Related papers: Novel MCP-Based Electron Source Studies
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used…
Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution,…
With their fast response time and a spatial resolution in the range of a few microns, microchannel plates (MCPs) are a prominent choice for the development of detectors with highest resolution standards. Amorphous silicon-based microchannel…
Multi Micro-Channel-Plate Photomultiplier tubes (MCP-PMT) with High Collection Efficiency (Hi-CE) MCPs are developed and characterised. With these Hi-CE MCPs more than 90% of photoelectrons emitted from the photocathode can be detected;…
A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…
Nowadays, Microchannel Plate (MCP), as a kind of electron multipliers based on the secondary electron emission, is widely used in many high-sensitive experiments, such as neutrino detection, which require the noise to be as low as possible,…
Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area…
We report on an apparatus able to measure the absolute detection efficiency of a detector for electrons in the 30 - 900 eV range. In particular, we discuss the characterisation of a two-stage chevron microchannel plate (MCP). The…
We present a comprehensive characterization of the LAPPD Gen-II, a large-area microchannel-plate photomultiplier tube (MCP-PMT) equipped with a capacitively coupled sensing (readout) electrode. Two detector variants with different…
Microchannel plates (MCPs) were the driving detector technology for ultraviolet (UV) astronomy over many years, and still today MCP-based detectors are the baseline for several planned UV instruments. The development of advanced MCP…
A pulsed electron gun that can produce MHz repetition rate nanosecond pulses is described. The gun uses a Pierce grid in combination with an anode to extract electrons from a tungsten filament cathode. The electrons emerging from the anode…
The Argonne micro-channel plate photomultiplier tube (MCP-PMT) is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein \mbox{6 $\times$ 6 cm$^2$} sized detectors are made at Argonne National Laboratory.…
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time…
Experimental measurements of the radial spreading of photoelectrons emitted from a multi-alkali photocathode in a MCP-based photomultiplier tube have shown that, for photon wavelengths of 455 nm, 515 nm and 625 nm, the maximum initial…
Microchannel plate photodetectors provide both picosecond time resolution and sub-millimeter position resolution, making them attractive photosensors for particle identification detectors of a future U.S. Electron Ion Collider. We have…
Jinping Neutrino Experiment plans to deploy a new type of 8-inch MCP-PMT with high photon detection efficiency for MeV-scale neutrino measurements. This work studies the performance of the MCP-PMTs, including the photon detection…
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is…
A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…
The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an…
Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility…