English
Related papers

Related papers: A passive THz video camera based on lumped element…

200 papers

We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor…

Thermal Kinetic Inductance Detectors (TKIDs) inherently combine the phonon-limited noise performance of traditional bolometers with the array scalability and responsivity of superconducting kinetic inductance detectors. Using a…

Applied Physics · Physics 2026-03-16 T. Jabbari , A. Hawkins , A. Wandui , C. Frez , J. Greenfield , C. Roberson , M. J. Lee , P. Mauskopf , D. Cunnane

The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for…

Instrumentation and Detectors · Physics 2016-01-20 A. Giachero , P. K. Day , P. Falferi , M. Faverzani , E. Ferri , C. Giordano , M. Maino , B. Margesin , R. Mezzena , R. Nizzolo , A. Nucciotti , A. Puiu , L. Zanetti

We have developed two arrays of lumped element kinetic inductance detectors working in the D-band, and optimised for the low radiative background conditions of a satellite mission aiming at precision measurements of the Cosmic Microwave…

From biology and astronomy to quantum optics, there is a critical need for high frame rate, high quantum efficiency imaging. In practice, most cameras only satisfy one of these requirements. Here we introduce interlaced fast kinetics…

Atomic Physics · Physics 2025-05-21 Bowen Li , Lukas Palm , Marius Jürgensen , Yiming Cady Feng , Markus Greiner , Jon Simon

We present the results of a feasibility study, which examined deployment of a ground-based millimeter-wave polarimeter, tailored for observing the cosmic microwave background (CMB), to Isi Station in Greenland. The instrument for this study…

Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct…

We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single…

Instrumentation and Detectors · Physics 2016-10-14 P. Szypryt , B. A. Mazin , G. Ulbricht , B. Bumble , S. R. Meeker , C. Bockstiegel , A. B. Walter

We describe the design, fabrication, and operation of an infrared camera which is in use at the 30-inch telescope of the Leuschner Observatory. The camera is based on a Rockwell PICNIC 256 x 256 pixel HgCdTe array, which is sensitive from…

Astrophysics · Physics 2009-11-06 James R. Graham , Richard R. Treffers

We have fabricated 2024 pixel microwave kinetic inductance detector (MKID) arrays in the ultraviolet/optical/near-IR (UVOIR) regime that are currently in use in astronomical instruments. In order to make MKIDs desirable for novel…

Instrumentation and Detectors · Physics 2017-11-23 P. Szypryt , B. A. Mazin , B. Bumble , H. G. Leduc , L. Baker

We present our current progress on the design and test of Ti/TiN Multilayer for use in Kinetic Inductance Detectors (KIDs). Sensors based on sub-stoichiometric TiN film are commonly used in several applications. However, it is difficult to…

The near-earth object camera (NEOCam) is a proposed infrared space mission designed to discover and characterize most of the potentially hazardous asteroids larger than 140 m in diameter that orbit near the Earth. NASA has funded technology…

The non-homogeneity in the critical temperature $T_{c}$ of an Microwave Kinetic Inductance Detector (MKID) could be caused by non-uniformity in the deposition process of the thin superconducting film. This produces low percent yield and…

Instrumentation and Detectors · Physics 2019-11-18 Israel Hernandez , Martin Makler , Juan Estrada , Clecio R. Bom , Donna Kubik , Julian Amette , Jorge Montes , Andrew Leptop

We present measurements and simulations of the polarization purity of leaky lens-antenna coupled microwave Kinetic Inductance Detectors (KIDs) at 1.5 THz. We find the integrated cross-polarization level to be at -21.5 dB for 1 f\#$\lambda$…

We present a method of spatially mapping microwave kinetic inductance detector (MKID) arrays, in a dark setup. MKIDs are superconducting natively multiplexed resonators which enable kilopixel arrays, such as for the proposed Probe…

Instrumentation and Methods for Astrophysics · Physics 2026-04-15 Chris Albert , Ritoban Basu Thakur , Farzad Faramarzi , Byeong Ho Eom , Sumit Dahal , Andrew Bear , Reinier Janssen , Henry LeDuc , Thomas Stevenson , Peter Day

A prototype of digital frequency multiplexing electronics allowing the real time monitoring of kinetic inductance detector (KIDs) arrays for mm-wave astronomy has been developed. It requires only 2 coaxial cables for instrumenting a large…

Instrumentation and Methods for Astrophysics · Physics 2015-03-18 O. Bourrion , A. Bideaud , A. Benoit , A. Cruciani , J. F. Macias-Perez , A. Monfardini , M. Roesch , L. Swenson , C. Vescovi

We describe the development, operation, and application of the 4D Camera -- a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at approximately 480…

The Stratospheric Kinetic Inductance Polarimeter (SKIP) is a proposed balloon-borne experiment designed to study the cosmic microwave background, the cosmic infrared background and Galactic dust emission by observing 1133 square degrees of…

Photodetectors based on nano-structured superconducting thin films are currently some of the most sensitive quantum sensors and are key enabling technologies in such broad areas as quantum information, quantum computation and…

Microwave Kinetic Inductance Detectors (MKIDs) provide highly multiplexed arrays of detectors that can be configured to operate from the sub-millimeter to the X-ray regime. We have examined two tungsten silicide alloys (W5Si3 and WSi2),…