English
Related papers

Related papers: Test beam studies for a highly granular GRPC Semi-…

200 papers

The SiPM-on-Tile technology for highly granular calorimeters, where small plastic scintillator tiles are directly read out with SiPMs, has been developed for the CALICE Analog Hadron Calorimeter, and has been adopted for parts of the…

Instrumentation and Detectors · Physics 2025-09-04 Fabian Hummer , Lorenz Emberger , Frank Simon

In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout…

X-ray calorimetric sample platforms combining specific heat and synchrotron x-ray measurements provide a powerful means to investigate fundamental material properties. Calorimeter cell designs featuring a compact heater and thermometer…

Instrumentation and Detectors · Physics 2026-02-02 U. Patel , H. Zheng , J. L. McChesney , U. Welp , Z. Islam , A. Miceli

The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of…

Instrumentation and Detectors · Physics 2016-09-21 F. Lagarde , M. Gouzevitch , I. Laktineh , V. Buridon , X. Chen , C. Combaret , A. Eynard , L. Germani , G. Grenier , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeuraa , Y. Wang , A. Gongab , N. Moreau , C. de la Taille , F. Dulucqac , A. Cimmino , S. Crucy , A. Fagot , M. Gul , A. A. O. Rios , M. Tytgat , N. Zaganidisb , S. Aly , Y. Assran , A. Radi , A. Sayedc , G. Singhd , M. Abbrescia , G. Iaselli , M. Maggi , G. Pugliese , P. Verwilligene , W. Van Doninck , S. Colafranceschi , A. Sharmag , L. Benussi , S. Bianco , D. Piccolo , F. Primaverah , V. Bhatnagar , R. Kumari , A. Mehta , J. Singhi , A. Ahmad , W. Ahmed , H. M. I. Asghar , I. M. Awan , R. Hoorani , S. Muhammad , H. Shahzad , M. A. Shah , S. W. Cho , S. Y. Choi , B. Hong , M. H. Kang , K. S. Lee , J. H. Lim , S. K. Parkk , M. S. Kiml , S. Carpinteyro Bernardino , I. Pedraza , C. Uribe Estradam , S. Carrillo Moreno , F. Vazquez Valencian , L. M. Panto , S. Buontempo , N. Cavallo , M. Esposito , F. Fabozzi , G. Lanza , I. Orso , L. Lista , S. Meola , M. Merola , P. Paolucci , F. Thyssen , A. Braghieri , A. Magnani , P. Montagna , C. Riccardi , P. Salvini , I. Vai , P. Vituloq , Y. Ban , S. J. Qianr , M. Choi , Y. Choi , J. Goh , D. Kimt , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , S. Stoykova , G. Sultanov , M. Vutovau , A. Dimitrov , L. Litov , B. Pavlov , P. Petkovv , I. Bagaturia , D. Lomidzew , C. Avila , A. Cabrera , J. C. Sanabria , I. Crottyy , J. Vaitkusz

This communication describes test beam results, focusing on detection efficiency and timing precision, of common float glass timing Resistive Plate Chambers (tRPCs) exposed to a $2.7$~GeV proton beam and operated at above ambient…

Instrumentation and Detectors · Physics 2022-11-23 A. Blanco , P. Fonte , L. Lopes , J. Saraiva

A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination…

Instrumentation and Detectors · Physics 2019-08-14 T. Peitzmann

This paper reports on the performance of Resistive Plate Chambers (RPCs) as function of the gas flow rate through the chambers and of environmental conditions, such as atmospheric pressure, ambient temperature and air humidity. The chambers…

Instrumentation and Detectors · Physics 2010-05-07 Burak Bilki , John Butler , Ed May , Georgios Mavromanolakis , Edwin Norbeck , Jose Repond , David Underwood , Lei Xia , Qingmin Zhang

The CALICE collaboration has constructed highly granular hadronic and electromagnetic calorimeter prototypes to evaluate technologies for the use in detector systems at a future Linear Collider. The hadron calorimeter uses 7608 small…

Instrumentation and Detectors · Physics 2010-06-21 Katja Seidel

Keeping in mind the requirements of high rate capable, cost effective, large area detectors to be used in future high energy physics experiments, commercially available bakelite plates having moderate bulk resistivity are used to build an…

Instrumentation and Detectors · Physics 2024-01-25 Arindam Sen , Sayak Chatterjee , Shreya Roy , Saikat Biswas , Supriya Das

Hybrid ECAL is a cost-conscious option of electromagnetic calorimeter (ECAL) for particle flow calorimetry to be used in a detector of International Linear Collider (ILC). It is a combination of silicon-tungsten ECAL, which realizes high…

Instrumentation and Detectors · Physics 2015-03-31 T. Suehara , H. Hirai , H. Sumida , H. Ueno , Y. Sudo , T. Yoshioka , K. Kawagoe

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high…

Instrumentation and Detectors · Physics 2009-09-29 CALICE Collaboration , J. Repond , J. Yu , C. M. Hawkes , Y. Mikami , O. Miller , N. K. Watson , J. A. Wilson , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , F. Badaud , D. Boumediene , C. Carloganu , R. Cornat , P. Gay , Ph. Gris , S. Manen , F. Morisseau , L. Royer , G. C. Blazey , D. Chakraborty , A. Dyshkant , K. Francis , D. Hedin , G. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , E. Garutti , V. Korbel , F. Sefkow , M. Groll , G. Kim , D-W. Kim , K. Lee , S. Lee , K. Kawagoe , Y. Tamura , D. A. Bowerman , P. D. Dauncey , A. -M. Magnan , C. Noronha , H. Yilmaz , O. Zorba , V. Bartsch , J. M. Butterworth , M. Postranecky , M. Warren , M. Wing , M. Faucci Giannelli , M. G. Green , F. Salvatore , T. Wu , D. Bailey , R. J. Barlow , M. Kelly , S. Snow , R. J. Thompson , M. Danilov , V. Kochetkov , N. Baranova , P. Ermolov , D. Karmanov , M. Korolev , M. Merkin , A. Voronin , B. Bouquet , S. Callier , F. Dulucq , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , M. Ruan , N. Seguin-Moreau , F. Wicek , Z. Zhang , M. Anduze , V. Boudry , J-C. Brient , C. Clerc , G. Gaycken , C. Jauffret , A. Karar , P. Mora de Freitas , G. Musat , M. Reinhard , A. Rouge , A. L. Sanchez , J-Ch. Vanel , H. Videau , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , Yu. Arestov , A. Baird , R. N. Halsall , S. W. Nam , I. H. Park , J. Yang

The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section…

Instrumentation and Detectors · Physics 2022-05-25 B. Acar , G. Adamov , C. Adloff , S. Afanasiev , N. Akchurin , B. Akgün , F. Alam Khan , M. Alhusseini , J. Alison , A. Alpana , G. Altopp , M. Alyari , S. An , S. Anagul , I. Andreev , P. Aspell , I. O. Atakisi , O. Bach , A. Baden , G. Bakas , A. Bakshi , S. Bannerjee , P. Bargassa , D. Barney , F. Beaudette , F. Beaujean , E. Becheva , A. Becker , P. Behera , A. Belloni , T. Bergauer , M. Besancon , S. Bhattacharya , D. Bhowmik , B. Bilki , P. Bloch , A. Bodek , M. Bonanomi , A. Bonnemaison , S. Bonomally , J. Borg , F. Bouyjou , N. Bower , D. Braga , J. Brashear , E. Brondolin , P. Bryant , A. Buchot Perraguin , J. Bueghly , B. Burkle , A. Butler-Nalin , O. Bychkova , S. Callier , D. Calvet , X. Cao , A. Cappati , B. Caraway , S. Caregari , A. Cauchois , L. Ceard , Y. C. Cekmecelioglu , S. Cerci , G. Cerminara , M. Chadeeva , N. Charitonidis , R. Chatterjee , Y. M. Chen , Z. Chen , H. J. Cheng , K. y. Cheng , S. Chernichenko , H. Cheung , C. H. Chien , S. Choudhury , D. Čoko , G. Collura , F. Couderc , M. Danilov , D. Dannheim , W. Daoud , P. Dauncey , A. David , G. Davies , O. Davignon , E. Day , P. DeBarbaro , F. De Guio , C. de La Taille , M. De Silva , P. Debbins , M. M. Defranchis , E. Delagnes , J. M. Deltoro Berrio , G. Derylo , P. G. Dias de Almeida , D. Diaz , P. Dinaucourt , J. Dittmann , M. Dragicevic , S. Dugad , F. Dulucq , I. Dumanoglu , V. Dutta , S. Dutta , M. Dünser , J. Eckdahl , T. K. Edberg , M. El Berni , F. Elias , S. C. Eno , Yu. Ershov , P. Everaerts , S. Extier , F. Fahim , C. Fallon , G. Fedi , B. A. Fontana Santos Alves , E. Frahm , G. Franzoni , J. Freeman , T. French , P. Gandhi , S. Ganjour , X. Gao , A. Garcia-Bellido , F. Gastaldi , Z. Gecse , Y. Geerebaert , H. Gerwig , O. Gevin , S. Ghosh , A. Gilbert , W. Gilbert , K. Gill , C. Gingu , S. Gninenko , A. Golunov , I. Golutvin , T. Gonzalez , N. Gorbounov , L. Gouskos , A. B. Gray , Y. Gu , F. Guilloux , Y. Guler , E. Gülmez , J. Guo , E. Gurpinar Guler , M. Hammer , H. M. Hassanshahi , K. Hatakeyama , A. Heering , V. Hegde , U. Heintz , N. Hinton , J. Hirschauer , J. Hoff , W. -S. Hou , X. Hou , H. Hua , J. Incandela , A. Irshad , C. Isik , S. Jain , H. R. Jheng , U. Joshi , V. Kachanov , A. Kalinin , L. Kalipoliti , A. Kaminskiy , A. Kapoor , O. Kara , A. Karneyeu , M. Kaya , O. Kaya , A. Kayis Topaksu , A. Khukhunaishvili , J. Kiesler , M. Kilpatrick , S. Kim , K. Koetz , T. Kolberg , O. K. Köseyan , A. Kristić , M. Krohn , K. Krüger , N. Kulagin , S. Kulis , S. Kunori , C. M. Kuo , V. Kuryatkov , S. Kyre , Y. Lai , K. Lamichhane , G. Landsberg , C. Lange , J. Langford , M. Y. Lee , A. Levin , A. Li , B. Li , J. H. Li , Y. y. Li , H. Liao , D. Lincoln , L. Linssen , R. Lipton , Y. Liu , A. Lobanov , R. -S. Lu , M. Lupi , I. Lysova , A. -M. Magnan , F. Magniette , A. Mahjoub , A. A. Maier , A. Malakhov , S. Mallios , I. Mandjavize , M. Mannelli , J. Mans , A. Marchioro , A. Martelli , G. Martinez , P. Masterson , B. Meng , T. Mengke , A. Mestvirishvili , I. Mirza , S. Moccia , G. B. Mohanty , F. Monti , I. Morrissey , S. Murthy , J. Musić , Y. Musienko , S. Nabili , A. Nagar , M. Nguyen , A. Nikitenko , D. Noonan , M. Noy , K. Nurdan , C. Ochando , B. Odegard , N. Odell , H. Okawa , Y. Onel , W. Ortez , J. Ozegović , S. Ozkorucuklu , E. Paganis , D. Pagenkopf , V. Palladino , S. Pandey , F. Pantaleo , C. Papageorgakis , I. Papakrivopoulos , J. Parshook , N. Pastika , M. Paulini , P. Paulitsch , T. Peltola , R. Pereira Gomes , H. Perkins , P. Petiot , T. Pierre-Emile , F. Pitters , E. Popova , H. Prosper , M. Prvan , I. Puljak , H. Qu , T. Quast , R. Quinn , M. Quinnan , M. T. Ramos Garcia , K. K. Rao , K. Rapacz , L. Raux , G. Reichenbach , M. Reinecke , M. Revering , A. Roberts , T. Romanteau , A. Rose , M. Rovere , A. Roy , P. Rubinov , R. Rusack , V. Rusinov , V. Ryjov , O. M. Sahin , R. Salerno , A. M. Sanchez Rodriguez , R. Saradhy , T. Sarkar , M. A. Sarkisla , J. B. Sauvan , I. Schmidt , M. Schmitt , E. Scott , C. Seez , F. Sefkow , S. Sharma , I. Shein , A. Shenai , R. Shukla , E. Sicking , P. Sieberer , P. Silva , A. E. Simsek , Y. Sirois , V. Smirnov , U. Sozbilir , E. Spencer , A. Steen , J. Strait , N. Strobbe , J. W. Su , E. Sukhov , L. Sun , D. Sunar Cerci , C. Syal , B. Tali , C. L. Tan , J. Tao , I. Tastan , T. Tatli , R. Thaus , S. Tekten , D. Thienpont , E. Tiras , M. Titov , D. Tlisov , U. G. Tok , J. Troska , L. -S. Tsai , Z. Tsamalaidze , G. Tsipolitis , A. Tsirou , N. Tyurin , S. Undleeb , D. Urbanski , V. Ustinov , A. Uzunian , M. Van de Klundert , J. Varela , M. Velasco , O. Viazlo , M. Vicente Barreto Pinto , P. Vichoudis T. Virdee , R. Vizinho de Oliveira , J. Voelker , E. Voirin , M. Vojinovic , A. Wade , C. Wang , F. Wang , X. Wang , Z. Wang , Z. Wang , M. Wayne , S. N. Webb , A. Whitbeck , D. White , R. Wickwire , J. S. Wilson , D. Winter , H. y. Wu , L. Wu , M. Wulansatiti Nursanto , C. H Yeh , R. Yohay , D. Yu , G. B. Yu , S. S. Yu , C. Yuan , F. Yumiceva , I. Yusuff , A. Zacharopoulou , N. Zamiatin , A. Zarubin , S. Zenz , A. Zghiche , H. Zhang , J. Zhang , Y. Zhang , Z. Zhang

Two finely segmented and very compact calorimeters are foreseen for the instrumentation of the very forward region of the ILC and the CLIC detectors; a luminometer to measure the rate of low angle Bhabha scattering events with a precision…

Instrumentation and Detectors · Physics 2011-04-22 Iftach Sadeh

India-based Neutrino Observatory (INO) is a multi-institutional facility, planned to be built up in South India. The INO facility will host a 51 kton magnetized Iron CALorimeter (ICAL) detector to study atmospheric muon neutrinos. Iron…

Instrumentation and Detectors · Physics 2014-12-17 Daljeet Kaur , Ashok Kumar , Ankit Gaur , Purnendu Kumar , Md. Hasbuddin , Swati Mishra , Praveen Kumar , Md. Naimuddin

A basic prototype for an analog hadron calorimeter for a future linear collider detector is currently being realized by the CALICE collaboration. The aim is to show the feasibility to build a realistic detector with fully integrated readout…

Instrumentation and Detectors · Physics 2019-08-14 Mark Terwort

The CALICE Semi-digital hadronic calorimeter built in 2011, was installed and tested during two periods of two weeks each in 2012 at CERN SPS facilities. The detector has more than 450000 channels with a semi-digital readout distributed on…

Instrumentation and Detectors · Physics 2019-08-16 Y. Haddad

Precision physics at future multi-TeV lepton colliders such as CLIC requires excellent jet energy resolution. The detectors need deep calorimeter systems to limit the energy leakage also for very highly energetic particles and jets. At the…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

Two different technologies are considered for the Beam Calorimeters of the ILC detector. Simulation studies of the performance have been done for a diamond-tungsten sandwich calorimeter and for a homogeneous heavy element crystal…

Instrumentation and Detectors · Physics 2007-05-23 R. Dollan , Ch. Grah , E. Kuznetsova , W. Lange , W. Lohmann , A. Stahl , K. Afanaciev , V. Drugakov , I. Emeliantchik

A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…

Instrumentation and Detectors · Physics 2010-07-16 Adil Khan

The CALICE collaboration is presently constructing a test hadron calorimeter (HCAL) with 7620 scintillator tiles read out by novel photo-detectors - Silicon Photomultipliers (SiPMs). This prototype is the first device which uses SiPMs on a…

Instrumentation and Detectors · Physics 2008-11-26 M. Danilov