Related papers: Dosimetric Comparison of Passive Scattering and Ac…
In this study, the absorbed dose calculation for the cerebral region is refined using the Geant4 software, along with the ROOT and GATE programs. This approach provides a detailed statistical analysis of positron trajectories within a water…
Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly…
Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of range shifting and compensating materials. In dosimetry, solid…
In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner.…
Stereotactic body radiation therapy (SBRT) and hypofractionation using pencil-beam scanning (PBS) proton therapy (PBSPT) is an attractive option for thoracic malignancies. Combining the advantages of target coverage conformity and critical…
To improve the quality of cancer treatment with protons, a translation of X-ray Computed Tomography (CT) images into a map of the proton stopping powers needs to be more accurate. Proton stopping powers determined from CT images have…
Positronium-based imaging requires realistic modelling of positronium (Ps) decay in matter. We introduce a modular Ps decay model implemented in GATE 9.4 and GATE 10, enabling the definition of an arbitrary number of decay channels…
Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT 4…
Purpose: VT is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. STAR has emerged as a non-invasive option for such patients. While photon-based STAR has…
Purpose: Highlight the distinctions, both in terms of concept and numerical values, of the various definitions that can be established for the dose rate in PBS proton therapy. Methods: In an in silico study, five definitions of the dose…
Pencil beam scanning (PBS) proton therapy provides highly conformal dose distributions that are increasingly leveraged for postmastectomy radiation therapy (PMRT) to reduce cardiopulmonary exposure. However, implant-based reconstruction in…
Purpose: To verify dose delivery and quality assurance of volumetric modulated arc therapy (VMAT) for head and neck cancer. Method: The Imaging and Radiation Oncology Core Houston (IROC-H) head and neck phantom with thermo- luminescent…
Arrays of minibeams of protons and $^{12}$C in tissue-like media were modeled with Geant4 toolkit. A set of beam energies was used in simulations to provide a Spead-out Bragg peak (SOBP) extended by 6 cm in depth for protons as well as for…
Proton beam therapy can potentially offer improved treatment for cancers of the head and neck and in paediatric patients. There has been a sharp uptake of proton beam therapy in recent years as improved delivery techniques and patient…
Intensity-modulated proton therapy (IMPT) employs proton radiation rather than conventional X-rays to treat cancerous tumors. This approach offers significant advantages by minimizing the radiation exposure of surrounding healthy tissue,…
Accurate 3D dose calculation for Pencil Beam Scanning Proton Therapy (PBSPT) is typically performed with Monte Carlo (MC) engines, but their runtimes limit adaptive workflows and repeated evaluations. Current deep-learning proton dose…
Particle physics simulations are the cornerstone of nuclear engineering applications. Among them radiotherapy (RT) is crucial for society, with 50% of cancer patients receiving radiation treatments. For the most precise targeting of tumors,…
Purpose: This study explores the feasibility of dose-escalated proton beam therapy (dPBT) for Locally Advanced Pancreatic Cancer (LAPC) patients by modeling common patient scenarios using current clinically-adopted practices. Methods: Five…
Purpose: The FLASH effect, which reduces the radiosensitivity of healthy tissue while maintaining tumor control at high dose rates, has shown potential for improving radiation therapy. Conformal FLASH proton therapy involves advanced…
Two full rotating gantry with different nozzles (Multipurpose nozzle with MLC, Scanning Dedicated nozzle) with conventional cyclotron system is installed and under commissioning for various proton treatment options at Samsung Medical Center…