English
Related papers

Related papers: Development of Transition-Edge Sensor X-ray Microc…

200 papers

Diffuse X-ray Explorer (DIXE) is a proposed X-ray spectroscopic survey experiment for the China Space Station. Its detector assembly (DA) contains the transition edge sensor (TES) microcalorimeter and readout electronics based on the…

Instrumentation and Methods for Astrophysics · Physics 2024-05-14 Jiejia Liu , Sifan Wang , Hai Jin , Qian Wang , Wei Cui

Using the multi-channel Transient Current Technique the currents induced by electron-hole pairs, produced by a focussed sub-nanosecond laser of 660 nm wavelength close to the Si-SiO2 interface of p+n silicon strip sensors have been…

Instrumentation and Detectors · Physics 2015-06-15 Thomas Poehlsen , Julian Becker , Eckhart Fretwurst , Robert Klanner , Jörn Schwandt , Jiaguo Zhang

The superconducting Transition-Edge Sensor (TES) is a critical technology for next-generation X-ray spectrometers, known for its exceptional energy resolution. In the last decade, TESs based on AlMn alloy films have been extensively used in…

Instrumentation and Methods for Astrophysics · Physics 2026-02-13 Liangpeng Xie , Yifei Zhang , Zhengwei Li , Zhouhui Liu , Shibo Shu , Junjie Zhou , Xufang Li , Haoyu Li , He Gao , Yudong Gu , Xuefeng Lu , Yong Zhao , Congzhan Liu

We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent…

Instrumentation and Detectors · Physics 2014-03-06 S. Okada , D. A. Bennett , W. B. Doriese , J. W. Fowler , K. D. Irwin , S. Ishimoto , M. Sato , D. R. Schmidt , D. S. Swetz , H. Tatsuno , J. N. Ullom , S. Yamada

Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…

Instrumentation and Detectors · Physics 2026-04-29 Jodok Zeuner , Constantin Schuster , Sebastian Kempf

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X- ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National…

We have developed an application of a one-dimensional micro-strip detector for capturing x-ray diffraction data in pulsed magnetic fields. This detector consists of a large array of 50 \mu m-wide Si strips with a full-frame read out at 20…

Instrumentation and Detectors · Physics 2015-05-30 Zahirul Islam , Jacob P. C. Ruff , Kate A. Ross , Hiroyuki Nojiri , Bruce D. Gaulin

We present the first detection of electrons with kinetic energy in the 100 eV range with transition-edge sensors (TESs). This has been achieved with a $(100\times 100)$ $\mu$m$^2$ Ti-Au bilayer TES, with a critical temperature of about 84…

Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…

Instrumentation and Methods for Astrophysics · Physics 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , D. A. Fischer , C. Jaye , Y. I. Joe , G. C. O'Neil , D. S. Swetz , J. N. Ullom

We present measurements of the electrical and thermal properties of new arrays of bolometeric detectors that were fabricated as part of a program to develop bolometers optimized for the low photon background of the EBEX balloon-borne…

Instrumentation and Methods for Astrophysics · Physics 2009-08-17 Johannes Hubmayr , Francois Aubin , Eric Bissonnette , Matt Dobbs , Shaul Hanany , Adrian T. Lee , Kevin MacDermid , Xiaofan Meng , Ilan Sagiv , Graeme Smecher

Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…

Instrumentation and Detectors · Physics 2023-05-11 K. M. Patel , S. Withington , C. N. Thomas , A. G. Shard , D. J. Goldie

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this…

Accurate temperature measurement at the nanoscale is crucial for thermal management in next-generation microelectronic devices. Existing optical and scanning-probe thermometry techniques face limitations in spatial resolution, accuracy, or…

Recent advances in CMOS imaging sensor technology , e.g. in CMOS pixel sensors, have proven that the CMOS process is radiation tolerant enough to cope with certain radiation levels required for tracking layers in hadron collider…

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology which combines their signals over a reduced number of wires and amplifiers. In this Letter, we present and demonstrate a multiplexer design…

In the early 2030s, ESAs new X-ray observatory, Athena, is scheduled to be launched. It will carry two main instruments, one of which is the X-ray Integral Field Unit (X-IFU), an X-ray imaging spectrometer, which will consist of an array of…

X-ray transition radiation can be used to measure the Lorentz factor of relativistic particles. Standard transition radiation detectors (TRDs) typically incorporate thin plastic foil radiators and gas-filled x-ray detectors, and are…

High Energy Physics - Experiment · Physics 2009-11-07 Gary L. Case , P. Parker Altice , Michael L. Cherry , Joachim Isbert , John W. Mitchell , Donald Patterson

We report initial measurements on our firstMoAu Transition Edge Sensors (TESs). The TESs formed from a bilayer of 40 nm of Mo and 106 nm of Au showed transition temperatures of about 320 mK, higher than identical TESs with a MoCu bilayer…

Instrumentation and Detectors · Physics 2014-01-13 D. J. Goldie , A. V. Velichko , D. M. Glowacka , S. Withington

This paper presents the results of a study of the response of a test CMOS sensor with a radiation tolerant pixel cell design to 80 keV and 100 keV electrons. The point spread function is measured to be (13.0+/- 1.7) microns at 100 keV and…

Instrumentation and Detectors · Physics 2009-06-25 Marco Battaglia , Devis Contarato , Peter Denes , Dionisio Doering , Velimir Radmilovic

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated…

Instrumentation and Detectors · Physics 2025-02-19 Panthita Triamkitsawat , Tejas Guruswamy , Orlando Quaranta , Lisa Gades , Umeshkumar Patel , Antonino Miceli