English
Related papers

Related papers: An InGrid based Low Energy X-ray Detector

200 papers

Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background…

Instrumentation and Detectors · Physics 2016-06-22 F. J. Iguaz , J. G. Garza , F. Aznar , J. F. Castel , S. Cebrian , T. Dafni , J. A. Garcia , I. G. Irastorza , A. Lagraba , G. Luzon , A. Peiro

Emulsion detectors feature a very high position resolution and consequently represent an ideal device when particle detection is required at the micrometric scale. This is the case of quantum interferometry studies with antimatter, where…

High Energy Physics - Experiment · Physics 2016-08-03 S. Aghion , A. Ariga , T. Ariga , M. Bollani , E. Dei Cas , A. Ereditato , C. Evans , R. Ferragut , M. Giammarchi , C. Pistillo , M. Romé , S. Sala , P. Scampoli

We describe a concept for a NASA SMEX Mission in which Gas Electron Multiplier (GEM) detectors, developed at CERN, are adapted for use in X-ray astronomy. These detectors can be used to obtain moderately large detector area and…

X-rays have widespread applications in science and industry, but developing a simple, compact, and high-quality X-ray source remains a challenge. Our collaboration has explored the possible use of channeling radiation driven by a 50 MeV…

Accelerator Physics · Physics 2016-12-23 A. Halavanau , D. Mihalcea , D. Broemmelsiek , D. Edstrom , T. Sen , A. Romanov , J. Ruan , V. Shiltsev , P. Kobak , W. Rush , J. Hyun

The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…

Instrumentation and Detectors · Physics 2015-10-28 S. R. Mirfayzi

An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray…

We fabricated a superconducting single X-ray photon detector based on W0.8Si0.2, and we characterized its basic detection performance for keV-photons at different temperatures. The detector has a critical temperature of 4.97 K, and it is…

Instrumentation and Detectors · Physics 2016-10-31 X. Zhang , Q. Wang , A. Schilling

A novel graphene-optimized silicon carbide PIN detector was fabricated. Its electrical properties, charge collection performance and signal rise time were evaluated under non-irradiated conditions and under X-ray irradiation with an energy…

Instrumentation and Detectors · Physics 2026-05-07 Yingjie Huang , Congcong Wang , Jingxuan He , Yi Zhan , Zhenyu Jiang , Xiyuan Zhang , Xin Shi

An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose first-stage JFET has been cooled. The operating temperature of the JFET has…

High Energy Physics - Experiment · Physics 2009-10-28 Yoshizumi Inoue , Shigetaka Moriyama , Hideyuki Hara , Makoto Minowa , Fumio Shimokoshi

In this paper (Paper II) we complete our discussion on the results of a comprehensive GEANT simulation of the scientific performance of the AGILE Gamma-Ray Imaging Detector (GRID), operating in the 30 MeV - 50 GeV energy range in an…

Astrophysics · Physics 2015-06-24 Veronica Cocco , Francesco Longo , Marco Tavani

We present an X-ray spectrum of the diffuse X-ray background (DXRB) between 1.5 and 120 keV, as measured with the Low-Energy Detector (LE) and the High-Energy Detector (HE) aboard the Insight-HXMT satellite, based on 'blank-sky'…

High Energy Astrophysical Phenomena · Physics 2023-06-21 Rui Huang , Wei Cui , Jin-Yuan Liao , Shuo Zhang , Si-Fan Wang , Jing Jin , Xue Feng Lu , Cheng-Cheng Guo , Yuan You , Gang Li , Juan Zhang

Active Pixel Sensor (APS) technology has shown promise for next-generation vertex detectors. This paper discusses the design and testing of two generations of APS chips. Both are arrays of 128 by 128 pixels, each 20 by 20 micro-m. Each…

Nuclear Experiment · Physics 2011-07-19 H. S. Matis , F. Bieser , S. Kleinfelder , G. Rai , F. Retiere , H. G. Ritter , K. Singh , S. E. Wurzel , H. Wieman , E. Yamamoto

We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to…

Astrophysics · Physics 2009-11-07 P. F. Bloser , F. Schopper , R. Andritschke , G. Kanbach , A. Zoglauer , P. Lechner

In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting…

Instrumentation and Detectors · Physics 2019-08-01 Geovane G. A. de Souza , Hugo Natal da Luz

The use of low-temperature detectors, such as cryogenic calorimeters, has pioneered the recent advancements in low-energy rare event searches. These detectors provide a low-noise environment essential for the direct detection of dark matter…

Instrumentation and Detectors · Physics 2026-02-25 Giorgio Del Castello

This paper describes the development of a novel medical Xray imaging system adapted to the needs and constraints of low and middle income countries. The developed system is based on an indirect conversion chain: a scintillator plate…

A hybrid pixel detector based on the concept of simultaneous charge integration and photon counting will be presented. The second generation of a counting and integrating X-ray prototype CMOS chip (CIX) has been operated with different…

Instrumentation and Detectors · Physics 2009-11-13 H. Krüger , J. Fink , E. Kraft , N. Wermes , P. Fischer , I. Peric , C. Herrmann , M. Overdick , W. Rütten

Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to 600…

Astrophysics · Physics 2009-11-10 H. Krawczynski , I. Jung , J. Perkins , A. Burger , M. Groza

The TREX-DM detector, a low background chamber with microbulk Micromegas readout, was commissioned in the underground laboratory of Canfranc (LSC) in 2018. Since then, data taking campaigns have been carried out with Argon and Neon…

For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good…