Related papers: Improving spatial resolution in X-ray microscopy b…
Context. Narrow-band interference filters can be tuned toward shorter wavelengths by tilting them from the perpendicular to the optical axis. This can be used as a cheap alternative to real tunable filters, such as Fabry-P\'erot…
Improving angular resolution is one of X-ray astronomy's big challenges. While X-ray interferometry should eventually vastly improve broad-band angular resolution, in the near-term, X-ray telescopes will sacrifice angular resolution for…
To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital…
One of the challenges of X-ray astronomy is how to both collect large numbers of photons yet attain high angular resolution. Because X-ray telescopes utilize grazing optics, to collect more photons requires a larger acceptance angle which…
In this work, we measure and model tilted x-ray refractive lenses to investigate their effects on an x-ray beam. The modelling is benchmarked against at-wavelength metrology obtained with x-ray speckle vector tracking experiments (XSVT) at…
X-ray imaging is the most widely used medical imaging modality. However, in the common practice, inconsistency in the initial presentation of X-ray images is a common complaint by radiologists. Different patient positions, patient habitus…
High-resolution spectroscopy in soft X-rays ($<2$ keV) requires diffractive elements to resolve any astrophysically relevant diagnostics, such as closely spaced lines, weak absorption lines, or line profiles. The Rowland torus geometry…
Complementary metal-oxide-semiconductor (CMOS) sensors are a competitive choice for future X-ray astronomy missions. Typically, CMOS sensors on space astronomical telescopes are exposed to a high dose of irradiation. We investigate the…
As photon counting detectors are being explored for medical and industrial imaging applications, there is a critical need to understand spectral characteristics of scattered x-ray photons. Scattered radiation is detrimental to x-ray imaging…
When an X-ray area detector based on a single crystalline material, for instance, a state of the art hybrid pixel detector, is illuminated from a point source by monochromatic radiation, a pattern of lines appears which overlays the…
A charge-coupled device (CCD) is a standard imager in optical region in which the image quality is limited by its pixel size. CCDs also function in X-ray region but with substantial differences in performance. An optical photon generates…
This paper discusses the broad science case for obtaining milliarcsecond to microarcsecond astronomical imaging resolution in the soft to medium-energy X-ray band (~0.5 to ~8 keV). Astronomy across much of the electromagnetic spectrum has…
X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and opaque instruments. In most commercial x-ray modalities, an image is formed by measuring the x-rays that pass through the object of…
X-ray phase-contrast imaging has the potential to improve image contrast with lower dose by probing an object's refractive properties as well as its absorptive properties. To reconstruct a phase-contrast image from a raw dataset, a phase…
Blur in X-ray radiographs not only reduces the sharpness of image edges but also reduces the overall contrast. The effective blur in a radiograph is the combined effect of blur from multiple sources such as the detector panel, X-ray source…
X-ray ptychography utilizes overlapping illuminations to reconstruct the object's phase and absorption signal with spatial resolutions much smaller than the focus size. Usually, the illumination overlap is chosen to be between 50% and 60%…
Small-angle X-ray scattering (SAXS) technique enables convenient nanoscopic characterization for various systems and conditions. Nonetheless, lab-based SAXS systems intrinsically suffer from insufficient x-ray flux and limited angular…
We study conditions for aberration-free imaging of inelastic x-ray scattering (IXS) spectra with x-ray echo spectrometers. Aberration-free imaging is essential for achieving instrumental functions with high resolution and high contrast.…
Grazing incidence mirrors for X-ray astronomy are usually designed in the parabola-hyperbola (Wolter I) configuration. This design allows for optimal images on-axis, which however degrade rapidly with the off-axis angle. Mirror surfaces…
We present a concept of the X-ray imaging system with high angular-resolution and moderate sensitivity. In this concept, a two-dimensional detector, i.e., imager, is put at a slightly out-of-focused position of the focusing mirror, rather…