English

Fast Control Latency Uncertainty Elimination for the BESIII ETOF Upgrade

Instrumentation and Detectors 2016-05-31 v5 High Energy Physics - Experiment

Abstract

A new fanning topology is proposed to precisely fan out fast control signals in the Beijing Spectrometer (BES III) end-cap time-of-flight (ETOF) electronics. However, uncertainty in transfer latency is introduced by the new fanning channel, which will degrade the precision of fast control. In this paper, latency uncertainty elimination for the BESIII ETOF upgrade is introduced. The latency uncertainty is determined by a Time-Digital-Converter (TDC) embedded in a Field-Programmable Gate Array (FPGA) and is eliminated by re-capturing at synchronous and determinate time. Compared with the existing method of Barrel-cap TOF (BTOF), it has advantages of flexible structure, easy calibration and good adaptability. Field tests on the BES III ETOF system show that this method effectively eliminates transfer latency uncertainty.

Keywords

Cite

@article{arxiv.1603.00015,
  title  = {Fast Control Latency Uncertainty Elimination for the BESIII ETOF Upgrade},
  author = {Yun Wang and Ping Cao and Shubin Liu and Qi An},
  journal= {arXiv preprint arXiv:1603.00015},
  year   = {2016}
}

Comments

6pages, 12 figures, This paper is to be published in Chinese Physics C