Related papers: A Highly Linear Calibration Metric for TES X-ray M…
The motivation for PF calorimetry is to experimentally measure the energy of hadron jets with excellent resolution. In particle flow designs, sigma(E)/E < 5% should be possible for a range of jet energies from 50 GeV to 250 GeV, important…
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This…
Phosphor imaging plates (IPs) have been calibrated and proven useful for quantitative x-ray imaging in the 1 to over 1000 keV energy range. In this paper we report on calibration measurements made at XUV energies in the 60 to 900 eV energy…
The two output signals of quadrature phase interferometers allow to benefit both from the high sensitivity of interferometry (working inside a fringe) and from an extended input range (counting fringes). Their calibration to reach a linear…
We propose a robust calibration pipeline that optimises the selection of calibration samples for the estimation of calibration parameters that fit the entire scene. We minimise user error by automating the data selection process according…
An innovative path for the detectors at future colliders to achieve higher performances is to use a Particle Flow approach, which requires highly granular calorimeters to image individual showers. The silicon-tungsten electromagnetic…
A novel approach to calibrate the sensitivity of a differential thermometer, consisting of several thermocouples connected in series (thermopile), has been developed. The goal of this method is to increase the accuracy of small temperature…
Accurate wavelength calibration is an important factor for any measurement with high resolution spectrographs. Stellar spectrum comprises of discrete absorption or emission lines whose position is precisely determined by calibrating the…
Sufficient energy resolution is the key issue for the calorimetry in particle and nuclear physics. The calorimeter of the A4 parity violation experiment at MAMI is a segmented calorimeter where the energy of an event is determined by…
The operation and performance of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) are presented, based on data collected in pp collisions at $\sqrt{s}$ = 13 TeV at the CERN LHC, in the years from 2015 to 2018 (LHC Run 2),…
We report on the MIT Epoch of Reionization (MITEoR) experiment, a pathfinder low-frequency radio interferometer whose goal is to test technologies that improve the calibration precision and reduce the cost of the high-sensitivity 3D mapping…
In the recent literature on machine learning and decision making, calibration has emerged as a desirable and widely-studied statistical property of the outputs of binary prediction models. However, the algorithmic aspects of measuring model…
Atomic force microscopy (AFM) is an analytical surface characterization tool which can reveal a sample's topography with high spatial resolution while simultaneously probing tip-sample interactions. Local measurement of chemical properties…
The first stage of the FCC (Future Circular Collider) is a high-luminosity electron-positron collider (FCC-ee) with centre-of-mass energy ranging from 88 to 365 GeV, to study with high precision the Z, W, Higgs and top particles, with…
We present work on quantifying the minimum requirements for beam polarization precision at future $e^+e^-$ Higgs factories. We find that, under the assumption of a high electron beam polarization ($P_-$) that the positron polarization…
Excalibur is a non-parametric, hierarchical framework for precision wavelength-calibration of spectrographs. It is designed with the needs of extreme-precision radial velocity (EPRV) in mind, which require that instruments be calibrated or…
We present the photometric calibration of the twelve optical passbands observed by the Javalambre Photometric Local Universe Survey (J-PLUS). The proposed calibration method has four steps: (i) definition of a high-quality set of…
An improved method of energy calibration of position-sensitive silicon detector is presented. Instead of the parabolic function used in traditional method, a new function describing the relation of position and energy is introduced and…
This paper presents the prospects of measuring $\sigma(e^{+}e^{-}\to ZH)\times Br(H \to \gamma\gamma)$ in 3 $Z$ decay channels $Z \to q\bar{q} / \mu^{+} \mu^{-} / \nu\bar{\nu}$ using the baseline detector with $\sqrt{s} = 240 GeV$ at the…
The thermal sensitive electrical parameter (TSEP) method is crucial for enhancing the reliability of power devices through junction temperature monitoring. The TSEP method comprises three key processes: calibration, regression, and…