Related papers: Time resolution of silicon pixel sensors
Time-resolved studies have so far relied on rapidly triggering a photo-induced dynamic in chemical or biological ions or molecules and subsequently probing them with a beam of fast moving photons or electrons that crosses the studied…
Test beam measurements have been carried out with a 3D sensor on a Timepix3 ASIC and the time measurements are presented. The measurements are compared to those of a thin planar sensor on Timepix3. It is shown that for a perpendicularly…
The direct response of Silicon PhotoMultipliers being traversed by a MIP charged particle have been studied in a systematic way for the first time. Using beam test data, time resolution and the crosstalk probability have been measured. A…
We present a concept to improve the spatial resolution of silicon pixel-detectors via the implementation of a sub-pixel cross-coupling, which introduces directional charge sharing between pixels. The charge-collection electrode is segmented…
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…
This study evaluates the radiation tolerance of a 4H-SiC PIN detector under X-ray irradiation up to \SI{2}{MGy} (Si) at \SI{160}{keV}. The detector features a fully epitaxial vertical PIN structure with mesa terminations and field plates.…
Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders requires the use of time information in tracking, due to the increasing levels…
A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…
Silicon sensors with high time resolution can help particle identification in the International Linear Collider (ILC). We are studying Low Gain Avalanche Diodes (LGADs) as a high timing resolution sensor. As a step to develop LGADs, we are…
The spatial and temporal performance of a telescope system comprising planar silicon sensors bump-bonded to Timepix4-v2 ASICs are assessed at the CERN SPS using a $180$~GeV/$c$ mixed hadron beam. The pointing resolution at the centre of the…
A graphene-optimized silicon carbide PIN detector was fabricated and its radiation tolerance under X-ray irradiation of 160 keV was evaluated. Its electrical properties, charge collection performance and time resolution of beta-particles…
The time resolution for a charged particle detection is reported for a typical scintillating fiber detector instrumented with Rockwell HISTE-IV Visible Light Photon Counters. The resolution measurements are shown to agree with a simple…
A detailed and accurate characterisation of silicon photomultiplier detectors is required for a better understanding of the signal and noise in many applications. The collected information is a valuable feedback to the manufacturers in…
The bulk displacement damage in the detector, produces effects at the device level that limits the long time utilisation of detectors as position sensitive devices and thus the lifetime of detector systems. So, the prediction of time…
We present time-resolved charge sensing measurements on a GaAs double quantum dot with two proximal quantum point contact (QPC) detectors. The QPC currents are analyzed with cross-correlation techniques, which enables us to measure dot…
The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure,…
This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a ${}^{90}$Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61~ps was achieved,…
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber ({\mu}PIC) coupled with a field-programmable-gate-array-based data acquisition system. Our…
Silicon carbide detectors exhibit good detection performance such as fast time resolution, high radiation tolerances, high breakdown voltage and low temperature sensitivity and have been studied for detection applications. Meanwhile,…
We have been developing X-ray SOIPIXs for next-generation satellites for X-ray astronomy. Their high time resolution ($\sim10~\mu$s) and event-trigger-output function enable us to read out without pile-ups and to use anti-coincidence…