Related papers: Study on temperature coefficient of CdTe detector …
X-ray transition radiation can be used to measure the Lorentz factor of relativistic particles. At energies approaching gamma = E/mc^2 = 10^5, transition radiation detectors (TRDs) can be optimized by using thick (sim 5 - 10 mil) foils with…
X-ray calorimetric sample platforms combining specific heat and synchrotron x-ray measurements provide a powerful means to investigate fundamental material properties. Calorimeter cell designs featuring a compact heater and thermometer…
We present a method from an X-ray observation of a galaxy cluster to measure the radial profile of the dark matter velocity dispersion, sigma_DM, and to compare the dark matter ``temperature'' defined as mu m_p sigma_DM**2 / k_B with the…
The development of cryogenic calorimeters was originally motivated by the fact that very low energy thresholds and excellent energy resolutions can be achieved by these devices. Cryogenic devices are widely used in double beta decay…
Distributed temperature sensors (DTS) measure temperatures by means of optical fibers. Those optoelectronic devices provide a continuous profile of the temperature distribution along the cable. Initiated in the 1980s, DTS systems have…
We investigate Coulomb blockade thermometers (CBT) in an intermediate temperature regime, where measurements with enhanced accuracy are possible due to the increased magnitude of the differential conductance dip. Previous theoretical…
We experimentally investigate the performance of NbTiN superconducting nanowire single photon detectors above the base temperature of a conventional Gifford-McMahon cryocooler (2.5 K). By tailoring design and thickness (8 - 13 nm) of the…
Diffuse X-ray Explorer (DIXE) is a proposed X-ray spectroscopic survey experiment for the China Space Station. Its detector assembly (DA) contains the transition edge sensor (TES) microcalorimeter and readout electronics based on the…
X-ray Thomson scattering (XRTS) is a common diagnostic used in the warm dense matter (WDM) regime to estimate plasma parameters like density, temperature and charge state. Experimental analysis typically relies on a forward model to obtain…
CdZnTe-based detectors are highly valued because of their high spectral resolution, which is an essential feature for nuclear medical imaging. However, this resolution is compromised when there are substantial defects in the CdZnTe…
The average pixel distance as well as the relative orientation of an array of 6 CCD detectors have been measured with accuracies of about 0.5 nm and 50 $\mu$rad, respectively. Such a precision satisfies the needs of modern crystal…
In this work a set of simulations that aim at the optimization of gaseous detectors for applications in X-ray fluorescence imaging in the energy range of 3 -- 30keV is presented. By studying the statistical distribution of the radiation…
Bridgman CdTe and CdZnTe crystal growth, with cadmium vapor pressure control, is applied to production of semiconductor gamma radiation detectors. Crystals are highly donor doped and highly electrically conducting. Annealing in tellurium…
This study investigates the temperature-induced hysteretic behavior of resistivity and magnetoresistance in electrodeposited bismuth films, with a focus on their application as absorbers in transition-edge sensors (TESs) for X-ray…
The paper describes a method for measuring the thermal diffusivity of materials having a high thermal conductivity. The apparatus is rather simple and low-cost, being therefore suitable in a laboratory for undergraduate students of…
We report the cooling of electrons in nanoelectronic Coulomb blockade thermometers below 4 mK. Above 7 mK the devices are in good thermal contact with the environment, well isolated from electrical noise, and not susceptible to…
Carrier Selective (CS) Silicon solar cells are increasingly explored as a low cost alternative to PN junction Silicon solar cells. While the recent trends on power conversion efficiency are encouraging, the temperature coefficient and hence…
We report on the progress in characterization of the Hamamatsu model R11410-21 Photomultiplier tubes (PMTs) for XENON1T dark matter experiment. The absolute quantum efficiency (QE) of the PMT was measured at low temperatures down to -110…
Thermal transient measurement based on source-drain voltage is a standard method to characterize thermal properties of silicon semiconductors but is doubtful to be directly applied to silicon carbide (SiC) devices. To evaluate its…
The temperature distribution in the battery significantly impacts the short-term and long-term performance of battery systems. Therefore, efficient, safe, and reliable battery system operation requires an accurate estimation of the…