Related papers: Development of Transition-Edge Sensor X-ray Microc…
An array of compound refractive X-ray lenses (CRL) with 20x20 lenslets, a focal distance of 20 cm and a visibility of 0.93 is presented. It can be used as a Shack-Hartmann sensor for hard X-rays (SHARX) for wavefront sensing and permits for…
We propose a spintronic strain sensor capable of sensing strain with a sensitivity of 1E-13/sqrt{Hz} at room temperature with an active sensing area of 1 cmE2 and power dissipation of 1 watt. This device measures strain by monitoring the…
Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…
A cryo scanning transmission X-ray microscope, the cryo-STXM, has been designed and commissioned at the Canadian Light Source synchrotron. The instrument is designed to operate from 100 - 4000 eV (lambda = 12.4 - 0.31 nm). Users can insert…
We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle…
The 511 keV electron-positron annihilation feature near the galactic center has been detected for more than half a century, yet its origin remains a mystery. In this paper, we describe a concept for a balloon-borne 511 keV $\gamma$-ray…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
An ultrafast photoemission-based low-energy electron diffraction experiment with monolayer surface sensitivity is presented. In a first experiment on tin-phthalocyanine adsorbed on graphite, we demonstrate a time resolution of approx. 100…
Optical excitation and subsequent decay of graphene plasmons can produce a significant increase in charge-carrier temperature. An efficient method to convert this temperature elevation into a measurable electrical signal at room temperature…
We report on a flow velocity measurement technique based on snap-through detection of an electrostatically actuated, bistable micromechanical beam. We show that induced elecro-thermal Joule heating and the convective air cooling change the…
The European X-ray Free Electron Laser (XFEL) will deliver 27000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single molecules and the…
We characterised a TES-based X-ray microcalorimeter in an adiabatic demagnetisation refrigerator (ADR) using synchrotron radiation. The detector response and energy resolution was measured at the beam-line in the PTB radiometry laboratory…
Hybrid pixel single-photon-counting detectors have been successfully employed and widely used in Synchrotron radiation X-ray detection. In this paper, the silicon pixel sensors for single X-ray photon detection, which operate in…
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium…
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that…
When an X-ray area detector based on a single crystalline material, for instance, a state of the art hybrid pixel detector, is illuminated from a point source by monochromatic radiation, a pattern of lines appears which overlays the…
The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and…
The so-called excess noise limits the energy resolution of transition-edge sensor (TES) detectors, and its physical origin has been unclear, with many competing models proposed. Here we present the noise and impedance data analysis of a…
Time-dependent and constituent-specific spectral changes in soft near edge X-ray spectroscopy (XAS) of an [Fe/MgO]$_8$ metal/insulator heterostructure upon laser excitation are analyzed at the O K-edge with picosecond time resolution. The…
Photodetectors based on nano-structured superconducting thin films are currently some of the most sensitive quantum sensors and are key enabling technologies in such broad areas as quantum information, quantum computation and…