We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a…

High-resolution ($R = \lambda /\Delta \lambda > 2000$) x-ray absorption and emission line spectroscopy in the soft x-ray band is a crucial diagnostic for the exploration of the properties of ubiquitous warm and hot plasmas and their…

Transition-edge sensors (TESs) as microcalorimeters offer high resolving power, owning to their sharp response and low operating temperature. In the hard X-ray regime and above, the demand for high quantum-efficiency requires the use of…

Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will…

Transition-edge sensors (TESs) have the potential to perform electron spectroscopic measurements with far greater measurement rates and efficiencies than can be achieved using existing electron spectrometers. Existing spectrometers filter…

Instrumentation and Detectors · Physics 2024-03-05 K. M. Patel , S. Withington , A. G . Shard , D. J. Goldie , C. N. Thomas

If a hypothetical elementary particle called an axion exists, to solve the strong CP problem, a 57Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition. If such axions are once more transformed…

Instrumentation and Methods for Astrophysics · Physics 2023-04-20 Yuta Yagi , Tasuku Hayashi , Keita Tanaka , Rikuta Miyagawa , Ryo Ota , Noriko Y. Yamasaki , Kazuhisa Mitsuda , Nao Yoshida , Mikiko Saito , Takayuki Homma

A 1M- and a 4M-pixel monolithic CMOS active pixel sensor with 9.5x9.5 micron^2 pixels have been developed for direct imaging in transmission electron microscopy as part of the TEAM project. We present the design and a full characterisation…

We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…

Instrumentation and Detectors · Physics 2022-01-27 Ángela Saá Hernández , Diego González-Díaz , Pablo Villanueva , Carlos Azevedo , Marcos Seoane

We describe the design, fabrication, and validation of a cryogenically-compatible quasioptical thermal source designed to be used for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that…

Instrumentation and Methods for Astrophysics · Physics 2017-10-25 David T. Chuss , Karwan Rostem , Edward J. Wollack , Leah Berman , Felipe Colazo , Martin DeGeorge , Kyle Helson , Marco Sagliocca

Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature…

X-ray calorimetric sample platforms combining specific heat and synchrotron x-ray measurements provide a powerful means to investigate fundamental material properties. Calorimeter cell designs featuring a compact heater and thermometer…

Instrumentation and Detectors · Physics 2026-02-02 U. Patel , H. Zheng , J. L. McChesney , U. Welp , Z. Islam , A. Miceli

Transition Edge Sensors are ultra-sensitive superconducting detectors with applications in many areas of research, including astrophysics. The device consists of a superconducting thin film, often with additional normal metal features, held…

Instrumentation and Methods for Astrophysics · Physics 2018-05-18 R. C. Harwin , D. J. Goldie , S. Withington , P. Khosropanah , L. Gottardi , J. -R. Gao

We demonstrate the code-division multiplexed (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of…

Instrumentation and Detectors · Physics 2012-02-15 G. M. Stiehl , W. B. Doriese , J. W. Fowler , G. C. Hilton , K. D. Irwin , C. D. Reintsema , D. R. Schmidt , D. S. Swetz , J. N. Ullom , L. R. Vale.

At low temperatures, < 200 mK, the thermal flux through low-dimensional amorphous dielectric bars, < 2 $\mu$m wide and 200 nm thick, is transported by a small number of low-order elastic modes. For long bars, L > 400 $\mu$m, it is known…

Mesoscale and Nanoscale Physics · Physics 2017-09-13 Stafford Withington , Emily Williams , David J. Goldie , Christopher N. Thomas , Max Schneiderman

We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few…

The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of…

Instrumentation and Detectors · Physics 2021-09-03 Jiaxing Wen , Minghai Yu , Yuchi Wu , Ming Zeng , Bo Zhang , Jirong Cang , Yuge Zhang , Ge Ma , Yue Yang , Wenbo Mo , Zongqing Zhao

A method is presented which allows to obtain the position-dependent electric field and charge density by fits to velocity profiles from edge-TCT data from silicon strip-detectors. The validity and the limitations of the method are…

Instrumentation and Detectors · Physics 2020-01-08 R. Klanner , G. Kramberger , I. Mandic , M. Mikuz , M. Milovanovic , J. Schwandt

Coherent elastic neutrino-nucleus scattering (CE$\nu$NS) offers valuable sensitivity to physics beyond the Standard Model. The Ricochet experiment will use cryogenic solid-state detectors to perform a precision measurement of the CE$\nu$NS…

The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow…

The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out…