English
Related papers

Related papers: In-situ Piezoresponse Force Microscopy Cantilever …

200 papers

We propose a two-frequency driving scheme in dynamic atomic force microscopy that maximizes the interaction time between tip and sample. Using a stochastic description of the cantilever dynamics, we predict large classical squeezing and a…

Mesoscale and Nanoscale Physics · Physics 2022-01-20 Karl-Peter Marzlin , Bryan Canam , Nisha Rani Agarwal

While piezoelectrics and ferroelectrics are playing a key role in many everyday applications, there are still a number of open questions related to the physics of those materials. In order to foster the understanding of piezoelectrics and…

Materials Science · Physics 2017-12-01 Andres Gomez , Marti Gich , Adrien Carretero-Genevrier , Teresa Puig , Xavier Obradors

This Paper deals design and simulation of electrostatically actuated clamped clamped beam and cantilever beam using finite element analysis method (FEM). A detailed study and performance analysis for various bias voltages is provided in…

Computational Physics · Physics 2010-02-12 D. Mohana Geetha , M. Madheswaran

In atomic force microscopy (AFM), the exchange and alignment of the AFM cantilever with respect to the optical beam and position-sensitive detector (PSD) are often performed manually. This process is tedious and time-consuming and sometimes…

Instrumentation and Detectors · Physics 2016-10-12 Tom Bijnagte , Geerten Kramer , Lukas Kramer , Bert Dekker , Rodolf Herfst , Hamed Sadeghian

We perform simulations and experiments on an oscillating atomic force microscope cantilever approaching a surface, where the intermodulation response of the cantilever driven with two pure harmonic tones is investigated. In the simulations,…

Mesoscale and Nanoscale Physics · Physics 2013-02-25 Daniel Platz , Daniel Forchheimer , Erik A. Tholén , Carsten Hutter , David B. Haviland

Given that a ferroelectric domain is generally a three dimensional entity, the determination of its area as well as its depth is mandatory for full characterization. Piezoresponse force microscopy (PFM) is known for its ability to map the…

Intrinsic domain wall width is a fundamental parameter that reflects bulk ferroelectric properties and governs the performance of ferroelectric memory devices. We present closed-form analytical expressions for vertical and lateral…

The thermodynamics and kinetics of tip-induced polarization switching in Piezoresponse Force Microscopy in the presence of surface charge defects is studied using the combination of analytical and numerical techniques. The signature of the…

We describe a method for feedback-regulation of a microcantilever's response using optical radiation pressure. One laser measures the position of the cantilever and another laser applies a force that is a phase-shifted function of that…

Other Condensed Matter · Physics 2009-11-11 D. M. Weld , A. Kapitulnik

This work is a theoretical investigation of the stability of the non-linear behavior of an oscillating tip-cantilever system used in dynamic force microscopy. Stability criterions are derived that may help to a better understanding of the…

Atomic and Molecular Clusters · Physics 2016-08-16 Laurent Nony , Rodolphe Boisgard , Jean-Pierre Aimé

We experimentally surpass the 3dB limit to steady state parametric squeezing of a mechanical oscillator. The localization of a AFM cantilever, achieved by optimal estimation, is enhanced by up to 6.2 dB in one position quadrature when a…

Mesoscale and Nanoscale Physics · Physics 2013-05-08 Alex Szorkovszky , George A. Brawley , Andrew C. Doherty , Warwick P. Bowen

Euler-Bernoulli beam theory is widely used to successfully predict the linear dynamics of micro- and nano-cantilever beams. However, its capacity to characterize the nonlinear dynamics of these devices has not yet been rigorously assessed,…

Mesoscale and Nanoscale Physics · Physics 2015-06-12 L. G. Villanueva , R. B. Karabalin , M. H. Matheny , D. Chi , J. E. Sader , M. L. Roukes

We consider an oscillator model to describe qualitatively friction force for an atomic force mi-croscope (AFM) tip driven on a surface described by periodic potential. It is shown that average value of the friction force could be controlled…

Pattern Formation and Solitons · Physics 2020-10-06 E. V. Kazantseva , Y. Braiman , J. Barhen

We propose a new method to investigate interactions involved in atomic force microscopy (AFM). It is a dynamical method relying on the growth of oscillations via parametric resonance. With this method the second and third derivatives of the…

Materials Science · Physics 2007-05-23 Franz-Josef Elmer

Measurements with an atomic force microscope (AFM) offer a direct way to probe elastic properties of lipid bilayer membranes locally: provided the underlying stress-strain relation is known, material parameters such as surface tension or…

Soft Condensed Matter · Physics 2007-05-23 Davood Norouzi , Martin Michael Mueller , Markus Deserno

While the fundamental limit on the resolution achieved in an atomic force microscope (AFM) is clearly related to the tip radius, the fact that the tip can creep and/or wear during an experiment is often ignored. This is mainly due to the…

Mesoscale and Nanoscale Physics · Physics 2015-06-12 Sergio Santos , Victor Barcons , Josep Font , Neil H Thomson

Phase Resolved Optical Emission Spectroscopy (PROES) measurements combined with 1d3v Particle-in-Cell/Monte Carlo Collision (PIC/MCC) simulations are performed to investigate the excitation dynamics in low-pressure capacitively coupled…

Plasma Physics · Physics 2023-07-21 Aranka Derzsi , Mate Vass , Ranna Masheyeva , Benedek Horvath , Zoltan Donko , Peter Hartmann

The electric forces acting on an atomic force microscope tip in solution have been measured using a microelectrochemical cell formed by two periodically biased electrodes. The forces were measured as a function of lift height and bias…

Materials Science · Physics 2008-03-13 B. J. Rodriguez , S. Jesse , K. Seal , A. P. Baddorf , S. V. Kalinin

Piezoresistive strain gauges allow for electronic readout of mechanical deformations with high fidelity. As piezoresistive strain gauges are aggressively being scaled down for applications in nanotechnology, it has become critical to…

Applied Physics · Physics 2021-09-21 C. Ti , A. B. Ari , M. C. Karakan , C. Yanik , I. I. Kaya , M. S. Hanay , O. Svitelskiy , M. Gonzalez , H. Seren , K. L. Ekinci

Direct time-varying tip-sample force measurements by torsional harmonic cantilevers facilitate detailed investigations of the cantilever dynamics in tapping-mode atomic force microscopy. Here we report experimental evidence that the…

Instrumentation and Detectors · Physics 2008-11-26 Ozgur Sahin