English
Related papers

Related papers: Time resolution of silicon pixel sensors

200 papers

In this report, we derive analytical expressions for the time resolution limits of standard silicon sensors, LGADs, and 3D trench sensors. We separately examine the effects of Landau fluctuations and electronic noise. To analyze Landau…

High Energy Physics - Experiment · Physics 2025-04-04 Werner Riegler

First measurements are presented from a newly commissioned two-photon absorption (TPA) setup at Nikhef. The characterisation of the various components of the system is discussed. Two planar silicon sensors, one being electron collecting and…

Instrumentation and Detectors · Physics 2022-02-23 R. Geertsema , K. Akiba , M. van Beuzekom , T. Bischoff , K. Heijhoff , H. Snoek

In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…

SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of…

In this paper the results of a beam test characterization campaign of 3D trench silicon pixel sensors are presented. A time resolution in the order of 10 ps was measured both for non-irradiated and irradiated sensors up to a fluence of $2.5…

Instrumentation and Detectors · Physics 2023-02-08 A. Lampis , F. Borgato , D. Brundu , A. Cardini , G. M. Cossu , G. -F. Dalla Betta , M. Garau , L. La Delfa , A. Lai , A. Loi , M. Obertino , G. Simi , S. Vecchi

We address the determination of the time resolution for the $\rm 100~\mu m$ 4H-SiC PIN detectors fabricated by Nanjing University (NJU). The time response to $\rm \beta$ particles from a $\rm ^{90}$Sr source is investigated for the…

Instrumentation and Detectors · Physics 2022-04-05 Tao Yang , Yuhang Tan , Qing Liu , Suyu Xiao , Kai Liu , Jianyong Zhang , Ryuta Kiuchi , Mei Zhao , Xiyuan Zhang , Congcong Wang , Boyue Wu , Jianing Lin , Weimin Song , Hai Lu , Xin Shi

A silicon 3D detector with a single cell of 50x50 um2 was produced and evaluated for timing applications. The measurements of time resolution were performed for 90Sr electrons with dedicated electronics used also for determining time…

Instrumentation and Detectors · Physics 2019-06-26 G. Kramberger , V. Cindro , D. Flores , S. Hidalgo , B. Hiti , M. Manna , I. Mandić , M. Mikuž , D. Quirion , G. Pellegrini , M. Zavrtanik

The timing performance of the Timepix4 application-specific integrated circuit (ASIC) bump-bonded to a $100\;\mu\textrm{m}$ thick n-on-p silicon sensor is presented. A picosecond pulsed infrared laser was used to generate electron-hole…

The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained…

Instrumentation and Detectors · Physics 2022-09-21 Marco Alberto Ayala-Torres , Luis Manuel Montaño Zetina , Marcos Fontaine Sánchez

The Micro-Pattern Gaseous Detectors offer excellent spatial and temporal resolution in harsh radiation environments of high-luminosity colliders. In this work, an attempt has been made to establish an algorithm for estimating the time…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sudeb Bhattacharya

Timepix3 is a multi-purpose readout ASIC for hybrid pixel detectors. It can measure time and energy simultaneously by employing time-of-arrival (ToA) and time-over-threshold (ToT) techniques. Both methods are systematically affected by…

A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…

The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a…

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…

Instrumentation and Detectors · Physics 2021-09-08 Alexey Stoykov , Tigran Rostomyan

The design of a detector system comprised of four silicon sensors bump-bonded to Timepix4 ASICs is described together with its data acquisition system, operational infrastructure, and dedicated software. The spatial and temporal performance…

This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with…

A closed-form approximate expression is presented for the short time-frame development of silicon diode sensor signals in the context of high frame-rate detection of incident X-ray fluxes, in the limit that the X-ray absorption profile…

Instrumentation and Detectors · Physics 2020-04-22 Bruce A. Schumm

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…

Instrumentation and Detectors · Physics 2014-10-17 Paolo W. Cattaneo , Matteo De Gerone , Flavio Gatti , Miki Nishimura , Wataru Ootani , Massimo Rossella , Yusuke Uchiyama

Results in this paper present an in-depth study of time resolution for active pixels of the RD50-MPW2 prototype CMOS particle detector. Measurement techniques employed include Backside- and Edge-TCT configurations, in addition to electrons…