Related papers: Study on temperature coefficient of CdTe detector …
By developing a two-dimensional (2D) full quantum simulation, the attributes of carbon nanotube field-effect transistors (CNTFETs) in different temperatures have been comprehensively investigated. Simulations have been performed by…
Simulation studies and spectroscopic measurements are presented regarding the development of a pixel multilayer CdTe detector under development in the context of the COCAE project. The instrument will be used for the localization and…
An in-house Seebeck coefficient measurement system has been developed which can measure the thermoemf (Seebeck coefficient) of the sample, under large temperature difference, in the temperature range 300-600 K. Unlike majority of reported…
Applications that utilize scintillation detectors at low temperatures are growing in number. Many of these require materials with high light yield and a fast response. Here we report on the low-temperature characterisation of ZnSe doped…
This work introduces a thermoreflectance-based system designed to measure the surface temperature field of activated microelectronic devices at submicron spatial resolution with either a laser or a CCD camera. The article describes the…
In recent years cooling technology for Liquid Xenon (LXe) detectors has advanced driven by the development of Dark Matter (DM) detectors with target mass in the 100 - 1,000 kg range. The next generation of DM detectors based on LXe will be…
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…
Elemental materials provide clean and fundamental platforms for studying superconductivity. However, the highest superconducting critical temperature (Tc) yet observed in elements has not exceeded 30 K. Discovering elemental superconductors…
Cryogenic microcalorimeters are key tools for high-resolution X-ray spectroscopy due to their excellent energy resolution and quantum efficiency close to 100%. Multiple types of microcalorimeters exist, some of which have already proven…
Polarization detection of X-rays is a non-negligible topic to astrophysical observation. Many polarization detection methods have been well developed for X-rays in the energy range below 10~keV, while the detection at 10-30~keV is rarely…
On-chip thermometry at deep-cryogenic temperatures is vital in quantum computing applications to accurately quantify the effect of increased temperature on qubit performance. In this work, we present a sub-1 K temperature sensor in CMOS…
This review presents an overview of the thermal properties of mesoscopic structures. The discussion is based on the concept of electron energy distribution, and, in particular, on controlling and probing it. The temperature of an electron…
This work presents a self-heating study of a 40-nm bulk-CMOS technology in the ambient temperature range from 300 K down to 4.2 K. A custom test chip was designed and fabricated for measuring both the temperature rise in the MOSFET channel…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…
The Nab experiment aims to extract the neutron beta decay correlation coefficients 'a' and 'b'. This will be accomplished using a 7 m tall electromagnetic spectrometer which measures electron energies and proton momenta. Detection of…
Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through…
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um…
The key parameters of Cherenkov Correlated Timing (CCT) detectors are discussed. Measurements of radiator geometry, optical properties of radiator and coupling materials, and photon detector timing performance are presented.
Transition-edge sensors are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically…
Since the initial exploration of soft gamma-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation…