English
Related papers

Related papers: Demonstration of single-shot picosecond time-resol…

200 papers

We propose a use of the self-seeding scheme with single crystal monochromator to produce high power, fully-coherent pulses for applications at a dedicated bio-imaging beamline at the European X-ray FEL in the photon energy range between 3.5…

Accelerator Physics · Physics 2012-07-10 Gianluca Geloni , Vitali Kocharyan , Evgeni Saldin

The generation of low-emittance electron beams has received significant interest in recent years. Driven by the requirements of X-ray free electron lasers, the emittance of photocathode injectors has been reduced significantly, with a…

Multi-pass transmission electron microscopy (MPTEM) has been proposed as a way to reduce damage to radiation-sensitive materials. For the field of cryo-electron microscopy (cryo-EM), this would significantly reduce the number of projections…

Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile,…

Instrumentation and Detectors · Physics 2020-05-06 B. Steffen , Ch. Gerth , M. Caselle , M. Felber , T. Kozak , D. R. Makowski , U. Mavrič , A. Mielczarek , P. Peier , K. Przygoda , L. Rota

In this work, we present the implementation of all-optical method for directly measuring electron pulse duration in an ultrafast scanning electron microscope. Our approach is based on the interaction of electrons with the ponderomotive…

We present feasibility study of an accelerator-based ultrafast transmission electron microscope (u-TEM) capable of producing a full field image in a single-shot with simultaneous picosecond temporal resolution and nanometer spatial…

Accelerator Physics · Physics 2014-06-11 D. Xiang , F. Fu , J. Zhang , X. Huang , L. Wang , X. Wang , W. Wan

The wavefront measurement of a light beam is a complex task, which often requires a series of spatially resolved intensity measurements. For instance, a detector array may be used to measure the local phase gradient in the transverse plane…

We report on a novel electro-optic device for the diagnostics of high repetition rate laser systems. It is composed of a microwave receiver and of a second order nonlinear crystal, whose irradiation with a train of short laser pulses…

Optics · Physics 2014-03-05 C. Braggio , A. F. Borghesani

We present a nano-scale photoelectron source, optimized towards ultrashort pulse durations and well-suited for time-resolved diffraction experiments. A tungsten tip, mounted in a suppressor-extractor electrode configuration, allows the…

Dynamic scattering and imaging with coherent, ultrafast, extreme ultraviolet (EUV) light sources can resolve charge, phonon and spin processes on their intrinsic length and time scales. However, full field coherent diffraction imaging…

We propose a novel approach for efficient tuning of optical properties of a high refractive index subwavelength nanoparticle with a magnetic Mie-type resonance by means of femtosecond laser irradiation. This concept is based on ultrafast…

The techniques for optical calibration of Jefferson Lab's large-acceptance magnetic hadron spectrometer, BigBite, have been examined. The most consistent and stable results were obtained by using a method based on singular value…

Long-range active imaging has a variety of applications in remote sensing and target recognition. Single-photon LiDAR (light detection and ranging) offers single-photon sensitivity and picosecond timing resolution, which is desirable for…

Image and Video Processing · Electrical Eng. & Systems 2020-09-07 Zheng-Ping Li , Xin Huang , Yuan Cao , Bin Wang , Yu-Huai Li , Weijie Jin , Chao Yu , Jun Zhang , Qiang Zhang , Cheng-Zhi Peng , Feihu Xu , Jian-Wei Pan

On-line monitoring of beam quality for high brightness beams is only possible using non-invasive instruments. For matching measurements, very few such instruments are available. One candidate is a quadrupole pick-up. Therefore, a new type…

Accelerator Physics · Physics 2009-11-07 Andreas Jansson

A monolithic active pixel sensor based direct detector that is optimized for the primary beam energies in scanning electron microscopes is implemented for electron back-scattered diffraction (EBSD) applications. The high detection…

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon…

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm$^2$ sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a…

Electron beam ion traps (EBIT) are ideal tools for both production and study of highly charged ions (HCI). In order to reduce their construction, maintenance, and operation costs we have developed a novel, compact, room-temperature design,…

The measurement of transient optical fields has proven critical to understanding the dynamical mechanisms underlying ultrafast physical and chemical phenomena, and is key to realizing higher speeds in electronics and telecommunications.…

The mostly research fasten on high emission density of injector to study electron beam's brightness in LIA. Using the injector(2MeV) was built to research brightness of multi-pulsed high current(KA) electron beam, and researchs three…

Accelerator Physics · Physics 2015-10-22 Yuan Wang , XiaoGuo Jiang , Huang Zhang , GuoJun Yang , YiDing Li , Jin Li