Related papers: Development of Transition-Edge Sensor X-ray Microc…
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…
We have developed a novel procedure for constructing high surface area silver sinter heat exchangers. Our recipe incorporates nylon fibers having a diameter of ~ 50 microns and thin wires of bulk silver in the heat exchanger. In order to…
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed,…
The paper presents a reflectionless stripline filter with reduced dimensions having a single bandwidth over a wide frequency range. The filter consists of coupled strip lines and RLC circuits included in the diagonal ports of the coupled…
Active edge p-on-p silicon pixel detectors with thickness of 100 $\mu$m were fabricated on 150 mm Float zone silicon wafers at VTT. By combining measured results and TCAD simulations, a detailed study of electric field distributions and…
We report the development of a continuous-wave and pulsed X-band electron spin resonance (ESR) spectrometer for the study of spins on ordered surfaces down to cryogenic temperatures. The spectrometer operates in ultra-high vacuum and…
Efficient thermal management is essential for the reliability of modern power electronics, where increasing device density leads to severe heat dissipation challenges. However, in thin-film systems, thermal transport is often compromised by…
The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020)…
We report on the simulation results for the angular resolution of an electromagnetic (EM) sampling calorimeter with photons in the range of 100~MeV to 2~GeV. The simulation model of the EM calorimeter consists of alternating layers of a…
The responsivity and noise of a voltage-biased superconducting transition-edge sensor depends strongly on the details of its thermal model, and the simplest theory for TES response assumes a single heat capacity connected to the heat bath.…
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting…
Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes through the silicon substrate of a TES array, a large amount…
We present a silicon drift detector (SDD) system for the spectroscopy focusing array (SFA) of the enhanced X-ray timing and polarimetry (eXTP) mission. The SFA focuses on fast timing (time resolution below 10 {\mu}s) and good spectroscopy…
We have designed and implemented an experiment to measure the angular distributions and the energy spectra of the transition radiation X-rays emitted by fast electrons and positrons crossing different radiators. Our experiment was selected…
2D profiles of electron density and neutral temperature are inferred from multi-delay Coherence Imaging Spectroscopy data of divertor plasmas using a non-linear inversion technique. The inference is based on imaging the spectral…
Transient X-ray absorption techniques can measure ultrafast dynamics of the elemental edges in a material or multiple layer junction, giving them immense potential for deconvoluting concurrent processes. However, the interpretation of the…
We have developed low-dispersion (1480 l/mm), resonance-free, diffraction gratings made of dielectric materials resistant to femtosecond laser damage $(SiO_{2}/HfO_{2})$. A 14 cm diameter sample was fabricated resulting in a mean…
A high sensitivity atom flux sensor based on atomic absorption spectroscopy has been designed and implemented to control electron beam evaporators and effusion cells in a molecular beam epitaxy system. Using a high-resolution spectrometer…
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT)…
A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…