Related papers: Study on temperature coefficient of CdTe detector …
We present systematic measurements of the temperature-dependence of detection efficiencies in TaN and NbN superconducting nanowire single-photon detectors. We have observed a clear increase of the cut-off wavelength with decreasing…
Cryogenic detectors have a long history of success in the field of rare event searches. In particular scintillating calorimeters are very suitable detectors for this task since they provide particle discrimination: the simultaneous…
CdTe is increasingly being used as the x-ray sensing material in imaging pixel array detectors for x-rays, generally above 20 keV, where silicon sensors become unacceptably transparent. Unfortunately CdTe suffers from polarization, which…
The brightness temperature is an effective parameter that describes the physical properties of emitting material in astrophysical objects. It is commonly determined by imaging and modeling the structure of the emitting region and estimating…
The Fine Pixel CCD (FPCCD) is one of the candidate sensor technologies for the ILC vertex detector. It will be located near interaction point and require high radiation tolerance. It will thus be operated at -40 degree C to improve…
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read…
Isotope thermometry, widely used to measure the temperature of a hot nuclear system formed in energetic nuclear collisions, is examined in the light of S-matrix approach to the nuclear equation of state of disassembled nuclear matter.…
This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…
Low-cost thermal cameras are inaccurate (usually $\pm 3^\circ C$) and have space-variant nonuniformity across their detector. Both inaccuracy and nonuniformity are dependent on the ambient temperature of the camera. The goal of this work…
Cadmium zinc telluride (CZT) detectors offer excellent room-temperature energy resolution, making them well suited for X- and $\gamma$-ray spectroscopy in challenging environments. Within the SIDDHARTA-2 program at the DA$\Phi$NE collider,…
Transition Radiation (TR) plays an important role in particle identification in high-energy physics and its characteristics provide a feasible method of energy calibration in the energy range up to 10 TeV, which is of interest for dark…
Debye temperature, TD, of Fe100-xCrx disordered alloys with 0<x<99.9 was determined from the temperature dependence of the centre shift of 57Fe Mossbauer spectra recorded in the temperature range of 80-300K. Its compositional dependence…
In recent years, the performance of Scientifc Complementary Metal Oxide Semiconductor (sCMOS) sensors has been improved signifcantly. Compared with CCD sensors, sCMOS sensors have various advantages, making them potentially better devices…
The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge…
In this paper the methodology and the results of a quasi real-time thermal characterization tool and method for the temperature mapping of circuits and boards based on sensing the infrared radiation will be introduced. With the proposed…
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have…
Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of…
The Debye temperature, T_D, of sigma-phase Fe_(100-x)Mo_x compounds with 47 < x < 56.7 was determined from the temperature dependence of the centre shift of M\"ossbauer spectra recorded in the temperature range of 80 - 300 K. Its…
The CCAT Observatory's Fred Young Submillimeter Telescope (FYST) is designed to observe submillimeter astronomical signals with high precision, using receivers fielding state-of-the-art kinetic inductance detector (KID) arrays. Mod-Cam, a…
Cadmium Telluride (CdTe) is a high-Z material with excellent photon radiation absorption properties, making it a promising material to include in radiation detection technologies. However, the brittleness of CdTe crystals as well as their…