Related papers: A Highly Linear Calibration Metric for TES X-ray M…
Whenever we use devices to take measurements, calibration is indispensable. While the purpose of calibration is to reduce bias and uncertainty in the measurements, it can be quite difficult, expensive, and sometimes even impossible to…
This paper provides an overview of the PACS photometer flux calibration concept, in particular for the principal observation mode, the scan map. The absolute flux calibration is tied to the photospheric models of five fiducial stellar…
A simple, self-calibrating, rotating-waveplate polarimeter is largely insensitive to light intensity fluctuations and is shown to be useful for determining the Stokes parameters of light. This study shows how to minimize the in situ…
For cross section measurements, an accurate knowledge of the integrated luminosity is required. The FCC-ee Z lineshape programme sets the ambitious precision goal of $10^{-4}$ on the \emph{absolute} luminosity measurement and one order of…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
The workhorse of atomic physics, quantum electrodynamics, is one of the best-tested theories in physics. However recent discrepancies have shed doubt on its accuracy for complex atomic systems. To facilitate the development of the theory…
This paper presents the electron and photon energy calibration obtained with the ATLAS detector using 140 fb$^{-1}$ of LHC proton-proton collision data recorded at $\sqrt{s}=13$ TeV between 2015 and 2018. Methods for the measurement of…
The FCC-ee aims to improve on electroweak precision measurements, with goals of 100 keV on the Z mass and width, and a fraction of MeV on the W mass. Compared to LEP, this implies a much improved knowledge of the centre-of-mass energy when…
Bolometric experiments searching for rare events usually require an extremely low radioactive background to prevent spurious signals from mimicking those of interest, spoiling the sensitivity of the apparatus. In such contexts, radioactive…
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses…
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges.…
Primary power standards in the microwave domain are realized using a calorimetric technique, usually identified with the used measurement system, i.e., the microcalorimeter. It is adjusted for measurement of power ratios with a relative…
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…
The Very Large Area Gamma-ray Space Telescope Pathfinder (VLAST-P), as the technology validation satellite for the VLAST mission, is designed to observe high-energy solar bursts on orbit. The CsI electromagnetic calorimeter (ECAL) is one of…
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with…
The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It is a key detector for the measurement of hadrons, jets, tau leptons and missing transverse energy. The…
This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb$^{-1}$ of LHC proton--proton collision data taken at centre-of-mass energies of $\sqrt{s}$ = 7 and 8 TeV. The reconstruction…
The Particle Flow Algorithms adopted for future $e^{+}e^{-}$ colliders detectors and phase-II CMS upgrade require very high granularity calorimeters to deconvolve the individual contributions of particles in jets. This is especially true…
Polarimetry with permille-level precision is essential for future electron-positron linear colliders. Compton polarimeters can reach negligible statistical uncertainties within seconds of measurement time. The dominating systematic…
A procedure has been developed for the charge, mass and energy calibration of ions produced in nuclear heavy ion reactions. The charge and mass identification are based on a $\Delta$E-E technique. A computer code determines the conversion…