Related papers: Dosimetric Comparison of Passive Scattering and Ac…
The XCAT phantom is a realistic 4D digital torso phantom that is widely used in imaging and therapy research. However, lung mass is not conserved between respiratory phases of the phantom, making detailed dosimetric simulations and dose…
Background: FLASH radiation therapy (FLASH-RT) uses ultra-high dose rates to induce the FLASH effect, enhancing normal tissue sparing. In proton Bragg peak FLASH-RT, this effect is confined to high-dose regions near the target at deep…
Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better…
Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy…
The Alpha Magnetic Spectrometer (AMS) is a high-precision particle detector onboard the International Space Station containing six different subdetectors. The Transition Radiation Detector and Electromagnetic Calorimeter (ECAL) are used to…
Spatial scheduling of electrode activation ("rastering") is essential for safely operating high-density retinal implants, yet its perceptual consequences remain poorly understood. This study systematically evaluates the impact of raster…
Purpose: To improve target coverage and reduce the dose in the surrounding organs-at-risks (OARs), we developed an image-guided treatment method based on a precomputed library of treatment plans controlled and delivered in real-time.…
Measuring disease progression in clinical trials for testing novel treatments for multifaceted diseases as Progressive Supranuclear Palsy (PSP), remains challenging. In this study we assess a range of statistical approaches to compare…
Purpose: Pencil beam scanning proton therapy is sensitive to respiratory motion, leading to potential dose inhomogeneities due to interplay effects. We developed and validated a predictive framework to assess interplay and motion robustness…
In particle therapy, knowledge of the stopping-power ratios (STPRs) of the ion beam for air and water is necessary for accurate ionization chamber dosimetry. Earlier work has investigated the STPRs for pristine carbon ion beams, but here we…
The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the…
Single minibeams of protons, $^{4}$He, $^{12}$C and $^{16}$O in water were modeled with Geant4, and their dose distributions were parameterized with double-Gauss-Rutherford (DGR) functions. Dose distributions from arrays of 16 parallel…
Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT…
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue…
Monte Carlo (MC) simulations provide gold-standard accuracy for carbon ion therapy dose calculations but are computationally intensive. Analytical pencil beam algorithms offer speed but reduced accuracy in heterogeneous tissues. We…
In this study, cone-beam single projection and axial CT scans are modeled with a software package - DOCTORS, which solves the linear Boltzmann equation using the discrete ordinates method. Phantoms include a uniform 35 cm diameter water…
Introduction: Terbium-149 ($^{149}$Tb) is a promising radionuclide for targeted $\alpha$ therapy that has a non-zero branching ratio (BR) for positron decay. However, its relatively low positron branching fraction and multiple prompt…
The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to…
Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to…
Positron Emission Tomography (PET) is a Nuclear Medicine technique that creates images that allow the study of metabolic activity and organ function using radiopharmaceuticals. Continuous improvement of scintillation detectors for radiation…