Related papers: An InGrid based Low Energy X-ray Detector
The NeXT mission has been proposed to study high-energy non-thermal phenomena in the universe. The high-energy response of the super mirror will enable us to perform the first sensitive imaging observations up to 80 keV. The focal plane…
An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our…
The response of Low Gain Avalanche Diodes (LGADs), a type of thin silicon detector with internal gain, to X-rays of energies between 6-16~keV was characterized at the Stanford Synchrotron Radiation Lightsource (SSRL). The utilized beamline…
For the ATLAS Pixel Detector fast readout electronics has been successfully developed and tested. Main attention was given to the ability to detect small charges in the order of 5,000 electrons within 25 ns in the harsh radiation…
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and…
We present the operation with moderate radiation shield in a surface laboratory of BULLKID (BULky and Low-threshold Kinetic Inductance Detector), a cryogenic detector for searches of light Dark Matter or Coherent Elastic Neutrino-Nucleus…
Very high energy gamma-ray data obtained by CAT and HEGRA from active galactic nucleus Mkn 501 are used to constrain the cosmic Mid-Infrared background. While the entire infrared and submillimeter spectrum shape based on models has been…
The Speedster-EXD is a new 64x64 pixel, 40 $\mu$m pixel pitch, 100 $\mu$m depletion depth hybrid CMOS X-ray detector (HCD) with the capability of reading out only those pixels containing event charge, thus enabling fast effective frame…
The Gamma-ray Large Area Space Telescope (GLAST) is now being designed by a number of collaborating institutions. It will study the cosmic gamma radiation from 20 MeV to 300 GeV with high precision and sensitivity, greatly expanding on the…
The High Energy Cosmic-Radiation Detection (HERD) facility has been proposed as a leading experiment on China's Space Station (CSS). Scheduled for installation around 2027, HERD is expected to operate for at least a decade. The main…
We report on the results of a new, sealed, Gas Pixel Detector. The very compact design and the absence of the gas flow system, make this detector substantially ready for use as focal plane detector for future X-ray space telescopes. The…
A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron…
The LUXE experiment aims at studying high-field QED in electron-laser and photon-laser interactions, with the 16.5 GeV electron beam of the European XFEL and a laser beam with power of up to 350 TW. The experiment will measure the spectra…
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density…
The advent of back-illuminated complementary metal-oxide-semiconductor (CMOS) sensors and their well-known advantages over charge-coupled devices (CCDs) make them an attractive technology for future X-ray missions. However, numerous…
Silicon-based tracking detectors have been used in several important applications, such as in cancer therapy using particle beams, and for the discovery of new elementary particles at the Large Hadron Collider at CERN. III-V semiconductor…
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…
We reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 $\times$ 7.5 $\times$ 15 cm), modular X-ray calorimeter made of…
The CERN proposed $e^+e^-$ Future Circular Collider (FCC-ee) is an electroweak, flavour, Higgs and top factory with unprecedented luminosities. Many measurements at the FCC-ee will rely on precisely determining the particle production…
Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An…