Background and Objective: Recent experimental studies using ultra-high dose rate radiation therapy (FLASH-RT) have shown improved normal tissue sparing and comparable tumor control compared to conventional dose rate RT. Pencil beam scanning…

We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of…

Purpose: To enhance an in-house graphic-processing-unit (GPU) accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning…

Proton therapy's full potential is limited by uncertainties that prevent optimal dose distribution. Monitoring techniques can reduce these uncertainties and enable adaptive treatment planning. Spatiotemporal Emission Reconstruction from…

Purpose: Prior AI-based dose prediction studies in photon and proton therapy often neglect underlying physics, limiting their generalizability to handle outlier clinical cases, especially for pencil beam scanning proton therapy (PBSPT). Our…

This paper focuses on some dosimetry aspects of proton therapy and pencil beam scanning based on the experience accumulated at Paul Scherrer Institute(PSI). The basic formalism for absolute dosimetry in proton therapy is outlined and the…

Medical Physics · Physics 2018-04-24 S. Safai

Purpose: To develop a DL-based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on-line adaptive proton therapy clinical decision and subsequent replanning. Methods: PBSPT plans of 103 prostate cancer…

Proton beam therapy has been developed to irradiate the tumor with higher precision and dose conformity compared to conventional X-ray irradiation. The dose conformity of this treatment modality may be further improved if narrower proton…

Proton therapy systems without a gantry can be more compact and less expensive in terms of capital cost, and therefore more available to a larger patient population. Would the advances in pencil beam scanning and robotics make gantry-less…

Purpose: The purpose of this work was to provide a flexible platform for FLASH research with protons by adapting a former clinical pencil beam scanning gantry to irradiations with ultrahigh dose rates. Methods: PSI Gantry 1 treated patients…

Proton scattering in some water and tissue equivalent phantom materials was measured to evaluate their simulation accuracy of water and respective human biological tissues. The measurements were performed on the medical facility of the ITEP…

Medical Physics · Physics 2010-11-23 V. N. Vasiliev , V. I. Kostjuchenko , V. G. Khaybullin , S. I. Samarin , A. S. Uglov
‹ Prev 1 2 3 10 Next ›