English
Related papers

Related papers: Novel MCP-Based Electron Source Studies

200 papers

The Argonne MCP-based photo detector is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein 6 cm x 6 cm sized detectors are made at Argonne National Laboratory. We have successfully built and tested our first…

Millicharged particles (MCPs) arise in many well-motivated extensions of the Standard Model and are a popular subject for experimental searches. We investigate attenuation of the MCP flux produced at accelerator experiments due to their…

High Energy Physics - Phenomenology · Physics 2022-09-14 Nataliya Arefyeva , Sergei Gninenko , Dmitry Gorbunov , Dmitry Kirpichnikov

We study the production of exotic millicharged particles (MCPs) from cosmic ray-atmosphere collisions which constitutes a permanent MCP production source for all terrestrial experiments Our calculation of the MCP flux can be used to…

High Energy Physics - Phenomenology · Physics 2021-01-04 Ryan Plestid , Volodymyr Takhistov , Yu-Dai Tsai , Torsten Bringmann , Alexander Kusenko , Maxim Pospelov

The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…

Instrumentation and Detectors · Physics 2019-07-23 M. Nizam , B. Satyanarayana , R. R. Shinde , G. Majumder

In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $\pi$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent…

Minicharged particles (mCPs), hypothetical free particles with effective electric charges much smaller than the elementary charge, $e$, offer a valuable probe of dark sectors and fundamental physics through several clear experimental…

High Energy Physics - Phenomenology · Physics 2026-05-13 Marc de Montigny , Pierre-Philippe A. Ouimet , James Pinfold , Ameir Shaa , Michael Staelens

An electrostatic time-of-flight detector named E-MCP has been developed for quick diagnostics of circulating beam and timing measurement in mass spectrometry at the Rare-RI Ring in RIKEN. The E-MCP detector consists of a conversion foil,…

The linearity of charge response is an important feature of photomultiplier tubes (PMT) for physics measurements, especially the newly developed 20" MCP-PMT. In this paper, in addition to the traditional method of double light sources, we…

Instrumentation and Detectors · Physics 2022-12-23 Diru Wu , Fengjiao Luo , Zhimin Wang , Min Li , Jilei Xu , Miao He , Changgen Yang , Yuekun Heng

Results from the Modified Three Gradient Method (MTGM), applied to a pulsed high intensity electron source, are presented. The MTGM makes possible the non-destructive determination of beam emittance in the space charge presence [1]. We…

Accelerator Physics · Physics 2007-05-23 S. Marghitu , C. Oproiu , C. Dinca , O. Marghitu

A novel parallel plate model is proposed that divided the electron cloud into three parts at saturation, and it is studied in detail using both an analytical approach and PIC (Particle In Cell) code simulations. As one part of the electron…

Accelerator Physics · Physics 2015-06-19 Lang Liao , Meng Zhang , Minghua Zhao

We are developing imaging and photon counting UV-MCP detectors, which are sensitive in the wavelength range from far ultraviolet to near ultraviolet. A good quantum efficiency, solar blindness and high spatial resolution is the aim of our…

We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects,…

In this paper we describe the technical implementation of pump-probe cathodoluminescence microscopy (PP-CL), a novel technique for studying ultrafast dynamics in materials using combined excitation of electron and laser pulses. The PP-CL…

Instrumentation and Detectors · Physics 2021-12-07 Magdalena Solà-Garcia , Kelly W. Mauser , Nika van Nielen , Toon Coenen , Sophie Meuret , Albert Polman

We report on a novel electro-optic device for the diagnostics of high repetition rate laser systems. It is composed of a microwave receiver and of a second order nonlinear crystal, whose irradiation with a train of short laser pulses…

Optics · Physics 2014-03-05 C. Braggio , A. F. Borghesani

We report on spectroscopy and time-of-flight measurements using an 18 keV fast-pulsed photoelectron source of adjustable intensity, ranging from single photoelectrons per pulse to 5 photoelectrons per microsecond at pulse repetition rates…

Instrumentation and Detectors · Physics 2009-06-19 K. Valerius , M. Beck , H. Arlinghaus , J. Bonn , V. M. Hannen , H. Hein , B. Ostrick , S. Streubel , Ch. Weinheimer , M. Zboril

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…

Instrumentation and Detectors · Physics 2017-09-20 B. B. Wiggins , Varinderjit Singh , J. Vadas , J. Huston , T. K. Steinbach , S. Hudan , R. T. deSouza

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…

Instrumentation and Detectors · Physics 2008-11-26 A. Di Mauro , B. Lund-Jensen , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , L. Periale , P. Picchi , F. Pietropaolo , I. Rodionov , J. C. Santiard

High-brightness electron sources are a key ingredient to the development of compact accelerator-based light sources. The electron sources are commonly based on (linear) photoemission process where a laser pulse with proper wavelength…

Accelerator Physics · Physics 2016-08-08 Anusorn Lueangaramwong , Daniel Mihalcea , Gerard Andonian , Philippe Piot

We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides…

Instrumentation and Detectors · Physics 2022-01-26 M. Follin , R. Chyzh , C. -H. Sung , D. Breton , J. Maalmi , T. Chaminade , E. Delagnes , K. Schäfers , C. Weinheimer , D. Yvon , V. Sharyy

In this paper, we review and compare HPM sources operating without a magnetic field to guide the electron beam that are capable of producing high-power microwave (HPM) pulses with a duration of about 100 ns. The proposed analysis summarizes…

Accelerator Physics · Physics 2022-11-11 S. Anishchenko , V. Baryshevsky , A. Gurinovich , E. Gurnevich , P. Molchanov , A. Rouba