Related papers: Improved Calibration of Instruments for Small Dire…

200 papers

We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the…

Instrumentation and Detectors · Physics 2018-11-26 Hansjörg Scherer , Dietmar Drung , Christian Krause , Martin Götz , Ulrich Becker

A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The…

Instrumentation and Detectors · Physics 2014-08-07 Hansjörg Scherer , Gerd-Dietmar Willenberg , Dietmar Drung , Martin Götz , Eckart Pesel

An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA…

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current…

Instrumentation and Detectors · Physics 2014-08-22 Dietmar Drung , Christian Krause , Ulrich Becker , Hansjörg Scherer , Franz Josef Ahlers

In this paper, we present a programmable Ultra Low DC Current Source (ULCS) developed at T\"UB\.ITAK UME. The output current range is from 1 fA up to 100 pA with 100 aA resolution and is directly traceable to DC voltage, capacitance and…

Instrumentation and Detectors · Physics 2019-07-23 Omer Erkan , Yakup Gulmez , Cem Hayirli , Gulay Gulmez , Enis Turhan

New technology, the ultrastable low-noise current amplifier and the electron pump, provide new methods for making traceable measurements of small DC electric currents. We review four traceability routes for small current measurements and…

Instrumentation and Detectors · Physics 2020-03-31 Stephen Giblin , Jordan Tompkins

An ultrastable low-noise current amplifier (ULCA) has been transferred between two laboratories, NPL and PTB, four times, with three of the transfers yielding a relative change in the trans-resistance gain of less than $2 \times 10^{-7}$.…

Instrumentation and Detectors · Physics 2019-03-08 Stephen Giblin , Dietmar Drung , Martin Goetz , Hansjoerg Scherer

Modern commercial direct-current current transformers (DCCT) can measure currents up to the kA range with accuracies better than 1E-5. We discuss here a DCCT calibration method and its implementation with commercial instruments typically…

Instrumentation and Detectors · Physics 2016-11-17 Luca Callegaro , Cristina Cassiago , Enrico Gasparotto

We describe a calibration setup for the transresistance of low-current amplifiers, based on the capacitance-charging method. The calibration can be performed in the current range of typical interest for electron counting experiments. The…

Instrumentation and Detectors · Physics 2016-10-18 Ilaria Finardi , Luca Callegaro

The capacitance-charging method is a well-established and handy technique for the generation of dc current in the 100 pA range or lower. The method involves a capacitance standard and a sampling voltmeter, highly stable devices easy to…

Instrumentation and Detectors · Physics 2013-12-09 Luca Callegaro , Pier Paolo Capra , Vincenzo D'Elia , Flavio Galliana

A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J.…

Instrumentation and Detectors · Physics 2021-08-11 Sophie Djordjevic , Ralf Behr , Dietmar Drung , Martin Götz , Wilfrid Poirier

We compared the performance of a commercial ammeter and a home-made integrating electrometer in reading ionisation chamber currents less than 100 pA. The integrating electrometer charges a capacitor with the unknown current and measures the…

Instrumentation and Detectors · Physics 2019-03-08 Stephen P. Giblin , Giuseppe Lorusso

A low noise constant current source used for measuring the $1/f$ noise in disordered systems in ohmic as well as non-ohmic regime is described. The source can supply low noise constant current starting from as low as 1 $\mu$A to a few tens…

Disordered Systems and Neural Networks · Physics 2015-05-20 D. Talukdar , R. K. Chakraborty , Suvendu Bose , K. K. Bardhan

We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the…

Atomic Physics · Physics 2022-07-25 M. S. Mrozowski , I. C. Chalmers , S. J. Ingleby , P. F. Griffin , E. Riis

We broach a seldom-discussed topic in precision metrology; how subtle errors in calibration processes are discovered and remedied. We examine a case study at the National Physical Laboratory (NPL), UK, involving the calibration of DC…

Instrumentation and Detectors · Physics 2025-12-03 Stephen Giblin

This manual is intended to help ALMA and other interferometer users improve images by recognising limitations and how to overcome them and deciding when and how to use self-calibration. The images provided by the ALMA Science Archive are…

Instrumentation and Methods for Astrophysics · Physics 2022-07-13 A. M. S. Richards , E. Moravec , S. Etoka , E. B. Fomalont , A. F. Pérez-Sánchez , M. C. Toribio , R. A. Laing

We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging…

Other Condensed Matter · Physics 2016-11-17 Hansjörg Scherer , Gerd-Dietmar Willenberg , Dietmar Drung , Martin Götz , Eckart Pesel

Atomic force microscopy (AFM) is an analytical surface characterization tool which can reveal a sample's topography with high spatial resolution while simultaneously probing tip-sample interactions. Local measurement of chemical properties…

Applied Physics · Physics 2018-09-06 Omur E. Dagdeviren , Yoichi Miyahara , Aaron Mascaro , Peter Grutter

Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the…

Instrumentation and Detectors · Physics 2025-03-06 Shunyi Liang , Juncheng Liang , Kezhu Song , Yijie Jiang , Zhijie Yang

Characterizing the variability of the extragalactic sources used for calibration in the Atacama Large Millimeter/Sub-millimeter Array (ALMA) is key to assess the flux scale uncertainty of science observations. To this end, we model the…

Instrumentation and Methods for Astrophysics · Physics 2019-08-12 A. E. Guzmán , C. Verdugo , H. Nagai , Y. Contreras , G. Marinello , R. Kneissl , K. Nakanishi , J. Ueda