English
Related papers

Related papers: A GEANT4 Simulation Studyof BESIII endcap TOF Upgr…

200 papers

A GEANT4-based simulation is developed for the endcap time of flight (ETOF) upgrade based on multi-gap resistive plate chambers (MRPC) for the BESIII experiment. The MRPC prototype and the simulation method are described. Using a full…

Instrumentation and Detectors · Physics 2016-11-03 F. F. An , S. S. Sun , H. M. Liu , W. G. Li , Z. Y. Deng , H. H. Liu , J. Y. Liu , R. X. Yang

The Beijing Spectrometer III (BESIII) endcap Time-Of-Filght (ETOF) was proposed to upgrade with Multigap Resistive Plate Chamber (MRPC) technology to substitute the current ETOF of scintillator+PMT for extending time resolutin better than…

The upgrade of the current BESIII Endcap TOF (ETOF) is carried out with the Multi-gap Resistive Plate Chamber (MRPC) technology. The installation of the new ETOF has been finished in October 2015. The first results of the MRPCs…

The prototype of time digitizing system for the upgrade of BESIII endcap TOF (ETOF) is introduced in this paper. The ETOF readout electronics has a formation of distributed architecture that hit signal from multi-gap resistive plate chamber…

Instrumentation and Detectors · Physics 2013-06-04 Cao Ping , Sun Wei-Jia , Ji Xiao-Lu , Fan Huan-Huan , Wang Si-Yu , Liu Shu-Bin , An Qi

The results of a full simulation of an endcap Time-of-Flight detector upgrade based on multigap resistive plate chambers for the BESIII experiment are presented. The simulation and reconstruction software is based on Geant4 and has been…

Instrumentation and Detectors · Physics 2014-11-11 M. Ullrich , W. Kühn , Y. Liang , B. Spruck , M. Werner

It is proposed to upgrade the endcap time-of-flight (ETOF) of the Beijing Spectrometer III (BESIII) with multi-gap resistive plate chamber (MRPC), aiming at overall time resolution about 80 ps. After the entire electronics system is ready,…

Instrumentation and Detectors · Physics 2016-03-16 Wang Xiaozhuang , Dai Hongliang , Wu Zhi , Heng Yuekun , Zhang Jie , Cao Ping , Ji Xiaolu , Li Cheng , Sun Weijia , Wang Siyu , Wang Yun

In order to further enhance the particle identification capability of the Beijing Spectrometer (BESIII), it is proposed to upgrade the current end-cap time-of-flight (eTOF) detector with multi-gap resistive plate chamber (MRPC). The…

Instrumentation and Detectors · Physics 2014-12-16 S. Yang , Y. J. Sun , C. Li , Y. K. Heng , S. Qian , H. F. Chen , T. X. Chen , H. L. Dai , H. H. Fan , S. B. Liu , S. D. Liu , X. S. Jiang , M. Shao , Z. B. Tang , H. Zhang , Z. G. Zhao

The Time-Of-Flight system consisting of plastic scintillation counters plays an important role for particle identification in the BESIII experiment at the BEPCII double ring $e^+e^-$ collider. Degradation of the detection efficiency of the…

Instrumentation and Detectors · Physics 2018-03-14 Huan-Huan Liu , Sheng-Sen Sun , Shuang-Shi Fang , Zhi Wu , Hong-Liang Dai , Yue-Kun Heng , Ming Zhou , Zi-Yan Deng , Huai-Min Liu

The STAR experiment at RHIC at Brookhaven National Laboratory completed the installation of an endcap time-of-flight subsystem (eTOF) in February 2019. The eTOF subsystem provided essential mid-rapidity particle identification (PID) for the…

Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive…

Instrumentation and Detectors · Physics 2018-07-02 Rajesh Ganai , Shaifali Mehta , Mehulkumar Shiroya , Mitali Mondal , Zubayer Ahammed , Subhasis Chattopadhyay

The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…

Instrumentation and Detectors · Physics 2019-07-23 M. Nizam , B. Satyanarayana , R. R. Shinde , G. Majumder

The low cost and high resolution gas-based Multi-gap Resistive Plate Chamber (MRPC) opens a new possibility to find an efficient alternative detector for Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2011-06-30 A. Banerjee , S. Chattopadhyay

The Compressed Baryonic Matter (CBM) experiment is one of the major scientific spectrometers of the future Facility for Antiproton and Ion Research (FAIR) in Darmstadt. As one of the core sub-systems in CBM experiment for charged hadron…

Instrumentation and Detectors · Physics 2023-09-01 K. Wang , J. Zhou , X. Wang , X. Li , D. Hu , Y. Sun

T0 detector, based on Multi-gap Resistive Plate Chambers (MRPC) technology, is one of the key components in the External Target Experiment. Through precision measurements of the MRPC signals, timing of the beam impact on target can be…

Instrumentation and Detectors · Physics 2019-09-25 Peipei Deng , Lei Zhao , Jiaming Lu , Pinzheng Xia , Jinxin Liu , Min Li , Shubin Liu , Qi An

A new fanning topology is proposed to precisely fan out fast control signals in the Beijing Spectrometer (BES III) end-cap time-of-flight (ETOF) electronics. However, uncertainty in transfer latency is introduced by the new fanning channel,…

Instrumentation and Detectors · Physics 2016-05-31 Yun Wang , Ping Cao , Shubin Liu , Qi An

Triple-GEM detectors for the GE2/1 and ME0 stations of the endcap muon system for the Phase-2 upgrade of the CMS Experiment have been operated in a test beam to measure their efficiency and spatial resolution, together with a high spatial…

Instrumentation and Detectors · Physics 2022-11-23 Antonello Pellecchia , Piet Verwilligen , Anna Stamerra

We present the design and characterization of the first full chain precision timing prototype ASIC, named ETL Readout Chip version 1 (ETROC1) for the CMS MTD endcap timing layer (ETL) upgrade. The ETL utilizes Low Gain Avalanche Diode…

We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in…

The use of Time Of Flight (TOF) in Positron Emission Tomography (PET) is expected to reduce noise on images, thanks to the additional information. In clinical routine, a common reconstruction approach is the use of maximum likelihood…

Medical Physics · Physics 2019-10-16 Luca Presotto , Elisabetta De Bernardi , Valentino Bettinardi

A linear Breit-Wheeler module for the code Geant4 has been developed. This allows signal-to-noise ratio calculations of linear Breit-Wheeler detection experiments to be performed within a single framework. The interaction between two photon…

Plasma Physics · Physics 2023-05-31 R. A. Watt , S. J. Rose , B. Kettle , S. P. D. Mangles
‹ Prev 1 2 3 10 Next ›