English
Related papers

Related papers: A Highly Linear Calibration Metric for TES X-ray M…

200 papers

Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…

Instrumentation and Methods for Astrophysics · Physics 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , D. A. Fischer , C. Jaye , Y. I. Joe , G. C. O'Neil , D. S. Swetz , J. N. Ullom

The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the…

Data Analysis, Statistics and Probability · Physics 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , J. Hays-Wehle , Y. -I. Joe , K. M. Morgan , G. C. O'Neil , C. D. Reintsema , D. R. Schmidt , J. N. Ullom , D. S. Swetz

Scanning thermal microscopy is a unique tool for the study of thermal properties at the nanoscale. However, calibration of the method is a crucial problem. When analyzing local thermal conductivity, direct calibration is not possible and…

Data Analysis, Statistics and Probability · Physics 2025-01-16 Anna Charvátová Campbell , Petr Klapetek , Radek Šlesinger , Jan Martinek , Václav Hortvík , Viktor Witkovský , Gejza Wimmer

We consider how to analyze microcalorimeter pulses for quantities that are nonlinear in the data, while preserving the signal-to-noise advantages of lin- ear optimal filtering. We successfully apply our chosen approach to compute the…

Instrumentation and Detectors · Physics 2018-04-18 J. W. Fowler , C. G. Pappas , B. K. Alpert , W. B. Doriese , G. C. O'Neil , J. N. Ullom , D. S. Swetz

The main task of an energy calibration is to find a relation between pulse-height values and the corresponding energies. Doing this for each pulse-height channel individually requires an elaborated input spectrum with an excellent counting…

Instrumentation and Detectors · Physics 2016-02-17 Daniel Maier , Olivier Limousin

All observations by the aperture photometer (PHT-P) and the far-infrared (FIR) camera section (PHT-C) of ISOPHOT included reference measurements against stable internal fine calibration sources (FCS) to correct for temporal drifts in…

We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…

Instrumentation and Detectors · Physics 2019-08-15 Jaroslav Zalesak

The European X-ray Free Electron Laser (XFEL.EU) will provide unprecedented peak brilliance and ultra-short and spatially coherent X-ray pulses in an energy range of 0.25 to 25 keV . The pulse timing structure is unique with a burst of 2700…

Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $\Delta E$ < 3 eV full-width-half-maximum (FWHM) in the soft…

Instrumentation and Methods for Astrophysics · Physics 2021-02-19 E. Taralli , M. D'Andrea , L. Gottardi , K. Nagayoshi , M. L. Ridder , M. de Wit , D. Vaccaro , H. Akamatsu , M. P. Bruijn , J. R. Gao

Optically levitated nanoparticles offer enormous potential for precision sensing. However, as for any other metrology device, the absolute measurement performance of a levitated-particle sensor is limited by the accuracy of the calibration…

With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over…

Optical transition-edge sensors have shown energy resolution for resolving the number of incident photons at the telecommunication wavelength. Higher energy resolution is required for biological imaging and microscope spectroscopy. In this…

Instrumentation and Detectors · Physics 2022-07-27 Kaori Hattori , Toshio Konno , Yoshitaka Miura , Sachiko Takasu , Daiji Fukuda

A silicon-based fine granularity calorimeter is a potential technology for the future International Linear Collider ILC, the future circular collider CEPC, and is also the chosen technology for the upgraded CMS experiment of the Large…

Instrumentation and Detectors · Physics 2017-08-02 Stathes Paganis , Andreas Psallidas , Arnaud Steen

The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce…

Instrumentation and Detectors · Physics 2025-02-19 Tejas Guruswamy , Orlando Quaranta , Lisa Gades , Umeshkumar Patel , Antonino Miceli

Ultra-sensitive cryogenic calorimeters have become a favored technology with widespread application where eV-scale energy resolutions are needed. In this article, we characterize the performance of an X-ray magnetic microcalorimeter (MMC)…

High Energy Physics - Experiment · Physics 2025-01-16 Francesco Toschi , Benedikt Maier , Greta Heine , Torben Ferber , Sebastian Kempf , Markus Klute , Belina von Krosigk

We study the calibration process in circular ultrasound tomography devices where the sensor positions deviate from the circumference of a perfect circle. This problem arises in a variety of applications in signal processing ranging from…

Machine Learning · Computer Science 2016-11-18 Reza Parhizkar , Amin Karbasi , Sewoong Oh , Martin Vetterli

The M\"ONCH hybrid pixel detector, with a 25 \textmu m pixel pitch and fast charge-integrating readout, has demonstrated subpixel resolution capabilities for X-ray imaging and deep learning-based electron localization in electron…

A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy…

Transition-edge sensors (TES) are photon-number resolving calorimetric spectrometers with near unit efficiency. Their recovery time, which is on the order of microseconds, limits the number resolving ability and timing accuracy in high…

Instrumentation and Detectors · Physics 2018-12-21 Jianwei Lee , Lijiong Shen , Alessandro Cerè , Thomas Gerrits , Adriana E. Lita , Sae Woo Nam , Christian Kurtsiefer

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a…

Instrumentation and Detectors · Physics 2026-05-26 William J. Matava , Michael R. Williams
‹ Prev 1 2 3 10 Next ›