English

Characterization of a triple-GEM position sensitive detector for X-ray fluorescence imaging

Instrumentation and Detectors 2019-08-01 v1

Abstract

In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting the strips, we are able to reconstruct the radiation interaction points by resistive charge division. The detector achieved gains above 10410^4, energy resolution of 15.28% (FWHM) for 5.9keV X-rays, and position resolution of 1.2mm, while operating in Ar/CO2_2(90/10) at atmospheric pressure.

Keywords

Cite

@article{arxiv.1904.08466,
  title  = {Characterization of a triple-GEM position sensitive detector for X-ray fluorescence imaging},
  author = {Geovane G. A. de Souza and Hugo Natal da Luz},
  journal= {arXiv preprint arXiv:1904.08466},
  year   = {2019}
}

Comments

10 pages, 12 figures, submitted to the Proceedings of the European Conference on X-Ray Spectrometry (2018)