Related papers: Electrometer calibration with sub-part-per-million…
Nanoscale single-electron pumps can be used to generate accurate currents, and can potentially serve to realize a new standard of electrical current based on elementary charge. Here, we use a silicon-based quantum dot with tunable tunnel…
Due to the large dynamic ranges involved with separating the cosmological 21-cm signal from the Cosmic Dawn from galactic foregrounds, a well-calibrated instrument is essential to avoid biases from instrumental systematics. In this paper we…
An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in…
We describe three fundamentally different methods we have applied to calibrate the test mass displacement actuators to search for systematic errors in the calibration of the LIGO gravitational-wave detectors. The actuation frequencies…
This study demonstrates a significant enhancement in ultra-low-frequency (ULF) electric field sensitivity using Rydberg atoms via an optical chopping amplification (OCA) technique. Conventional Rydberg-based ULF measurements are…
We present an optomechanical accelerometer with high dynamic range, high bandwidth and read-out noise levels below 8 ${\mu}$g/$\sqrt{\mathrm{Hz}}$. The straightforward assembly and low cost of our device make it a prime candidate for…
For glucose electrochemical sensors, a comprehensive electronics interface is designed and constructed in 0.18 um, CMOS process technology, and 1.5 V supply voltage. This interface includes a programmable readout amplifier and bandgap…
In this study, we evaluate the suitability of using DC-biased aluminium resonators as low-frequency kinetic inductance detectors operating in the frequency range of 50 - 120 GHz. Our analysis routine for supercurrent-biased resonators is…
This paper describes a novel method for calibrating dc-precise magnetometers in the low field range (100 uT), which gives acceptable results even in laboratory conditions with significant magnetic interference. By introducing a closely…
This paper demonstrates designing and developing of an Ultra-Low Noise Amplifier which should potentially increase the sensitivity of the existing Magnetic Resonance Imaging (MRI) systems. The Design of the LNA is fabricated and…
This paper describes hardware and software improvements of the INRIM coaxial microcalorimeter together with their outcome on the primary power standard realization in the frequency band 0.05 - 40 GHz. A better temperature and power…
A method to precisely calibrate the oscillation amplitude in Dynamic Scanning Force Microscopy is described. It is experimentally shown that a typical electronics used to process the dynamic motion of the cantilever can be adjusted to…
We make two contributions to the problem of estimating the $L_1$ calibration error of a binary classifier from a finite dataset. First, we provide an upper bound for any classifier where the calibration function has bounded variation.…
Low-noise cryogenic microwave amplifiers are widely used in applications such as radio astronomy and quantum computing. On-wafer noise characterization of cryogenic low-noise transistors is desirable because it facilitates more rapid…
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident…
Machine learning models deployed in real-world applications are often evaluated with precision-based metrics such as F1-score or AUC-PR (Area Under the Curve of Precision Recall). Heavily dependent on the class prior, such metrics make it…
Accurate power measurements of electronic components operating at high frequencies are vital in determining where power losses occur in a system such as a power converter. Such power measurements must be carried out with equipment that can…
There is a need for techniques for efficient and accurate measurement of the impedance of rechargeable batteries at extra-low frequencies (ELFs, typically below 10uHz), as these reflect real usage and cycling patterns, and their importance…
Low-noise temperature measurements at frequencies in the milli-Hertz range are needed in the LISA and LISA PathFinder (LPF). The required temperature stability for LISA is around 10 uK/sqrt(Hz) at frequencies down to 0.1 mHz. In this paper…
We propose a new type of cryogenic current amplifiers, in which low-frequency power spectrum of current can be measured through a measurement of microwave response of a superconducting resonant circuit shunted by a series array of Josephson…